1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – FIGURES; No. Description Page; TABLE OF CONTENTS
  • Page 3 – MUST; Unitary Products Group; INSTALLATION; Voltage Variation; - UNIT APPLICATION DATA
  • Page 4 – - RECOMMENDED DRAIN PIPING
  • Page 6 – - TYPICAL FIELD WIRING; CONTROL WIRING; POWER WIRING; C O O L I N G / H E A T I N G ( E L E C T R O N I C T H E R M O S T A T )
  • Page 7 – REAR VIEW; DETAIL “A”
  • Page 8 – ELECTRIC HEATERS; - ENTHALPY SET POINT ADJUSTMENT; TABLE 3
  • Page 9 – TABLE 4
  • Page 10 – TABLE 5
  • Page 11 – TABLE 6
  • Page 12 – NOTE: Prior to each cooling season, the crankcase heater; COOLING SEQUENCE OF OPERATION; WITH POWER TO UNIT AND THERMOSTAT IN THE; OPERATION; - HEAT ANTICIPATOR SETTING
  • Page 13 – MOTOR PULLEY ADJUSTMENT; CAUTION; - PRESSURE DROP ACROSS A DRY
  • Page 14 – SECURE OWNER'S APPROVAL; perature settings within the limitations of the system.; MAINTENANCE; NORMAL MAINTENANCE; CAUTION: Prior to any of the following maintenance proce-
Loading the manual

GENERAL

YORK Model DEE units are single package air conditioners

designed for outdoor installation on a rooftop or a slab. Electric

heaters are available as field-installed accessories.

The units are completely assembled on rigid, permanently

attached base rails. All piping, refrigerant charge, and electrical

wiring is factory-installed and tested. The units require only

electric power and duct connections at the point of installation.

The electric heaters have nickel-chrome elements and utilize

single point power connection.

INSPECTION

As soon as a unit is received, it should be inspected for possible

damage during transit. If damage is evident, the extent of the

damage should be noted on the carrier's freight bill. A separate

request for inspection by the carrier's agent should be made in

writing. Refer to Form 50.15-NM for additional information.

REFERENCE

Additional information on the design, installation, operation and

service of this equipment is available in the following reference

forms:

55.70-N1

-General Installation

55.70-N2

-Pre-start & Post-start Check List

530.18-N1.2V -Economizer Accessory

530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%

530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%

530.18-N1.12V -Motorized Outdoor Air Damper Accy.

530.18-N1.8V -Coil Guard

530.18-N7.1V -Electric Heater Accessory

530.18-N7.2V -Fuse Block Accessory

690.15-N25V

-Low Ambient to 0

°

F

Renewal Parts:

Refer to Parts Manual for complete listing of replacement

parts on this equipment.

All forms referenced in this instruction may be ordered from:

Standard Register

Toll Free Tel: 877-318-9675/Fax. 877-379-7920

APPROVALS

Design certified by U.L. and C.G.A. as follows:

1. For use as a cooling only unit or cooling unit with electric heat.

2. For outdoor installation only.

3. For installation on combustible material.

®

SUNLINE 2000

ELECTRIC / ELECTRIC

SINGLE PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTION

Supersedes: 035-12046-002-A-0302

035-12046-003-A-0204

Installer should pay particular attention to the words:

NOTE, CAUTION

and

WARNING

. Notes are intended to clarify or

make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that per-

sonal injury and/or equipment damage may result if installation procedure is not handled properly.

MODELS D1EE 048 & 060

and D2EE 036 (11 SEER)

CAUTION

T H E E N C LO SE D IN S TA LLA TIO N IN S TR U C TIO N S A N D A N Y A P PLIC A B LE

LO C AL, ST AT E, A N D N AT IO N A L C O D E S IN C LU D IN G , B U T N O T LIM IT ED

TO , BU ILD IN G , ELE C TR IC A L, AN D M E C H AN IC A L C O D E S .

T H IS P R O D U C T M U S T B E IN S T A L L E D IN S T R IC T C O M P LIA N C E W IT H

WARNING

O P E R A T IO N O F T H E P R O D U C T C O U L D C A U S E P E R S O N A L IN J U R Y

O R P R O P E R T Y D A M A G E .

IN C O R R E C T IN S TA LLAT IO N M AY C R E A TE A C O N D IT IO N W H E R E TH E

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FIGURES; No. Description Page; TABLE OF CONTENTS

035-12046-003-A-0204 2 Unitary Products Group General................................................................................1Inspection ............................................................................1Reference .......................................................................

Page 3 - MUST; Unitary Products Group; INSTALLATION; Voltage Variation; - UNIT APPLICATION DATA

LIMITATIONS These units must be installed in accordance with the current edition of the following national and local safety codes:In USA: 1. National Electrical Code ANSI/NFPA No. 70. 2. Local electric utility requirements. In Canada: 1. Canadian Electrical Code C22.1. 2. Canadian Installation Codes...

Page 4 - - RECOMMENDED DRAIN PIPING

kept clean or replaced with same size and type. Dirty filters will reduce the capacity of the unit and will result in frosted coils or safety shutdown. Minimum filter area and required sizes are shown in Table 2. CONDENSATE DRAIN Plumbing must conform to local codes. Use a sealing compound on male p...