York CU060 - Manual

York CU060

York CU060 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; LIST OF FIGURES
  • Page 3 – These ì cooling onlyî units can be applied with:; GENERAL
  • Page 4 – Cooling performance is rated at 80; Model
  • Page 7 – Values include pressure drop from wet coil and clean filters.
  • Page 9 – TABLE 7: WATERSIDE PRESSURE DROP - CU MODELS
  • Page 10 – TABLE 8: WATER PRESSURE DROP DATA - CH MODELS
  • Page 11 – TABLE 9: COOLING PERFORMANCE DATA - CH 5-10 TON HORIZONTAL MODELS
  • Page 12 – TABLE 10: COOLING PERFORMANCE DATA - CU 5-20 TON VERTICAL MODELS
  • Page 13 – TABLE 11: COOLING PERFORMANCE DATA - CU 300 25 TON VERTICAL MODELS
  • Page 14 – TABLE 14: STANDARD MOTORS CH 5-10 TON MODELS; NOTE: Single Phase unit found in smaller cabinet data 1-5 ton.; MODEL
  • Page 15 – FIGURE 1 - DIMENSIONAL DATA - CH 5 TON HORIZONTAL MODEL
  • Page 18 – FIGURE 5 - DIMENSIONAL DATA - CU 15 TON VERTICAL MODEL
  • Page 19 – FIGURE 6 - DIMENSIONAL DATA - CU 20 TON VERTICAL MODEL
  • Page 20 – FIGURE 7 - DIMENSIONAL DATA - CU 25 TON VERTICAL MODEL
  • Page 21 – SUPPLY AIR/RETURN AIR; either front or rear of the unit.; FIGURE 8 - SUPPLY AIR/RETURN AIR CONFIGURATION
  • Page 22 – FIGURE 9 - HOT WATER & STEAM HEATING COILS DIMENSIONAL DATA; Hot Water and Steam Heating Coil Dimensions (Inches)
  • Page 23 – FIGURE 10 - HOT WATER & STEAM HEATING COILS PERFORMANCE DATA; Steam Coil Performance @ 2 PSIG; Hot Water Coil Performance
  • Page 24 – FIGURE 11 - TYPICAL WATER-SIDE ECONOMIZER PHYSICAL CONFIGURATION
  • Page 25 – FIGURE 12 - WATER-SIDE ECONOMIZER PIPING SCHEMATIC
Loading the manual

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

036-21217-001-B-1203

®

MODELS: CH060 - 5-10 TONS

HORIZONTAL

MODELS: CU060 - 300 5-25 TONS

VERTICAL

SINGLE PACKAGE AIR

CONDITIONING

WATER COOLED

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; LIST OF FIGURES

036-21217-001-B-1203 2 Unitary Products Group TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3APPLICATION FLEXIBILITY . . . . . . . . . . . . . . . . . . . . . . . 3CABINET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 3 - These ì cooling onlyî units can be applied with:; GENERAL

036-21217-001-B-1203 Unitary Products Group 3 DESCRIPTION These units are completely assembled, piped, wired, charged and tested at the factory and are shipped ready for immediate installation. Only the power supply wiring, the thermostat wir-ing, the condenser water piping, the condensate drain pip...

Page 4 - Cooling performance is rated at 80; Model

036-21217-001-B-1203 4 Unitary Products Group NOTE: Cooling performance is rated at 80 ∞ F dry bulb 67 ∞ F wet bulb entering air temperature, CFM listed, 85 ∞ F entering 95 ∞ F leaving water temperature, and water flow rate listed. Gross capacity does not include the effect of evapora- tor fan motor...

Other York Models

All York Other