York 291627-YTG-B-0807 - Manual

York 291627-YTG-B-0807

York 291627-YTG-B-0807 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; LIST OF FIGURES
  • Page 3 – DESCRIPTION
  • Page 4 – FIELD-INSTALLED ACCESSORIES
  • Page 5 – FIGURE 2 - UNIT COMPONENT LOCATION
  • Page 6 – TABLE 1: PHYSICAL DATA
  • Page 8 – ALL SENSIBLE CAPACITY
  • Page 9 – TABLE 4: DNH036 COOLING CAPACITIES - 3 TON
  • Page 11 – TABLE 6: DNH048 COOLING CAPACITIES - 4 TON
  • Page 12 – TABLE 7: DNH060 COOLING CAPACITIES - 5 TON
  • Page 13 – TABLE 8: SIDE SUPPLY AIR BLOWER PERFORMANCE - 208 VOLT
  • Page 15 – TABLE 10: BOTTOM SUPPLY AIR BLOWER PERFORMANCE - 208 VOLT
  • Page 16 – TABLE 11: BOTTOM SUPPLY AIR BLOWER PERFORMANCE - 230 & 460 VOLTS
  • Page 17 – FIGURE 3 - TYPICAL FIELD CONTROL WIRING DIAGRAM; PROGRAMMABLE; THERMOSTAT
  • Page 18 – TABLE 14: ELECTRICAL DATA
  • Page 19 – TABLE 15: UNIT DIMENSIONS FRONT; TABLE 16: UNIT MINIMUM CLEARANCES
  • Page 21 – FIGURE 8 - TYPICAL SLAB ON GROUND INSTALLATION
  • Page 22 – FIGURE 10 - TYPICAL DUCT APPLICATIONS
  • Page 23 – FIGURE 12 - ROOF CURB DIMENSIONS
  • Page 28 – Motors inherently protected.; FIGURE 18 - TYPICAL WIRING DIAGRAM LEGEND; Open all disconnects before servicing this unit.
  • Page 29 – MECHANICAL SPECIFICATIONS; GENERAL; UNIT CABINET; LOW SPEED
  • Page 30 – REFRIGERANT COMPONENTS; Refrigerant Circuit and Refrigerant Safety Components:; UNIT OPERATING CHARACTERISTICS
Loading the manual

291627-YTG-B-0807

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TECHNICAL GUIDE

AFFINITY™ SERIES

SINGLE PACKAGE GAS/ELECTRIC

AIR COOLED AIR CONDITIONERS

2-1/2 THROUGH 5 NOMINAL TON

DNH030 THROUGH 060
UP TO 12.4 SEER

®

ISO 9001

Certified Quality

Management System

FLEXIBLE LIGHT COMMERCIAL UNIT

GENERAL

York

®

Affinity™ Series packaged units are designed to han-

dle applications ranging from residential to light commercial
and any in between. The Affinity™ is a unit that gives you the
flexibility and choices you need in today’s market.

FEATURING

COOLING/GAS HEATING UNITS (NATURAL GAS OR
PROPANE)

LOW PROFILE

QUIET OPERATION

COMMON FOOTPRINT

OPTIONAL SLIDE IN MOTORIZED DAMPERS

OPTIONAL SLIDE IN ECONOMIZERS

OPTIONAL PROPANE CONVERSION KIT

OPTIONAL HIGH ALTITUDE CONVERSION KIT
(NATURAL GAS/PROPANE)

FULL PERIMETER BASE RAILS

BOTTOM AND SIDE UTILITY CONNECTIONS

1” OR 2” CLEANABLE FILTERS STANDARD ON ALL
MODELS

WARRANTY - 3 PHASE

5 year compressor

10 year heat exchanger

1 year other parts

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; LIST OF FIGURES

291627-YTG-B-0807 2 Unitary Products Group TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3STANDARD FEATURES/BENEFITS . . . . . . . . . . . . 3FIELD-INSTALLED ACCESSORIES. . . . . . . . . . . . . 4TYPICAL WIRING DIAGRAM NOTES . . . . . . . . . . 28MECHANICA...

Page 3 - DESCRIPTION

291627-YTG-B-0807 Unitary Products Group 3 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct con-nections are required at the point of installation. The gas-fired heaters have aluminized steel tubular heat exchangers and spark to...

Page 4 - FIELD-INSTALLED ACCESSORIES

291627-YTG-B-0807 4 Unitary Products Group FAN SYSTEM - All models operate over a wide range of design conditions with a 3-speed direct-drive fan motor. These units easily match all types of applications and pro-vides greater on site flexibility to match comfort requirement. SIMPLE CONTROL CIRCUIT -...

Other York Models