- Page 2 – Unitary Products Group; PHYSICAL AND ELECTRICAL DATA - 1 & 3 Phase; MODEL
- Page 3 – COOLING CAPACITY - With Air Handler Coils
- Page 4 – COOLING PERFORMANCE
- Page 5 – ACCESSORIES; Refer to Price Manual for specific model numbers.; Compressor Blanket; provides required; Outdoor Thermostat -; SOUND RATINGS; UNIT MODEL; NOTE: ALL OUTDOOR WIRING MUST
- Page 7 – COOLING PERFORMANCE DATA; AIR CONDITIONER MODEL NO.; CONDENSING; Air Handler
- Page 14 – MATCHING INDOOR COMPNENTS; AIR HANDLERS
- Page 15 – NOTES
036-21103-003 Rev. A (0403)
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
®
TECHNICAL GUIDE
SPLIT-SYSTEM AIR CONDITIONERS
10 SEER 50 H
Z
H*RA018S78 THRU H*RA036S78 (1 PH)
H*RA036S50 THRU H*RA060S50 (3PH)
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
DESCRIPTION
The HRA Series condensing unit is the outdoor part of a ver-
satile system of air conditioning. It is designed to be custom
matched with one of UPG’s complete line of evaporator sec-
tions, each designed to serve a specific function. Matching
Air Handlers are available for upflow, downflow or horizontal
applications to provide a complete system. Electric Heaters
are available if required. Add-On coils are available for use
with upflow, downflow or horizontal furnaces and air handlers.
FEATURES
•
QUALITY CONDENSER COILS -
The coil is constructed
of enhanced copper tube and aluminum fins.
•
COIL PROTECTION -
Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
•
PROTECTED COMPRESSOR -
The compressor is inter-
nally protected against high pressure and temperature.
This is accomplished by the simultaneous operation of
high pressure relief valve and a temperature sensor which
protects the compressor if undesirable operating condi-
tions occur. A liquid line filter-drier further protects the
compressor.
•
DURABLE FINISH -
Cabinet is made of pre-painted steel.
The pre-treated flat galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
•
LOWER INSTALLED COST -
Installation time and costs
are reduced by easy power and control wiring connections.
Discharge line heat exchanger knockouts are provided, if
required. Available in sweat connect models only. The unit
contains enough refrigerant for matching indoor coils and
15 feet of interconnecting piping. The small base dimen-
sion means less space is required on the ground or roof.
•
TOP DISCHARGE -
The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
•
LOW OPERATING SOUND LEVEL -
The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins of
the condenser coil muffle the normal fan motor and com-
pressor operating sounds.
•
LOW MAINTENANCE -
Long life permanently lubricated
motor-bearings need no annual servicing.
•
EASY SERVICE ACCESS -
Fully exposed refrigerant con-
nections, a single panel covering the electrical controls
and the molex plug in the control box connecting the con-
denser fan, make for easy servicing of the unit.
•
SECURED SERVICE VALVES -
Secured re-usable ser-
vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
•
FACTORY TESTED -
to verify system operation and con-
trol functioning before shipment.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
036-21103-003 Rev. A (0403) 2 Unitary Products Group PHYSICAL AND ELECTRICAL DATA - 1 & 3 Phase MODEL H1RA018S78 H1RA024S78 H1RA030S78 H1RA036S78 H1RA036S50 H1RA048S50 H1RA060S50 Unit Supply Voltage 230 – 1 – 50 380/415 – 3 – 50 Normal Voltage Range 1 1. Rated in accordance with ARI Standard 110...
036-21103-003 Rev. A (0403) Unitary Products Group 3 1. TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit. 2. Single phase units require single phase 2HK heaters — Three phase units require three phase 2HK heaters. (29) indicates 460 volt use only. 3. G2FD coils available with a fact...
036-21103-003 Rev. A (0403) 4 Unitary Products Group 1.For condensing unit only. Does not include effect of evaporator motor power or heat. 2.Performance based on 15” superheat and 15" sub-cooling at condensing unit. a.Increase capacity 1% for each 2... increase in sub-cooling. b.Decrease capaci...