Xantrex Freedom SW 2000 - Manual

Xantrex Freedom SW 2000

Xantrex Freedom SW 2000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
Page: / 60

Table of Contents:

  • Page 4 – About This Guide; The following conventions are used in this guide.
  • Page 5 – iii; This; Related Information; Contains statements of avoidance or strict compliance.
  • Page 6 – Important Safety Instructions; The Freedom SW 2000 contains no user-serviceable parts. See; ELECTRICAL SHOCK HAZARD
  • Page 7 – FIRE AND BURN HAZARD
  • Page 8 – Freedom SW 2000 Installation Guide; Precautions When Working With Batteries; Never smoke or allow a spark or flame near the engine or batteries.
  • Page 9 – vii; Precautions When Preparing to Charge; EXPOSURE TO CHEMICALS AND GASES HAZARD; Make sure the area around the battery is well ventilated.; RISK OF DAMAGE TO THE INVERTER/CHARGER; Do not place a battery on top of the inverter/charger.
  • Page 10 – Regulatory; LIMITATIONS ON USE; Do not use in ambulances or other life-saving emergency vehicles.
  • Page 11 – Contents
  • Page 15 – Introduction; This Installation Guide provides:
  • Page 16 – NOTE; Materials List
  • Page 17 – Installation Information; Before You Begin the Installation; Before beginning your installation:; Installation Codes; ABYC A31 - Battery Chargers and Inverters.; ELECTRICAL SHOCK AND FIRE HAZARDS; Disconnect all AC and DC power sources.
  • Page 18 – Planning the Installation; Inverter/Charger Owner’s Guide; Two Key Performance Factors; Size and Length of DC Cables
  • Page 19 – Figure 2; Sample Vehi
  • Page 20 – Wiring and Breakers Blo; For wire and breaker size information:
  • Page 21 – AC Components; AC Input; AC Input Protection
  • Page 22 – Distribution Panels; Table 1; Tested GFCI Models; Manufacturer; Hubbell
  • Page 23 – AC Wiring; Table 2; Input AC Wire Size
  • Page 24 – DC Components; Batteries; Type
  • Page 25 – DC Cabling; Definition; DC Grounding; Table 3; Re
  • Page 26 – Unpacking and Inspecting the Freedom SW 2000 Inverter/Charger; To unpack and inspect:; Freedom SW 2000 Sine Wave Inverter/Charger Owner’s Guide; HEAVY LOAD; Physical Specifications” on page 36)
  • Page 27 – Installation Tools and Materials; Tools; Wire stripper; Materials; DC battery cables sized according to Table 3 on page 11
  • Page 28 – Installing the Inverter/Charger; Overview; Step 1: Choosing a Location for the Inverter/Charger
  • Page 29 – FIRE AND EXPLOSION HAZARD; Ventilated
  • Page 30 – be installed; Orientation
  • Page 31 – Considerations
  • Page 32 – Mounting Orientations; Desktop Mount; IMPORTANT; : This orientation is also
  • Page 33 – Wall Mount DC on Right
  • Page 34 – Step 3: Connecting the AC Input and AC Output Wires; General AC Wiring Considerations; AC and DC Wiring Separation; FIRE, ELECTRICAL SHOCK, AND ENERGY HAZARDS
  • Page 35 – Connecting AC Input Wires; To make the AC input connections:; Install a strain-relief clamp in the AC knockout.; AC Wiring Compartment; EQUIPMENT DAMAGE
  • Page 36 – Neutral to; Connecting AC Output Wires; To make the AC output wiring connections:; Do not connect the output of the inverter to any incoming AC source.
  • Page 37 – Secure the strain-relief clamp on the AC output cable jacket.; Table 4; Output AC Wire Size
  • Page 38 – Step 4: Connecting the DC Cables; DC Connection Precautions; For recommended DC cables and fuse size, see Table 3 on page 11.; Preparing the Cables; To prepare the DC cables:
  • Page 39 – Guidelines for Routing the DC Cables; Follow these guidelines to ensure maximum performance.; ELECTRICAL SHOCK AND FIRE HAZARD
  • Page 40 – Connecting the DC Cables to the Inverter/Charger; To connect the DC cables:; Open the DC disconnect switch or turn off the DC circuit breaker.; FIRE HAZARD
  • Page 41 – at the inverter/charger; Figure 3; DC Cable Conne; Figure 4; DC Terminal Covers
  • Page 42 – To connect the chassis ground:; DC Wiring and DC Grounding; Chassis ground point
  • Page 43 – Mounting Options; You can mount the BTS in one of two ways:; Figure 6; BTS with Cable
  • Page 44 – Mounting to the Negative Battery Terminal; To mount the sensor on the negative battery terminal:; Wait 10 minutes for any explosive battery gases to dissipate.; Figure 7; BTS Mounted on the Negative Battery Terminal
  • Page 45 – Figure 8; Conne
  • Page 46 – Mounting to the Side of the Battery Case; To mount the sensor on the battery case:; Select the battery to be monitored.; Figure 9; BTS Mounted on the Battery Case
  • Page 47 – Step 6: Performing Checks Prior to Initial Start-Up; Chassis and AC grounds are properly installed.
  • Page 48 – Step 7: Testing Your Installation; the Freedom SW 2000 works in invert mode,; Testing in Invert Mode; The inverter will go through a self-test.; Freedom SW 2000 Front Panel
  • Page 49 – Testing in Charge Mode
  • Page 50 – Inverter/Charger Physical Specifications; For complete inverter/charger specifications, refer to the; Table 5; al Spe
  • Page 51 – Battery Information; Battery Bank Sizing; Battery capacity; Battery size or capacity is just as important as the; Estimating Battery Requirements; Calculating Battery Size; Step 2: Calculate Battery Size
  • Page 52 – If you find that the system shuts down when appliances; Table 6; Battery Sizing Example; Appliance
  • Page 53 – Battery Banks; Mixing Batteries; Batteries connected in parallel should be of the same; Battery Bank Sizing Worksheet; Restrictions on Motor Size
  • Page 54 – Battery Sizing Worksheet; Recommended Battery Bank Size in Ah (multiply by 2)
  • Page 55 – Cabling and Hook-up Configurations; Parallel Connection; Batteries Conne
  • Page 56 – Series Connection
  • Page 57 – Series-Parallel Connections; Batteries in Series-Parallel Conne
  • Page 60 – Xantrex Technology Inc.; ustomerservi
Loading the manual

TM

TM

This

g

u

id

e for

u

se by qu

alifi

ed installers only.

Freedom SW 2000
Sine Wave Inverter/Charger

Installation Guide

FREEDOM

SW

2000

1000

800
600
400

30


100
200

Max O

ff

AC Input

Ba

tte

ry T

ype

Sear

ch

Batt

ery Bank

M

ode

Ca

pa

city (

Ah)

AGM/

W

ide

Na

rrow GEL

Flo

oded

Fault kW I

nve

rting

A

Cha

rging

Batt

%

FREEDOM

SW

2000

1000

800
600
400

30


100
200

Max O

ff

AC Input

Ba

tte

ry

Type

Sea

rch

Ba

tte

ry

Bank

M

ode

Capaci

ty (

Ah)

AGM/

W

ide

Na

rro

w GEL

Flo

oded

Fault kW I

nv

erting

A

Cha

rging

Ba

tt

%

FREEDOM

SW

2000

FREEDOM

SW

2000

Date of Manufacture

Serial Number

CAUTION:

To reduce the risk of fire, do not

cover or obstruct ventilation openings. Do not mount
in a zero-clearance compartment. Overheating may
result. Do not expose to rain or spray.

INSTALLATION REQUIREMENTS:

Mount this inverter/charger only in the orientations
specified in the installation guide provided.

WARNING:

Shock hazard. Do not open. No

user serviceable parts. Energized from both AC and
DC sources. Disconnect all sources before servicing.
Use only ground-fault circuit interrupters (GFCI)
specified in the installation guide supplied. Other
types may fail to operate properly when connected

to

this equipment. Refer to manual. Charge only
lead-acid batteries. Other battery types may burst
causing personal injury and damage.

Nominal DC Operating Volta

ge:

12 Vdc

Nominal AC Output Voltage:

120 Vac , 1Ø

Nominal AC Output Frequency:

60 Hz

Max. Continuous AC Output Current:

16.66 A

Max. Operating DC Input

Current:

252 A

Max. Continuous AC Output a

t Nominal DC

Input:

2000 W at 30°C

Max. Output Surge Power (10 s duration):

4000 VA

Max. DC Input Voltage:

15.5 Vdc

Max. A

mbient Temperature:

50°C

Inverter Mode:

Nominal AC Input Voltage:

120 Vac , 60 Hz, 1Ø

Power Factor:

> 0.95

Charging DC Output Voltage R

ange:

11.0 - 16.0 Vdc

Max. Continuous Battery C

harger DC Current at

Nominal AC Input:

100 A

Max. A

C Input Current (charge + pass-through):

48 A rms

Charger Mode:

2000W SINEWA

VE INVER

TER/CHARGER

FSW2000

815-2000

Model
Number

FGA

Number

FREEDOM SW 2000

Designed in Canada

.

Assembled in China.

DANGER:

To reduce the risk of explosion, do not

install in an area in which ignition-protected
euipment is required.

UL 458

CSA 107.1-01

3033614

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - About This Guide; The following conventions are used in this guide.

ii Freedom SW 2000 Installation Guide About This Guide Purpose The purpose of this Installation Guide is to provide procedures for installing the Freedom SW 2000 Inverter/Charger. Scope The guide provides safety guidelines as well as information on installing the inverter/charger. It does not provid...

Page 5 - iii; This; Related Information; Contains statements of avoidance or strict compliance.

975-0527-01-01 iii This g u id e for u se by qu alifi ed installers only. Related Information You can find more information about Xantrex Technology Inc. as well as its products and services at www.xantrex.com . STATEMENT OF HAZARD Contains statements of avoidance or strict compliance. Failure to fo...

Page 6 - Important Safety Instructions; The Freedom SW 2000 contains no user-serviceable parts. See; ELECTRICAL SHOCK HAZARD

iv Freedom SW 2000 Installation Guide Important Safety Instructions IMPORTANT: R EAD AND SAVE THIS I NSTALLATION G UIDE FOR FUTURE REFERENCE . This chapter contains important safety and installation instructions for the Freedom SW 2000 Inverter/Charger (Freedom SW 2000). Each time, before using the ...

Other Xantrex Models

All Xantrex Other