Page 4 - Limited; What does this warranty cover and how long does it last?; This warranty lasts for a Warranty Period of; years; from the date of purchase at; What will Xantrex do?; Toll Free North America:
ii Operating Manual for APG for XT/HPD Series Power Supply Limited Warranty What does this warranty cover and how long does it last? This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your Internal APG Interface card. This war...
Page 5 - Proof of purchase may be in any one of the following forms:; What does this warranty not cover?; another manufacturer
Release 1.0 iii Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repai...
Page 6 - Disclaimer; Product; Exclusions
iv Operating Manual for APG for XT/HPD Series Power Supply Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS,...
Page 7 - Model Number
Release 1.0 v Information WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, UNLESS SPECIFICALLY AGREED TO BY IT IN WRITING, XANTREX a. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION PROVIDED BY IT IN C...
Page 8 - WARNING
vi Operating Manual for APG for XT/HPD Series Power Supply Warnings and Cautions Warnings and cautions are defined and formatted in this manual as shown below. Power Supply Safety WARNING Describes a potential hazard which could result in injury or death, or, a procedure which, if not performed corr...
Page 9 - About This Manual; Main Sections; Section 1 Features and Specifications; Describes the power supply and lists; Section 2 Installation and Configuration; Goes through basic setup; Section 3 Operation; Details information on remote programming, indicators; Manual Revisions
Release 1.0 vii About This Manual This manual is for the internal APG (Analog Programming) interface card for the XT and HPD Series DC output power supplies. This manual provides you with descriptions and specifications, user options, and configuration instructions which enable you to manage the pow...
Page 11 - Contents; Features and
Release 1.0 ix Contents About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Section 1. Features and Specifications Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 13 - Section 1. Features and Specifications; Description
Release 1.0 11 Section 1. Features and Specifications Description The Analog Programming (APG) Interface is an internal option card for analog programming of XT and HPD Series DC power supplies with a 0-10Vdc programming source or a 0-10k Ω resistance. A 25-pin female DSUB connector on the unit's re...
Page 15 - Section 2. Installation and Configuration; Introduction; Your local; Initial Inspection; On first receiving your unit, perform a quick physical check.; CAUTION
Release 1.0 13 Section 2. Installation and Configuration Introduction We usually install the APG interface in a power supply at the factory. Your local distributor or service center can also install the interface, especially for use in a previously-purchased supply already on site. Initial Inspectio...
Page 16 - Configuring; Front panel; XT/HPD Front Panel with APG Interface Installed
Section 2. Installation and Configuration Configuring 14 Operating Manual for APG for XT/HPD Series Power Supply Configuring Configure and adjust the analog programming interface installed in your XT or HPD DC power supply as indicated in this section. The front panel LEDs indicate when V or I progr...
Page 17 - Rear Panel; Setting Function
Section 2. Installation and Configuration Configuring Release 1.0 15 Rear Panel Figure 2.2 XT/HPD Rear Panel with APG Interface Rear Panel Switch (S1) Defaults Table 2.1 Rear Panel Switch S1 Default Settings Default: Local control (all switches OPEN). Setting Function S1-1 TTL Shutdown Logic Select ...
Page 18 - Rear Panel J5 Connector; source must also be an isolated source.; J5 Connector; J5 Connector Pin Assignments
Section 2. Installation and Configuration Rear Panel J5 Connector 16 Operating Manual for APG for XT/HPD Series Power Supply Rear Panel J5 Connector Make analog interface connections via the rear panel 25-pin female DSUB connector designated J5. To provide the lowest noise performance, we recommend ...
Page 19 - Calibration Adjustment; APG Interface Calibration Adjustment Locations
Section 2. Installation and Configuration Calibration Adjustment Release 1.0 17 Calibration Adjustment You can access most calibration potentiometers through the top of the unit, see Figure 2.3. The exceptions are Voltage Program OFFSET and RANGE which are on the unit's rear panel which can be seen ...
Page 21 - Remote Programming; Programming
Release 1.0 19 Section 3. Operation Remote Programming Remote programming allows control of the power supply's output voltage and/or current limit to shift from local operation at the front panel voltage and current controls to external analog input sources. As you vary the programming source, the p...
Page 22 - to vary the power supply output from 0-100%
Section 3. Operation Remote Programming 20 Operating Manual for APG for XT/HPD Series Power Supply 3. Vary the external voltage from 0-10Vdc to cause the power supply output to vary from 0-100% of rated output voltage. You may set the power supply's output current limit using another source or the f...
Page 23 - to vary the power supply current limit from; Programming with a Fixed +10V Reference; = programmed output of power supply; = rated maximum output of power supply
Section 3. Operation Remote Programming Release 1.0 21 Programming Output Current with a 0-10k Resistance 1. Select remote current programming by external resistance by moving the rear panel switch S1-3 (remote current program select) to the ON (closed) position. Or, connect J5 pin 8 (remote current...
Page 24 - Readback and Status Indicators; active low open collector
Section 3. Operation Readback and Status Indicators 22 Operating Manual for APG for XT/HPD Series Power Supply Readback and Status Indicators Voltage and Current Readback Voltage Readback • Connect a meter between J5 connector pin 19 (voltage readback) and either pin 4 or 5 (program return). Range: ...
Page 26 - TTL Shutdown; Connect the signal source between J5 connector pins 15 (TTL; TTL Signal Level
Section 3. Operation TTL Shutdown 24 Operating Manual for APG for XT/HPD Series Power Supply TTL Shutdown TTL Shutdown allows the output of the power supply to be disabled by a logic level signal. This input is optically isolated from the power supply output and will withstand a highpot test potenti...
Page 27 - Tracking; potentiometers. See “Calibration Adjustment” on page 17.; Master/Slave Tracking Configuration
Section 3. Operation Tracking Release 1.0 25 Tracking For tracking +/- outputs, use the following set-up: • Set slave unit rear panel switch S1-5 (remote voltage program select) and switch S1-6 (tracking select) to ON (closed). • Connect master return (J5 connector pins 12, 13, or 24) to slave +OUT ...
Page 30 - Xantrex Technology Inc.
Xantrex Technology Inc. 8999 Nelson Way Burnaby, British Columbia Canada V5A 4B5604 422 8595 Tel604 421 3056 Fax800 667 8422 Toll Free North [email protected] TM-5A6H-01XN PRINTED IN CANADA