Page 2 - MACHINE DATA LOG; YOUR DEALER
MACHINE DATA LOG D100 86038260 05/21/07 2 For the name and address of your dealer contact: Windsor Industries YOUR DEALER Name: __________________________________________________________________________________________________ Address: ________________________________________________________________...
Page 3 - TABLE OF CONTENTS; OPERATIONS
TABLE OF CONTENTS D100 86038260 05/21/07 3 Machine Data Log .........................................2 Table of Contents..........................................3 HOW TO USE THIS MANUAL How to use this Manual.................................1-1 SAFETY Important Safety Instructions ....................
Page 4 - HOW TO USE THIS MANUAL
HOW TO USE THIS MANUAL D100 86038260 05/21/07 1-1 This manual contains the following sections: - HOW TO USE THIS MANUAL - SAFETY - OPERATIONS - MAINTENANCE - PARTS LIST The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts. Parts may be ...
Page 5 - SAFETY INSTRUCTIONS; IMPORTANT SAFETY INSTRUCTIONS; When using an electrical appliance, basic precaution; READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.; SAVE THESE INSTRUCTIONS
SAFETY INSTRUCTIONS D100 86038260 05/21/07 2-1 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use. To reduce the risk of fire, electri...
Page 6 - HAZARD INTENSITY LEVEL; WARNING; WARNING; WARNING; CAUTION
HAZARD INTENSITY LEVEL D100 86038260 05/21/07 2-2 The following symbols are used throughout this guide as indicated in their descriptions: HAZARD INTENSITY LEVEL There are three levels of hazard intensity identified by signal words - WARNING and CAUTION and FOR SAFETY. The level of hazard intensity ...
Page 7 - GROUNDING INSTRUCTIONS
GROUNDING INSTRUCTIONS D100 86038260 05/21/07 2-3 THIS PRODUCT IS FOR COMMERCIAL USE ONLY. ELECTRICAL: In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below...
Page 8 - TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS D100 86038260 05/21/07 3-1 ITEM DIMENSION/CAPACITY Electrical 115V, 60Hz, 15A Electric Vacuum Motor 2HP, 3 Stage Waterlift 137” (348 cm) Solution Pump 100 psi Solution Capacity 17 gallons (64.3 l) Recovery Capacity 15 gallons (56.75 l) Dimensions - Weight 69 lbs. (31.4 kg) D...
Page 9 - before; GENERAL INFORMATION:; For hose fitting lubrication
OPERATIONS D100 86038620 05/21/07 3-2 CARPET INSPECTION: Determine precisely what areas you are going to clean. Note problem areas in the carpet or tack strip. Look for loose carpet, heavily damaged areas, discolored stains, or grease spots that will require prespotting. Note the carpet type. Check ...
Page 10 - MAINTENANCE
MAINTENANCE D100 86038620 05/21/07 4-1 DAILY MAINTENANCE: (At the end of each working day) : 1) Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water. 2) Vacuum out the solution tank . 3) Rinse tank with fresh water. Periodically inspect the recovery...
Page 11 - VACUUM MOTOR REPLACEMENT
MAINTENANCE D100 86038260 05/21/07 4-2 ! WARNING ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Locate the vacuum motor wires and disconnect at the connector. 4. Remove the v...
Page 12 - SOLUTION PUMP REPLACEMENT
MAINTENANCE D100 86038260 05/21/07 4-3 ! WARNING: SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the machine. 2. Remove recovery tank. 3. Remove solution hoses from fittings in pump. 4. Remove the (2) screws that fasten the pump to the frame. 5. Reverse process to install pump. Pump H...
Page 13 - TROUBLESHOOTING
TROUBLESHOOTING D100 86038260 05/21/07 4-4 PROBLEM . CAUSE SOLUTION No power to machine. Faulty power cord. Replace. Dead electrical circuit. Check building circuit breaker or fuse box. Electrical shock. Equipment not grounding. Follow grounding instructions exactly. Receptacle not grounded. Contact...
Page 14 - WIRING DIAGRAM
Page 16 - RECOVERY TANK ASSEMBLY
RECOVERY TANK ASSEMBLY D100 86038260 05/21/07 5-1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 14 15 16 17 22 23 12 23 24 18 19 20 21
Page 18 - SOLUTION TANK ASSEMBLY
SOLUTION TANK ASSEMBLY D100 86038260 07/09/08 5-3 1 2 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 53A 31 17 9 30 33 30 31 9 42 36 37 38 40 39 41 42 43 44 45 46 47 48 49 50 51 34 35 46 3 4 52 55 54 56 22 57 32 53B 59 9 42
Page 20 - SUGGESTED SPARE PARTS
SUGGESTED SPARE PARTS D100 86038260 07/09/08 5-5 PART NO. PRV NO. DESCRIPTION SERIAL NO. FROM NOTES 86135320 140687 BRUSH SET, 120V VAC WINDSOR * 86135300 140676 BRUSH SET, 120V 3ST VAC AMETEK 86031640 85049 VAC MOTOR ASM, 115 3ST D/B 86031590 65215 PUMP ASM, 100 PSI 86256960 72142 SWITCH, SPST 15A ...