White Rodgers 36h - Manual
White Rodgers 36h – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Parts and Accessories:; SPECIFICATIONS; PRECAUTIONS
- Page 4 – MAIN PIPING CONNECTIONS; NOTE; Figure; NOTE; INSTALLATION
- Page 5 – SYSTEM WIRING; FOR TERMINAL IDENTIFICATION.; and; • For proven/intermittent pilot gas applications
- Page 7 – OUTLET PRESSURE ADJUSTMENT; ADJUSTMENT; PRESSURE REGULATOR
- Page 8 – LIGHTING INSTRUCTIONS
- Page 9 – configurés pour les applications au gaz naturel sans; Robinet de gaz universel de rechange pour allumage électronique; INSTRUCTIONS D’INSTALLATION; Spécifications; Gaz de pétrole liquéfiés; SPÉCIFICATIONS
- Page 10 – Pièces et accessoires :; • Deux trousses
- Page 12 – PRINCIPAUX RACCORDS DE TUYAUX; approuvé pour tous les; CONVERSION AU GPL; REMARQUE
- Page 13 – CÂBLAGE DU SYSTÈME; • Pour les applications au gaz sans pilote HSI; figurent sur le contrôleur de gaz.; . Caractéristiques et identification des bornes; • Pour les applications au gaz avec pilote
- Page 15 – étages; Pour accroître la; AJUSTEMENT
- Page 16 – Assurez-vous de vérifier près du plancher parce; • Ne tentez pas d’allumer quelque appareil; appelez un technicien qualifié. La force excessive; AVERTISSEMENT; figurent ci-dessus dans l’étiquette. Si vous ne sentez; INSTRUCTIONS D’UTILISATION; INSTRUCTIONS D’ALLUMAGE
- Page 17 – principal y válvulas redundantes que controlan el flujo; Válvula de gas universal de encendido electrónico de repuesto; INSTRUCCIONES DE INSTALACIÓN; Especificaciones; Bajo; ESPECIFICACIONES
- Page 18 – PRECAUCIONES
- Page 19 – ADVERTENCIA; • No ajuste excesivamente la tubería al control (
- Page 20 – INSTALACIÓN; CONEXIONES DE LAS TUBERÍAS; CONVERSIÓN PARA GAS DE; NOTA
- Page 21 – CONEXIONES DEL SISTEMA; Estas válvulas se envían con un puente externo; con el voltaje y la frecuencia que se indican en el control de gas.; . Características e identificación de terminales; • Para aplicaciones que requieran gas con piloto/
- Page 22 – Figura
- Page 23 – AJUSTE DE PRESIÓN DE SALIDA; la presión del piloto; AJUSTE; AJUSTE DEL REGULADOR; Gas natural: Modelos de dos etapas - La presión de
- Page 24 – POR SU SEGURIDAD LEA ANTES DE USAR; INSTRUCCIONES DE ENCENDIDO
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
The
36
H series gas valve has redundant and main
solenoid valves that control gas flow to the main
burners, a pressure regulator to maintain a constant
outlet pressure, and a two position on/off switch for
electrical shutoff. The valves are shipped from the fac-
tory set for natural gas non-piloted applications.
See instructions in this document for modifications
required if the valve is to be installed on an LP gas
and/or piloted gas application.
36
H SERIES
Universal Replacement Electronic Ignition Gas Valve
INSTALLATION INSTRUCTIONS
CONTENTS
Description .....................................................
1
Specifications .................................................
1
Precautions .....................................................
3
Installation ......................................................
4
System Wiring
Adjustment .....................................................
7
Pressure Regulator Adjustment
Lighting Instructions ........................................
8
Contents French .............................................
9
Contents Spanish ..........................................
17
T
ype of Gas: ...................... Natural Gas
Ambient Temperature: ....
-40°
to
175°F
Pressure Rating: ...............
14”
W.C. (
1⁄2
PSI) max.
Voltage: ............................
24
VAC
Frequency: .......................
50/60
Hz
Current: ............................ Single Stage -
.410A
Two-Stage -
.540A
Model
No.
No. of
Stages
Open
Characteristics
Proven/
Intermittent
Pilot
HSI DSI
36
H
32
1
Fast
Yes
Yes Yes
36
H
33
1
Slow
Yes
Yes Yes
36
H
64
2
Fast
Yes
Yes Yes
36
H
65
2
Slow
Yes
Yes Yes
Pressure Regulator Adjustment Range ( in W.C.)
Single
Stage
Two Stage
Low
High
Min Diff.
Low to High
Natural Gas
2.5 - 5.0
1.0 - 3.5
2.5 - 5.0
1.5
LP Gas
5.0 - 12.0
4.0 - 9.5
8.0 - 12.0
2.5
PIPE SIZES/CAPACITIES
Pipe Sizes
Available (inches)
Capacity (BTU/hr) at
1
” W.C.
pressure drop across valve
AGA Std. Nat. Gas
(
1,000
btu/ cu. ft.)
LP. Gas
(
2,500
btu/cu. ft.)
3/4” x 3/4”
NPT
300,000
486,000
1/2” x 3/4”
NPT
260,000
421,000
SPECIFICATIONS
DESCRIPTION
www.white-rodgers.com
www.emersonclimate.com
PART NO.
37-7336A
1219
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 360˚ MOUNTING POSITIONS: Upright, or 0° to 90° from upright UPRIGHT LEFT or RIGHT INLET BOSS VERTICAL Figure 1 . Gas Valve Mounting Positions REGULATOR COVER SCREWS (REG. ADJ. BENEATH THESE SCREWS) TERMINAL – M (MAIN) TERMINAL – P (PILOT/REDUNDANT) TERMINAL – C (COMMON) TERMINAL – HI ( 2 ND STAGE ...
4 INSTALLATION MAIN PIPING CONNECTIONS NOTE Refer to warnings and cautions on page 3 before attempting installation. All piping must comply with local codes, ordinances, and/or national fuel gas codes. 1. Turn off electrical power to the system at the fuse box or circuit breaker. Also turn off the m...
5 SYSTEM WIRING REFER TO AND FOLLOW THE APPLIANCE MAN-UFACTURER’S WIRING DIAGRAM. REFER TO FIG. 4 AND 5 FOR TERMINAL IDENTIFICATION. These valves are shipped with an external jumper installed for non-piloted gas applications.• For non-piloted gas applications HSI and DSI, connect common wire to (C) ...