White Rodgers 36C - Manual

White Rodgers 36C

White Rodgers 36C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – control and may cause shock or fire hazard.; PRECAUTIONS; CAUTION; WARNING
  • Page 3 – PILOT GAS CONNECTION; INSTALLATION; Pilot gas; Figure 3; NOTE; SYSTEM WIRING
  • Page 4 – Figure 5
  • Page 5 – Figure 7
  • Page 6 – Figure 9
Loading the manual

36C

Cycle Pilot Gas Valve

PART NO. 37-6517A

0618

INSTALLATION INSTRUCTIONS

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

The 36C cycle pilot gas valves with redundant pilot sole-
noid main gas regulator, integral gas pressure switch and
electrical connection on the gas valve for mercury flame
sensor connection.

SPECIFICATIONS

LP

Internal

Regulator

Conversion

Reducer

Inlet

Wiring

Model

Coil

Gas

Pipe

Opening

Regulator Adjustment Convertible

Kit

Line

Flow

Bushing

Pressure

Side

See

Number

Voltage

Type

Size

Characteristic

Setting

Range

Nat./LP

Included

Interrupter Direction

Kit

Tap

Taps

Figure

36C84-912

24 VAC Natural

3

/

4

x

3

/

4

Fast Open

3.5

2.5

–5.0

Yes

Yes

No

Str. Thru

Yes

Yes

No

5

36C84-913

24 VAC Natural

3

/

4

x

3

/

4

Fast Open

3.5

2.5

–5.0

Yes

Yes

No

Str. Thru

Yes

Yes

No

7

36C84-916

24 VAC Natural

3

/

4

x

3

/

4

Fast Open

3.5

2.5

–5.0

No

No

No

Str. Thru

Yes

No

No

8

36C84-921

24 VAC Natural

3

/

4

x

3

/

4

Fast Open

3.5

2.5

–5.0

Yes

Yes

No

Str. Thru

Yes

Yes

No

5

36C84-923

24 VAC Natural

3

/

4

x

3

/

4

Fast Open

3.5

2.5

–5.0

No

No

No

Str. Thru

No

Yes

No

9

36C84-926

24 VAC Natural

3

/

4

x

3

/

4

Fast Open

3.5

2.5

–5.0

No

No

No

Str. Thru

Yes

No

No

4

36C84-936

24 VAC

LP

3

/

4

x

3

/

4

Fast Open

11.0

7.5

–12.0

No

No

No

Str. Thru

Yes

No

No

4

36C87-944

24 VAC Natural

3

/

4

x

3

/

4

Step Open 1.0 1.0

/3.5

2.5

–5.0

No

No

No

Str. Thru

Yes

No

No

6

36C94-906

24 VAC Natural

3

/

4

x

3

/

4

Slow Open

3.5

2.5

–5.0

No

No

No

Str. Thru

Yes

No

No

5

36C94-907

24 VAC Natural

3

/

4

x

3

/

4

Slow Open

3.5

2.5

–5.0

Yes

Yes

No

Str. Thru

Yes

No

No

4

Wiring diagrams – see pages 3-6

Electrical Rating

: 0.6 amps

End to End Dimensions

: 3

15

/

16

Ambient Operating Range

: –40 to +175°F (–40 to 79°C)

Maximum Pressure Rating

:

1

/

2

PSI (14.0

W.C.)

Agency

: A.G.A. and C.G.A. design cer tified

AGA STD. NAT GAS

LP GAS

AGA STD. NAT GAS

LP GAS

Pipe Size

1000 BTU/CU. FT.

2500 BTU/CU. FT.

1000 BTU/CU. FT.

2500 BTU/CU. FT.

1/2 X 3/8

100,000

162,000

15,000-100,000

15,000-162,000

1/2 X 1/2

230,000

372,600

30,000-290,000

30,000-469,000

1/2 X 3/4

230,000

372,600

30,000-290,000

30,000-469,000

3/4 X 3/4

280,000

453,600

50,000-400,000

50,000-648,000

1" Pressure Drop Capacity

Rated Range of Regulation

BTU/HR

BTU/HR

www.white-rodgers.com

Outlet Pressure

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - control and may cause shock or fire hazard.; PRECAUTIONS; CAUTION; WARNING

2 INSTALLATION 1. Turn off electrical power to the system at the fuse box or circuit breaker. Also turn off the main gas supply. 2. If replacing an existing valve, disconnect all plumbing and electrical connections from the old control. 3. The control may be installed in any position except upside d...

Page 3 - PILOT GAS CONNECTION; INSTALLATION; Pilot gas; Figure 3; NOTE; SYSTEM WIRING

3 PILOT GAS CONNECTION Install fitting into pilot gas outlet (see figure 3), turning untilfinger-tight. Insert clean, deburred tubing all the way through thefitting. While holding the tubing securely, slowly tighten fittinguntil you feel a slight "give". Tighten the fitting an additional 1½t...

Page 4 - Figure 5

4 PILOT ADJ. S L COM. BLACK PRESSURE SWITCH TA N TAN REDUNDANT COIL WHITE MAINRELAYCOIL TAN TAN S L COMMON 4 2 3 Figure 5 Cycle pilot plug-in Wiring for 36C84-912, -921 & 36C94-906 Gas Valves 24 VAC LIMIT THERMOSTAT LINE TO ELECTRODE 5059 PILOT RELIGHT CONTROL SILVER PILOT SOLENOID COIL MAIN VAL...