Page 2 - control and may cause shock or fire hazard.; PRECAUTIONS; CAUTION; WARNING

2 INSTALLATION 1. Turn off electrical power to the system at the fuse box or circuit breaker. Also turn off the main gas supply. 2. If replacing an existing valve, disconnect all plumbing and electrical connections from the old control. 3. The control may be installed in any position except upside d...

Page 3 - PILOT GAS CONNECTION; INSTALLATION; Pilot gas; Figure 3; NOTE; SYSTEM WIRING

3 PILOT GAS CONNECTION Install fitting into pilot gas outlet (see figure 3), turning untilfinger-tight. Insert clean, deburred tubing all the way through thefitting. While holding the tubing securely, slowly tighten fittinguntil you feel a slight "give". Tighten the fitting an additional 1½t...

Page 4 - Figure 5

4 PILOT ADJ. S L COM. BLACK PRESSURE SWITCH TA N TAN REDUNDANT COIL WHITE MAINRELAYCOIL TAN TAN S L COMMON 4 2 3 Figure 5 Cycle pilot plug-in Wiring for 36C84-912, -921 & 36C94-906 Gas Valves 24 VAC LIMIT THERMOSTAT LINE TO ELECTRODE 5059 PILOT RELIGHT CONTROL SILVER PILOT SOLENOID COIL MAIN VAL...