White Rodgers 1F83-71 - Manual

White Rodgers 1F83-71

White Rodgers 1F83-71 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; INSTALLING THE THERMOSTAT; INSTALLATION; Figure 1. Back of thermostat base; Figure 2. Thermostat base; NOTE; CHECK THERMOSTAT OPERATION; Fan Operation
  • Page 3 – Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems
  • Page 4 – LOCKOUT BYPASS OPTION; simply press
  • Page 5 – OPERATION; THE THERMOSTAT BASE; The Thermostat Buttons and Switches; HT is displayed when the SYSTEM button has been pressed; OPERATING FEATURES; C CONVERTIBILITY — Press; TROUBLESHOOTING
Loading the manual

Printed in U.S.A.

DESCRIPTION

1F83-71

Non-Programmable Electronic

Digital Automatic Changeover Multi-stage Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

PART NO. 37-6126B

Replaces 37-6126A

0004

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.

PRECAUTIONS

SPECIFICATIONS

CAUTION

!

WARNING

!

WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398

WHITE-RODGERS

Your new White-Rodgers Digital Multi-stage Thermostat uses
the technology of a solid-state microcomputer to provide precise
time/temperature control.

Features:

• Simultaneous heat and cool setpoint storage
• Optional C terminal (dual power option)
• Optional B and O terminals
• Preprogrammed temperature control

• LCD continuously displays setpoint and room temperature

°

F/

°

C convertibility

• Temperature range 45

°

to 90

°

F

• Two-stage heat/two-stage cool
• Armchair programming capability

This thermostat is intended for use with a 24-volt system; do not
use this thermostat with a millivolt or line voltage system. If in
doubt about whether your wiring is millivolt, line, or low voltage,
have it inspected by a qualified heating and air conditioning
contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and
ordinances.

This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.

To prevent electrical shock and/or equipment damage
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.

Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.

Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.

ELECTRICAL DATA
Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)

THERMAL DATA
Setpoint Temperature Range:

45

°

F to 90

°

F (7

°

C to 32

°

C)

Operating Ambient Temperature Range:

32

°

F to 105

°

F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40

°

F to 150

°

F

APPLICATIONS

For use with:

• Heat/cool systems with up to two stages heat, two

stages cool

DO NOT USE WITH:

• Millivolt systems
• Systems exceeding 30 VAC and 2.5 amps
• 3-wire zoned hydronic heating systems

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - REMOVE OLD THERMOSTAT; labels enclosed with the new thermostat.; INSTALLING THE THERMOSTAT; INSTALLATION; Figure 1. Back of thermostat base; Figure 2. Thermostat base; NOTE; CHECK THERMOSTAT OPERATION; Fan Operation

2 REMOVE OLD THERMOSTAT 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the oldthermostat has a wall mounting pla...

Page 3 - Relay contacts shown are thermostatically operated.; Figure 3. Typical wiring diagram for single transformer systems

3 NOTE NOTE The following wiring diagrams show typical terminal identifica-tion and wiring. For proper installation, refer to the originalmanufacturer’s instructions. Relay contacts shown are thermostatically operated. C* R Y2 O B Energized in HEAT Compressor Contactor Stage 1 Heat Relay Stage 1 Hea...

Page 4 - LOCKOUT BYPASS OPTION; simply press

4 Heating System 1. Press SYSTEM button to turn thermostat to HEAT. 2. Press to adjust thermostat setting to 90 ° and hold for five seconds. After you release the button, both stages of theheating system should begin to operate within five seconds. 3. Press to adjust temperature setting below room t...

Other White Rodgers Models

All White Rodgers Other