WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS RD., ST. LOUIS, MO. 63123
(314) 577-1300,

FAX (314) 577-1517

9999 HWY. 48, MARKHAM, ONT. L3P 3J3
(905) 475-4653, FAX (905) 475-4625

Printed in U.S.A.

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.

Type 1131 controls are designed for use on hot water
heating installations. They have single-pole, double-throw
switch action, offering open-on-rise terminals as well as
close-on-rise terminals. These controls may be used as a
high limit, low limit, circulator, or combination low limit-
circulator control.

Models are available with either horizontal or vertical well,
and with either fixed or adjustable differential. Some of
these models also have excess capillary stored within the
enclosure, permitting them to be used with wells having
either a standard or extended shank.

Another model, ideal for replacement purposes, has both
a slotted case and excess capillary stored within the
enclosure. This control can be used with either a standard
or extended shank well, on either horizontal or vertical
well installations.

DESCRIPTION

TYPE 1131

HOT WATER CONTROL

S.P.D.T. Well-Immersion

INSTALLATION INSTRUCTIONS

CAUTION

WARNING

T H I S C O N T R O L M U S T B E I N S T A L L E D B Y A
Q U A L I F I E D I N S T A L L E R .

Do not exceed the specification ratings.

All wiring must conform to local and national electrical
codes and ordinances.

This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.

This control has been accurately calibrated at the factory.
Any attempt to calibrate this control will void the White-
Rodgers warranty.

PRECAUTIONS

CONVERTIBLE CONTROLS

Convertible controls have a Knockout Plate on back of
case (secured by Hex Nut on Horizontal models, and by
Knockout Plug on Vertical models). To convert from
Horizontal to Vertical:

1. Remove control cover. Then remove bottom knockout.

2. Remove Hex Nut (inside control) from Well Mounting

Stem. (To loosen, hold Hex Nut inside while turning
Hex Nut on back of control counterclockwise.)

3. Pull Well Mounting Stem away from case and remove

Knockout Plate.

4. Swing capillary down through slot into bottom knock-

out.

5. Secure Knockout Plate to back of case by using

Knockout Plug provided in envelope.

6. Insert Well Mounting Stem into bottom knockout and

tighten Hex Nut (inside control) securely.

WHITE-RODGERS

Operator: Save these instructions for future use!

PART NO. 37-2071B

Replaces 37-2071 & 37-9195

9548

Do not use on circuits exceeding specified
voltages. Higher voltages will damage control
and could cause shock or fire hazard.

To prevent electrical shock and/or equipment
damage, disconnect electric power to system, at
main fuse or circuit breaker box, until installation
is complete.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WIRING; CAUTION; INSTALLATION

2 CONVERTIBLE CONTROLS CONT. To convert from Vertical to Horizontal model, removeKnockout Plug and Plate. Remove Hex Nut (inside con-trol) and swing capillary upward into back knockout. PlaceKnockout Plate beneath Hex Nut on back of control andtighten Hex Nut (inside control). If bottom knockout is ...

Page 3 - Diagram For Gas Or Oil Fired System With Tankless Domestic Coil; Controls With Adjustable Differential; SETTING THE CONTROL

3 Diagram For Gas Or Oil Fired System With Tankless Domestic Coil X X 24 VAC GAS VALVE HIGH LIMIT TRANS. The R-B contacts of the low limit-circulator control main-tain domestic hot water at the desired temperature year-round. When the thermostat calls for heat the burner starts. Thecirculator also s...

Page 4 - RÉGULATEUR D’EAU CHAUDE; INSTRUCTIONS D’INSTALLATION; DESCRIPTION

ATTENTION Afin de prévenir les chocs électriques et lesdommages matériels pendant l’installation,coupez l’alimentation électrique au panneau dedistribution principal. AVERTISSEMENT N’installez pas cet appareil sur des circuits quidépassent la tension nominale. Une tension tropélevée peut endommager ...