Whirlpool WMH32519HZ - Manual
A user manual for a microwave hood combination outlines essential installation requirements, including electrical safety standards such as grounding and outlet specifications. The guide emphasizes proper ventilation design–covering roof or wall vent configurations, material compatibility, clearance distances, and component sizing–to ensure safe airflow and compliance with building codes. It also addresses system performance by detailing recommended vent lengths and equivalent measurements for ductwork components like elbows and transition pieces.
Table of Contents:
- Page 1 – Microwave Hood Installation Requirements and Safety
- Page 2 – Venting Design Specifications and Transition Pieces
- Page 3 – Vent System Sizing Calculations and Component Lengths
MICROWAVE HOOD COMBINATION
INSTALLATION INSTRUCTIONS
PRODUCT MODEL NUMBERS
WMH32519H
Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W11084412A
05/31/2017
Page 1 of 3
Installation Dimensions
NOTE:
The grounded 3 prong outlet must be inside the upper cabinet.
See the “Electrical Requirements” section.
12" (30.5 cm) min.
14" (35.6 cm) max.
30"
(76.2 cm)
min.
A B
upper cabinet and
side cabinet depth
30"
(76.2 cm)
typical*
66" (167.6 cm) min.
A. 2" x 4" (5.08 x 10.16) wall stud
B. Grounded 3 prong outlet
*30" (76.2 cm) is typical for 66” (167.6 cm) installation height. Exact
dimensions may vary depending on type of range/
cooktop below.
PRODUCT DIMENSIONS
29
⁷⁄₈
" (76.0 cm)
17
¹⁄₈
"
(43.5 cm)
+/-
³⁄₁₆
"
(0.5 cm)
16
¹⁄₄
"
(41.3 cm)
Up to
16
³⁄₄
"
(42.5 cm)*
*Overall depth of product will vary slightly depending on
door design.
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Observe all governing codes and ordinances.
Required:
■
A 120-volt, 60 Hz, AC-only, 15- or 20-amp electrical supply with a fuse
or circuit breaker
Recommended:
■
A time-delay fuse or time-delay circuit breaker
■
A separate circuit serving only this microwave oven
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Whirlpool
- Model
- WMH32519HZ
- Document type
- Manual
- Category
- Microwave
- Language(s)
- English
- Pages
- 3
- File size
- 115.3 KB
- Format
Other Manuals for Whirlpool WMH32519HZ
Summary
Installation instructions detailing electrical requirements, product dimensions, and warnings regarding electrical shock hazards and grounded outlet specifications.
Design specifications for microwave hood venting, including recommended materials, clearance requirements, standard fitting dimensions for roof and wall configurations, and transition piece guidelines.
Guidelines and calculations for determining vent system lengths, equivalent lengths for elbows and caps, and sizing procedures for both rectangular and round vent systems.