Page 3 - click
Page 9 - Contents; translation of the original operating instructions; MAnY tHAnkS fOr PlACinG YOur truSt in uS; we are sure that you will enjoy working with it greatly.
GB 20 Flexio 585 I-Spray Contents 1. Explanation of symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212. General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 10 - Safety at the workplace; Disorder or unlit workplaces may result in
GB 21 Flexio 585 I-Spray 26. Important Note regarding Product Liability! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372 years guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38CE Decl...
Page 11 - electrical Safety; keep the equipment away from rain and moisture.; Safety of Persons; Wear personal safety equipment and always wear safety goggles
GB 22 Flexio 585 I-Spray 2. electrical Safety the tool plug must fit into the socket. the plug may not be modified in any a) form. Do not use adaptor plugs together with protective-earthed tools. Unmodified plugs and suitable sockets reduce the risk of an electric shock. Avoid physical contact with ...
Page 12 - hair, clothes and gloves away from moving parts.; usage and treatment of the electric tool; Do not use power tools whose switch is defective.
GB 23 Flexio 585 I-Spray unexpected situations. Wear suitable clothing. Do not wear wide clothing or jewellery. keep your f ) hair, clothes and gloves away from moving parts. Loose clothing, jewellery or long hair can be caught in moving parts. this device can be used by children over the age of 8 a...
Page 13 - Safety instructions for Spray Guns
GB 24 Flexio 585 I-Spray if the supply cord is damaged, it must be replaced by the manufacturer or it’s b) service agent or a similarly qualified person in order to avoid a safety hazard. 3. Safety instructions for Spray Guns Caution! • Wear breathing equipment: Paint mist and solvent vapors are dam...
Page 14 - field of application; Coating Materials
GB 25 Flexio 585 I-Spray The units may only be used with a functional valve. • if paints rises in the ventilating hose (fig. 1, item 14) do not operate the unit further! Dismantle and clean the ventilating hose, valve and diaphragm and replace the diaphragm if necessary. Do not lay the spray gun. • ...
Page 15 - Sockets and plugs must be masked. risk of an electric shock as a
GB 26 Flexio 585 I-Spray Interior wall paint (dispersions and latex paint) All coating materials with the green Perfect Spray logo WallPerfect (white) 6. Coating Materials Suitable for use Interior wall paint (dispersions and latex paint) Water- and solvent-based paints, finishes, primers, 2-compone...
Page 16 - Preparation of the Coating Material
GB 27 Flexio 585 I-Spray 9. Preparation of the Coating Material Mix the material well in the original container. When using interior wall paint, an • agitator is recommended. i Flexio 585 has been developed for use with all conventional paints in their undiluted form. If the surface is smooth and th...
Page 19 - Clean the housing only with a moistened cloth.
GB 30 Flexio 585 I-Spray i "Cross spray" when using paint with a poor covering capacity or if the surface is highly absorbent (Fig. 11). Interior wall paint in strong colour shades should be applied at least twice (allow first • paint coat to dry first). This will ensure good coverage. 16. i...
Page 20 - spray attachment; Assembly; with the pin facing upwards
GB 31 Flexio 585 I-Spray 18. Cleaning the WallPerfect i-Spray spray attachment Screw of the container and empty it. Pull out the suction tub with container seal. 1) CAutiOn! Never clean seals, diaphragm and nozzle or air holes of the spray gun with metal objects. The ventilation hose and diaphragm a...
Page 23 - Stirring rod; offers the right tool for each work.; Accessories (not included in the delivery); name; For easier coating of ceilings and horizontal objects.
GB 34 Flexio 585 I-Spray Spare Parts list flexio 585 (fig. 25) Pos. Benennung Best. nr. 1 Air filter cover (right + left) 2335 172 2 Air filter set (2 pcs.) 2333 123 3 Stirring rod 2304 419 4 Feed hopper (3 pcs.) 2304 028 Lubricating grease (no fig.) 2315 539 22. Accessories the new CliCk&PAint ...
Page 24 - Correction of Malfunctions; Problem
GB 35 Flexio 585 I-Spray 23. Correction of Malfunctions Problem Cause remedy No coating material emerges from the nozzle Nozzle clogged • Feed tube clogged • Material volume setting turned • too far to the left (-) Feed tube loose • No pressure build-up in container • Ventilating bore (Fig. 12, 1) •...
Page 26 - defect in the product.
GB 37 Flexio 585 I-Spray necessary to specify safety measures to protect the operating personnel. These measures are based on an estimated shutdown during the actual conditions of use (all parts of the operating cycle are taken into consideration here, for example periods when the electric tool is s...
Page 27 - years guarantee
GB 38 Flexio 585 I-Spray Warning If the supply cord of this appliance is damaged, it must only be replaced by a repair shop appointed by the manufacturer, because special purpose tools are required. Warning: Do not connect the blue or brown wire to the earth terminal of the plug! The wires in this m...