Vermont Casting SDDVRBS - Manual

Vermont Casting SDDVRBS

Vermont Casting SDDVRBS – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – Stardance Direct Vent - Rear Vent Gas Heaters; may result in a possible fire hazard and will void the warranty.; Table of Contents
  • Page 3 – Completion of sale, nor for purpose of resale,; Installation & Operating Instructions; Proposition 65 Warning:; Fuels used in gas, woodburning or; Stardance Direct Vent / Rear Vent
  • Page 4 – “GAS VENT DIRECTLY BELOW, KEEP; MANUFACTURER REQUIREMENTS; Gas Equipment Venting System NOT Provided
  • Page 5 – SDDVR; SDDVR Models; Stove Dimensions - Stardance Direct Vent Gas Heater; Stardance dimensions.
  • Page 6 – Installation Requirements; Locating the Stove; We do not recommend the use of wallpaper; Possible stove locations.; Clearance Requirements; Minimum Clearances to Combustible Materials
  • Page 7 – Parallel installation, minimum back and side clearance.; stardance; Corner installation, minimum corner clearance and flue; SDVR; Width; Pinnacle
  • Page 8 – Gas Specifications; Input Input; Gas Inlet and Manifold Pressures; Air Shutter Setting; High Elevations
  • Page 9 – Vertical Termination; NOTE: The restrictor plate supplied with; A vertically terminated vent system must; Some installations may require some adjust-; Restrictor Plate Adjustment; Install restrictor plate as shown in Figure 9 with; Examples for Extended Run/Restrictor Plate Settings; completely down; Vertical vent termination window.
  • Page 10 – Important: All vent clearances must be maintained.; Obstructions or impediments to venting.; IMPORTANT; Vent Termination Clearances; Location of Vent Termination
  • Page 11 – Canadian Installations; General Venting Information - Termination Location
  • Page 12 – Termination clearances.; Termination Clearances; of Caps
  • Page 13 – Vent Components
  • Page 14 – The upper flange of the fan skirt should be located; Installation; Correct position of fan skirt installation.; Stardance RV; Snapstat assembly and installation.; Unpack the Stove
  • Page 15 – rear vent kit; Rear Vent Kit 7TFSRSK installation.; Vent Opening; Locate vent opening.; Vent Opening - Combustible Wall; Venting System Assembly; For Canadian installations:; Rear Vent; Apply sealant to the starter pipe, and fasten to stove; JUV; Attach rheostat to bracket.
  • Page 16 – wall thimble; Minimum wall thimble centerline.; Vent Termination Below Grade; Install inner starter pipe and inner elbow.; Side Wall Termination Assembly
  • Page 17 – Assemble the wall sleeve and firestop.; Determine the vertical pipe length.; install pipe thru wall; Install the horizontal pipe and wall plate parts.; measure thru wall; Measure the horizontal length.
  • Page 18 – Install the vent terminal.; If the; Pinstar; Snorkel kit installation.; snorkel detail; Use extension brackets to mount snorkel against
  • Page 19 – Vent Assembly; vent thru ceiling; Install firestops and attic insulation shield.; vent thru roof; Roof support and flashing.; Vertical Through Existing Chimney
  • Page 20 – blue line; Fireplace; Fireplace Vent System; Fireplace vent system installation.
  • Page 21 – Minimum lintel height for flush or forward placement.; Fireplace Installation Requirements; less completely covered by field fabricated sheet metal. If; Fireplace Installations Using Existing Wood Stove Chimneys
  • Page 22 – Selkirk Direct-Temp Metalbestos Direct; Installation Instructions; Determine whether the length of pipe fits the appli-; Framing Dimension Table 1; Use of Sealant; Inlet End
  • Page 24 – Supporting DIRECT-TEMP: Horizontal Support; Horizontal Installation; Below grade installation.; As a general rule, the wall thimble is optional in; When installed in Canada, a; The wall thimble accommodates wall thickness-
  • Page 25 – Horizontal Termination; Vinyl siding standoff and horizontal termination.; If a vertical rise is necessary on the exterior side; do not back fill; Vertical Installation; Frame openings to the dimensions specified
  • Page 26 – Typical vertical venting configuration.; If the cathedral ceiling support box assembly is; Minimum; Fig. 47 Minimum Height Above Roof Requirements; Whenever DIRECT-TEMP penetrates through a
  • Page 27 – Connect the Gas Supply Line; attach switch assy; Attach switch assembly to rear shroud.
  • Page 28 – Thermostat; Thermostat Connection; Use only a thermostat rated for 500 - 750 millivolts.; Install the wall thermostat in the desired location and; Install the Front Plate; attach switch; Attach switch wires to valve.; Stardance; Install Stove Front.
  • Page 29 – Do not use; Install the Log Set
  • Page 31 – Operation; Pilot and Burner Inspection; RADVT valve control.; SDDVT; Pilot assembly location.; Flame & Temperature Adjustment; Flame adjustment knob for SIT valve.; Your First Fire
  • Page 32 – Flame Characteristics; Pilot flame; Correct pilot and burner flame patterns.; SDDVT Series
  • Page 33 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions; Euro SIT; Lighting instructions
  • Page 34 – Troubleshooting the Gas Control System (SDDVT Series); NOTE; SIT NOVA 820 MILLIVOLT VALVE
  • Page 35 – comfort valve; Honeywell; Comfort control valve.
  • Page 36 – If an Error Code 3 is observed while performing the; Valve
  • Page 37 – Local Path
  • Page 38 – Auto Path; If the setting is; above; If the settings is; below
  • Page 39 – attach gas line; Attach the gas line to the right side of the valve.; Conversion Precautions; LP Configuration; SDDVRC Series Models
  • Page 40 – Gas Conversion; gas conversion; Depress and turn center plunger.; Pilot Orifice Conversion; Pilot Type 1; Rf pilot Conversion; Remove pilot hood. (Your pilot may have a different; RF Pilot conversion; Remove pilot orifice.; Pilot type 2
  • Page 41 – Burner Orifice Conversion; Bottom View; Tilt ember bed slightly to correctly place on venturi; bracket to the edge of the air shutter.; All Models
  • Page 42 – Table 2. Injector Orifice Size Matrix; Conversion to Natural Gas
  • Page 43 – Maintenance; DO NOT; painted surfaces; Remove the Stove Front.
  • Page 44 – Gasket Replacement; Determine the correct length of gasket by laying it; Inspect the Vent System Annually; glass gasket detail; Wrap the gasket material around the outside edge of; Stove Disassembly
  • Page 45 – rdv connections diag.; Schematic Diagram; Wiring Diagrams; On/off switch and optional thermostat circuit.; wiring
  • Page 46 – Stardance Direct Vent/Rear Vent Gas Heater:; Models
  • Page 47 – Stardance Direct Vent/Rear Vent Gas Heater
  • Page 48 – Fuel Conversion Kits; Conversion Kit, NG to LP - SDDVRC Series; Color
  • Page 49 – Optional Accessories; Fan Kits; Specifications; Refer to Page 13 for installation instructions.; Remote Controls; Model Functions Controlled; ON/OFF and Temperature; Screen Kit; Model Color; Midnight Blue
  • Page 51 – PLATED PARTS AND ACCESSORIES:; LIMITED LIFETIME WARRANTY
  • Page 52 – Efficiency Ratings; Model; CFM Corporation
Loading the manual

INSTALLER / CONSUMER

SAFETY INFORMATION

20012950 1/08 Rev. 5

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.

Stardance Direct Vent,

Rear Vent Gas Heater

Models:

SDDVR Series: SDDVRCB, SDDVREB, SDDVRMB,
SDDVRBS, SDDVRCH, SDDVRVG, SDDVRBD
SDDVRC Series: SDDVRCCB, SDDVRCEB,
SDDVRCMB, SDDVRCBS, SDDVRCCH, SDDVRCVG,
SDDVRCBD

Homeowner’s Installation

and Operating Manual

C E R T I F I E D

DESIGN

C ERTIFIE D

Do not store or use gasoline
or other flammable vapors and
liquids in the vicinity of this or
any other appliance.

WHAT TO DO IF YOU SMELL
GAS:

Do not try to light any appliance.

Do not touch any electric switch; do
not use any phone in your building.

Immediately call your gas supplier
from your neighbor’s phone. Follow
the gas supplier’s instructions.

If you cannot reach your gas supplier,
call the fire department.

Installation and service must be
performed by a qualified installer,
service agency or the gas
supplier.

�����
������������������
����

This appliance may be installed in an
after market permanently located
manufactured (mobile) home where not
prohibited by local codes.

This appliance is only for use with the
type of gas indicated on the rating plate.

This appliance is not convertible for use
with other gases unless a certified kit is
used.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Stardance Direct Vent - Rear Vent Gas Heaters; may result in a possible fire hazard and will void the warranty.; Table of Contents

2 Stardance Direct Vent - Rear Vent Gas Heaters 20012950 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation....

Page 3 - Completion of sale, nor for purpose of resale,; Installation & Operating Instructions; Proposition 65 Warning:; Fuels used in gas, woodburning or; Stardance Direct Vent / Rear Vent

3 Stardance Direct Vent - Rear Vent Gas Heaters 20012950 The Stardance Direct Vent Room Heater, Models. SDDVR Series: SDDVRCB, SDDVREB, SDDVRMB, SDDVRBS, SDDVRCH, SD-DVRVG, SDDVRBD; SDDVRC Series: SDDVRCCB, SDDVRCEB, SDDVRCMB, SDDVRCBS, SDDVRCCH, SDDVRCVG, SDDVR-CBD are vented gas appliances listed ...

Page 4 - “GAS VENT DIRECTLY BELOW, KEEP; MANUFACTURER REQUIREMENTS; Gas Equipment Venting System NOT Provided

4 Stardance Direct Vent - Rear Vent Gas Heaters 20012950 Installation & Operating Instructions Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.For all side wall horizontally vented ga...

Other Vermont Casting Models

All Vermont Casting Other