Vermont Casting SA30SKHRN - Manual
Vermont Casting SA30SKHRN – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Gas Pressure Testing:
- Page 3 – Fireplace Specifications; Your Fireplace Must Include:
- Page 4 – Pre-Installation Checklist; All dimensions are minimums.
- Page 5 – Some of the early fireplace units may not; Gas Plumbed on Left Hand Side of Fireplace; Damper locking bracket; Figure 1; Figure 2
- Page 6 – Light a; Damper Stop Installation:; Figure 3; Damper clamp; Figure 4
- Page 7 – ASHK; Figure 5; grate clip; Figure 6
- Page 8 – Leak Test Procedures; Remote Installation; AGa pilot wiring; Figure 8
- Page 9 – Place the larger bottom logs onto the grate,; Be sure; Open the bag of lava rock and spread the rocks; Available Log Sets; 8” Standard Round Log Set; 0” Standard Round Log Set; Grate Enhance kit; Figure 9
- Page 10 – combo log set
- Page 11 – Lighting the Pilot; What To Do If You Smell Gas; For Your Safety Read Before Lighting
- Page 12 – Troubleshooting; Make sure the damper is wide open at all times.; Match Lighting
- Page 13 – Make sure your gas pressure meets the specifications outlined on
- Page 14 – parts; b. Bag of Vermiculite
- Page 15 – Log Set Replacement Parts; Log Sets
- Page 16 – Log parts
- Page 19 – (exclusive of CFM Corporation supplied; B. Cement or ceramic fiber log components:; LIMITED 2/20 YEAR WARRANTY; For VERMONT CASTINGS Decorative Gas Appliances
- Page 20 – CFM Corporation
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
CFM Corporation
Decorative
G
as
A
ppliance
F
or
I
nstallation
I
n
S
olid
F
uel
B
urning
F
ireplaces
3311857 12/05 Rev. 5
Carbon Monoxide Poisoning May Lead To Death
When used without fresh air, gas logs may give off carbon monoxide, an odorless, poisonous gas. Some
people such as pregnant women, people with heart or lung disease, and persons at high altitudes are
more affected by carbon monoxide than others.
Early signs of carbon monoxide poisoning resemble the flu: Headache, dizziness, and/or nausea. If
you have these signs, the gas logs may not be installed or working properly. Get fresh air at once!
Have the gas log set and chimney serviced before using it again.
Certified to ANSI Z21.60
and CGA 2.26 Standards
C E R T I F I E D
DESIGN
C ERTIFIE D
WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
Installation and Operating
Instructions for Vented Gas Log
Sets - Remote Hearth Kits
Models:
SA18SHKRN, SA18SHKRP,
SA24SKHRN, SA24SHKRP,
SA30SKHRN, SA30SKHRP
ATTENTION
Installation, service, and repair of this ap-
pliance must be performed by a qualified
installer, service agency, company or gas
supplier experienced with this type of gas
appliance.
INSTALLER:
Read these instructions completely and care-
fully prior to beginning installation. After instal-
lation, leave these instructions with the owner.
OWNER:
Read these instructions and follow the warn-
ings. Save this manual for future reference.
Check local codes before installing this log set.
In some areas of the country, gas log sets are
restricted.
The installation and the provisions for combus-
tion and ventilation air must conform with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
—
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
—
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not
use any phone in your building.
•
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppli-
er’s instructions.
•
If you cannot reach your gas supplier, call
the fire department.
Please record your gas log’s model number for
future reference here:
Note: This model # can be found on the box or
the label attached to the back of the burner pan.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 3311857 WARNING Do not use this appliance or any part that has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. WARNING Young children are not allowed to operate t...
3 3311857 Before You Begin -- Attention! A. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and...
4 3311857 CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please contact your dealer/distributor for assistance. Is the gas supply inlet pressure correct? NG: Min. 5.5” w.c./Max. 14.0” w.c. LP: Min. 11” w.c./Max. 14.0” w.c. Does the firebox meet the minim...