Vermont Casting LHER20 - Manual

Vermont Casting LHER20

Vermont Casting LHER20 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – LHE Series Natural Vent Insert; Table of Contents
  • Page 3 – can not be installed directly onto or into combustibles.; Installation & Operating Instructions; PLEASE READ THE FOLLOWING CAREFULLY; Please ensure that your room is well ventilated - open; Locating Your Gas Fireplace Insert; Proposition 65 Warning:; Insert Applications
  • Page 4 – Fireplace & Trim Dimensions; Minimum Fireplace; LHESLGA is only available for; Zero Clearance Kit
  • Page 5 – Mantels; Minimum mantel height above fireplace.; Insulating around the fireplace will result in; Zero Clearance Applications; For installation other than in existing wood-; LHE insert framing dimensions.
  • Page 6 – Natural; Gas Inlet & Manifold Pressures; Always provide a union; High Elevations
  • Page 7 – INSTA VENT FREE; Gas Supply Pressures; WIRING DIAGRAM; Installation of Trim Switch
  • Page 8 – Venting Installation; REMOTE SWITCH WIRING - NVC; SIT Valve; Remote switch; Honeywell Valve; For left side installation, reverse switch position in; WARNING; Left Side Installation; Insert ON/OFF switch with wiring assembly into
  • Page 9 – Common Flue Installations; the installation is complete.; Flue outlet; Remove flue collar plate and attach to flue collar.
  • Page 10 – Ceramic Refractory Installation; LHEDV; Left Side; Ceramic refractory.; Blocked Flue Shut Off System; Access to the blocked flue shut off swtich from inside; Vent safety switch; Blocked flue shut off switch location.
  • Page 11 – Operating Instructions; General Glass Information; The use of substitute glass will void all product; Louvre Removal; Lift up and unhook glass frame at the top.; Log Installation and Burner Lava Rock; e. Place the burner lava rock on the front area of the
  • Page 12 – First Firing; LO; Flame adjustment knob for Honeywell Valve.; Flame Characteristics; f. Place the burner lava rock on the front area of the; LHEC30 and LHER30 log and lava rock placement.; logs; LHEC20 and LHER20 log and lava rock placement.
  • Page 13 – SIT Pilot; Correct pilot flame appearance.; Turn; Flame adjustment knob for SIT Valve.; log flames; Correct burner flame appearance for LHEC20 and LHER20.; Log flames; Correct burner flame appearance for LHEC30 and LHER30.
  • Page 14 – FOR YOUR SAFETY READ BEFORE LIGHTING; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
  • Page 15 – SYMPTOM; Troubleshooting the Gas Control System; SIT NOVA 820 Millivolt Valve
  • Page 16 – Honeywell Millivolt Valve
  • Page 17 – Instructions for RF Comfort Control Valve; Comfort conrol valve.; Transmitter diagram.
  • Page 18 – Fan; Comfort Valve wiring diagram.
  • Page 19 – LED Count; Auto Path
  • Page 20 – Local Path
  • Page 21 – Maintenance; Burner and Burner Compartment; Cleaning the Standing Pilot
  • Page 22 – LHE Series
  • Page 25 – Optional Accessories
  • Page 26 – Modification Instructions of; WARNING: You must turn off gas supply to; remove bottom door rail; Remove the bottom door rail.; remove old burner; Remove the old burner assembly.; remove inner baffle; Remove the decorative burner hood and inner baffle.; insert in; Install insert by pushing it all the way inside the shell.
  • Page 27 – IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
  • Page 28 – Efficiency Ratings; Model; CFM Corporation
Loading the manual

10005360 5/06 Rev. 5

Natural Vent Insert
Models: LHER20

LHEC20

LHER30

LHEC30

DESIGN

C ERTIFIE D

C E R T I F I E D

DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

do not use any phone in your

building.

Immediately call your gas

supplier from your neighbor’s

phone. Follow the gas suppliers

instructions.

If you cannot reach your gas

supplier call the fire department.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE

INSTALLER/CONSUMER

SAFETY INFORMATION

FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.

Homeowner's Installation and

Operating Manual

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - LHE Series Natural Vent Insert; Table of Contents

2 10005360 LHE Series Natural Vent Insert Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert. IMPORTANT - Read all instructions and warnings carefully before star...

Page 3 - can not be installed directly onto or into combustibles.; Installation & Operating Instructions; PLEASE READ THE FOLLOWING CAREFULLY; Please ensure that your room is well ventilated - open; Locating Your Gas Fireplace Insert; Proposition 65 Warning:; Insert Applications

3 10005360 LHE Series Natural Vent Insert This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S. Installations follow local codes and/or the current Natio...

Page 4 - Fireplace & Trim Dimensions; Minimum Fireplace; LHESLGA is only available for; Zero Clearance Kit

4 10005360 LHE Series Natural Vent Insert N O P E M F 5360 LHE ac spces 5/03 U S R Q V T FP1248 Minimum fireplace opening 1/03 Q - Fireplace opening heightR - Fireplace opening widthS - Depth of insertT - Firebox width at insert depth(S) LHEC20 LHER20 LHEC30 LHER30 A-1 20 ⁷⁄₈ " (530 mm) 20 ⁷⁄₈ &...

Other Vermont Casting Models

All Vermont Casting Other