2 10003929 TABLE OF CONTENTS Please read the Installation & Operating Instructions before using this appliance. Thank you and congratulationson your purchase of a Irving Oil fireplace. IMPORTANT - READ ALL INSTRUCTIONS AND WARNINGS CAREFULLY BEFORE STARTING INSTALLATION. FAILURETO FOLLOW THESE I...
Page 3 - MANTELS; Your Direct Vented Insert unit is designed; LOCATING YOUR; INSTALLATION INSTRUCTIONS
3 10003929 When the unit is installed into a woodburning fireplace, theminimum distance the mantel can be placed above thefireplace is governed by local building codes applicable towoodburning fireplaces. Consult local authorities havingjurisdiction for these clearances. The underside of themantel w...
Page 4 - FIREPLACE & TRIM DIMENSIONS; SS or SSD Trim
4 10003929 FIREPLACE & TRIM DIMENSIONS R T Q U S V R - Fireplace opening widthQ - Fireplace opening heightS - Depth of insertT - Firebox width at insert depth(S)U - Firebox depth at insert back height (V)V - Insert back height MINIMUM FIREPLACE INSERT OPENING 1= SS or SSD Trim 2= SL or SLD Trim ...
Page 5 - PREPARATION; Vented Gas Fireplace Heaters; GAS INLET & MANIFOLD PRESSURES; Input Minimum; GAS LINE INSTALLATIONGAS
5 10003929 Do not use this appliance if any part of it hasbeen under water. Immediately call a quali-fied service technician to inspect the unitand replace any part of the control which hasbeen under water. When purging the gas line, the frontglass must be removed. The gas pipeline can be brought in...
Page 6 - Trim; SIT VALVE; PILOT; TP; HONEYWELL VALVE
6 10003929 INSTALLATION OF TRIM SWITCH FOR RP GAS VALVES 1. Thread wire through openings on the right side offireplace. Do not cut wire or insulation on metal edges. 2. Slide switch assembly from the back, betweensubframe and trim, then fasten the screw. (Fig. 3) 3. For left side installation revers...
Page 7 - VENTING DIAGRAM
7 10003929 Under no circumstances shouldinsulation be put between the damper and the top of the unit. This may causecondensation and overheating of the unit. LINER INSTALLATION - Fig. 6 VENTING DIAGRAM Secure with clamp and three screws Flue gas exits through the vent termination rain cap 1) Attach ...
Page 8 - CAUTION: LOGS MAY BE HOT; Once fan starts, adjust speed control to desired fan
8 10003929 FLUE COLLAR PLATE MOVE BACK CABINET TOP FIG .4 FASTENER PLATE MAKE SURE THE FLUE COLLAR PLATE IS IN CONTACT WITH THE BACK EDGE OF THE CABINET TOP PLATE FLUE COLLAR CABINET TOP FIG.5 FASTENER PLATE MACHINE SCREW AFTER FASTENED Fig. 8 Fig. 9 Fig. 10 Fig. 11 FAN KIT Should this fan require s...
Page 9 - OPERATING INSTRUCTIONS; GENERAL GLASS INFORMATION; Only ceramic glass approved by Vermont; The use of substitute glass will void all product; LOUVRE REMOVAL; To remove louvre pull louvre up and then lift out.; GLASS FRAME REMOVAL; Lift up and unhook glass frame at the top.; GLASS CLEANING; Remove logs from packaging.
9 10003929 GLASS FRAME W OPERATING INSTRUCTIONS GENERAL GLASS INFORMATION Only ceramic glass approved by Vermont Castings Majestic Products Company may be used for replacement on this unit. 1. The use of substitute glass will void all product warranties. 2. Care must be taken to avoid breakage of th...
Page 10 - CAUTION: LOGS MAY BE HOT; LARGE LAVA ROCK PLACEMENT
10 10003929 CERAMIC REFRACTORY INSTALLATION 1. Remove front glass. 2. Remove logs from unit. 3. Remove refractory from package Refractory are fragile and must be han-dled with care. Where at all possible, twohands should be used when handling. 4. Take centre refractory and tilt so bottom edge slides...
Page 11 - LO; FLAME ADJUSTMENT; SIT Pilot; SIT Valve
11 10003929 LO HI Turn counterclockwise to decrease flame height. Turn clockwise to increase flame height. Fig. 18 FLAME ADJUSTMENT Flame adjustment is accomplished by rotating the Hi/Loadjustment knob located near the centre of the gascontrol. (Fig. 18) It is important to periodically perform avisu...
Page 12 - FOR YOUR SAFETY READ BEFORE LIGHTING; TO TURN OFF GAS TO FIREPLACE; LIGHTING AND OPERATING INSTRUCTIONS; EURO SIT; LIGHTING INSTRUCTIONS
12 10003929 1. STOP! Read the safety information above on this label. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4.For RN/RP appliances turn the On/Off switch to offposition or set thermostat to lowest level. 4. Open control access panel. 5. ...
Page 13 - TROUBLE SHOOTING THE GAS CONTROL SYSTEM; SIT 820 MILLIVOLT VALVE
13 10003929 SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off pilot and electrode at pilot. push the red button again. If pilot will not light - check gapat electrode and pilot-should be 1/8"...
Page 14 - START; CHECK; HONEYWELL MILLIVOLT VALVE
14 10003929 • GAS SUPPLY ON • SUPPLY LINE HOOKED UP• SHUTOFF VALVE OPEN NO NO NO NO • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.• FOR SPARK AT ELECTRODE WHILE DEPRESSING PIEZO — 1/8" GAP TO PILOT HOOD NEEDED.• ALL WIRING CONNECTIONS• REPLACE PIEZO IGNITOR • FOR AIR IN THE LINES• THERMOP...
Page 15 - REPLACEMENT PARTS
15 10003929 REPLACEMENT PARTS IRHEDV32 35 30 31 32 27 29 28 25 26 3 2 33 34 22 24 15 LO H I PILOT ADJ PILOT ON OFF 23 a/b 21 20 19 14 12 16 8 a/b 9 a/b 13 18 17 11 a/b 18 10a/b
Page 16 - REPLACEMENT PARTS LIST; Description
16 10003929 REPLACEMENT PARTS LIST Description IRHEDV32 1 Log Set Complete 57896 1a Log Ember Front KR1 1b Log Front Left KR2 1c Log Front Right KR3 1d Log Rear KR4 1e Log Top Left KR5 1f Log Top Right KR6 2 Lava Rock (Package) 10001454 3 Burner Lava Rock (Package) 57897 4a Burner Complete With Tile...
Page 17 - A-TRIM OPTIONS FOR RHEDV32; FRAME ASSEMBLY; screws to assemble each piece.
10003929 A-TRIM OPTIONS FOR RHEDV32 17 FRAME ASSEMBLY 1. Lay Trim Top Facing and Trim Side Facings, face downon to an even surface such as a table or floor. Be surenot to scratch the painted surfaces. 2. Install the nuts and bolts (Fig. 21). Fig. 21 A1) RHESS, RHESL, RHESSD, RHESLD & RHESXL TRIM...
Page 18 - AS SHOWN FROM FRONT; FRAME MOUNTING; GENERAL INFORMATION
10003929 Fit Decorative Frame to the fireplace and fasten (Fig. 25). Plastic on the trim must be removedbefore mounting onto the fireplace. Glass must be tightly pressed against thefront of the frame in order to preventscrews from damaging glass edges. Fig. 25 AS SHOWN FROM FRONT SCREWS FRAME MOUNTI...
Page 19 - TRIM REPLACEMENT PARTS LIST; Specify Finish (Antique or Polished Brass); SS and SSD trim dimensions are for openings smaller than 26
10003929 KEY DESCRIPTION RHESS (2) RHESL (3) RHESSD (3) RHESLD (3) RHESXL (4) 1 Trim Frame Top, Flat Black 57929 57932 57929 57932 57935 2 Trim Frame Left, Flat Black 57927 57930 57927 57930 57933 3 Trim Frame Right, Flat Black 57928 57931 57928 57931 57934 4 Trim Top Deflector (1) 17634 17634 17634...
Page 20 - TRIM ASSEMBLY; RHEBSL
10003929 TRIM ASSEMBLY 1. Install trim channels (left and right sides). Use twoscrews to assemble each piece. 2. Slide on the trim top channel and fasten it from theback side. 3. Install the trim top deflector and use two screws tofasten it. (Fig. 26) 4. Remove ALL plastic protective covering from b...
Page 21 - A3) RHEFA and RHEFP TRIMS; Glass; Install bottom decorative plate by simply sliding it; ALL repair parts will be available from your local dealer.
10003929 A3) RHEFA and RHEFP TRIMS Glass Frame Louvre Note:Position brass trim top as shown (small end up) to prevent heat discolouration Fig. 27 Fig. 28 1. Remove the front glass (see "Glass Frame Re- moval" section). 2. Install support window trim channel, top and bottom brass trim by usin...
Page 22 - DO NOT REMOVE EXISTING GLASS WITH FRAME; HECBTKP, HECBTKMB and HESBTKP Trim Assembly
10003929 A4) HEBTKP, HESBTKP, HECBTK, HECBTKMB & HEBTA TRIMS HECBTK - Cast bay window and grills in classic black trim kit HECBKMB - Cast bay window and grills in midnight black porcelain enamel trim kit HESBTKP - Steel bay window with polished brass and cast grills in classic black trim kit HEB...
Page 23 - HEBTKP Trim Assembly
10003929 1) Reposition controls. a) Remove the Fan Speed Control Box (Fig. 33).b) Attach the Fan Speed Control Box to the Bracket (Fig. 34) and install the Bracket into the Cabinet. Only for RN/RP VALVE units.c) Install the Control Knobs Extensions onto the appropriate Control Valve Knobs (Fig. 34)....
Page 26 - Riser Trim Dimensions; A5) CAST TRIM OPTIONS; Cast Surround And Flat Face; A6) FREESTANDING KITS; Convert Insert Into a Freestanding Stove
10003929 26 1. Install the unit according to Homeowner’s Manual. 2. Install the trim according to Installation Instructions. 3. Remove the two (2) screws at the bottom of the trim. 4. Install the riser at the bottom of the trim (Fig. 58). 5. Fasten the trim with the same two (2) screws removedon ste...
Page 27 - Note: Air Intake has a Blue Line on the vent.; Note: Air Intake has a Blue Line on the vent.; D - High Temperature Sealant; FLEX VENT 25 FT. LENGTH; VENTING COMPONENTS
10003929 8" x 12" VENT TERMINATION KIT Model: HEDVT (8" x 12") (Fit Typical 8" x 12" and 9" x 13" flue Tile) Kit Includes: A - 8" x 12" Vent Termination (x1) B - Stainless Steel Clamps 3"-3.5" (x4) C - Hardware Package (x1) D - High Temperature Sealant...