Vermont Casting DVRT41 - Manual

Vermont Casting DVRT41

Vermont Casting DVRT41 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 2 – DVRT41 Direct Vent Gas Fireplace; General Venting; Table of Contents
  • Page 3 – DVRT41Direct Vent Gas Fireplace; Installation & Operating Instructions; Locating Your Fireplace; PLEASE READ THE FOLLOWING CAREFULLY; Fig. 1 Locating Gas Fireplace
  • Page 4 – Framing Dimensions; Fireplace Dimensions (Installed as Top Vent); Fig. 2 Fireplace specifications and framing dimensions.
  • Page 5 – Fireplace Dimensions (Installed as Rear Vent); Fig. 3 Fireplace specifications and framing dimensions.
  • Page 6 – Mantels; Fig. 4b Combustible mantel leg minimum installation.; Hearth; Fig. 4a Combustible mantel minimum installation.; Mantel Chart
  • Page 7 – Certified To; Vented Gas Fireplace Heater; Flange Location for; Flange
  • Page 8 – Remote ON/OFF Switch Installation; Thread wire through the electrical knockout located; Alternate Switch Location; Fig. 7 Remote switch wiring diagram for R models.
  • Page 9 – Optional Top Vent Application; Rear View; NOTE: Be sure not to damage any gasket material.
  • Page 10 – If vent terminal is installed in an accessible location,; Location of Vent Termination; Fig. 12 Replacing flue cover and flue pipe.
  • Page 11 – Canadian Installations; General Venting Information - Termination Location
  • Page 12 – Termination Clearances; General Information Assembling Vent Pipes; Flex Vent Pipes; Fig. 16 Apply high temperature sealant to 4” and 7” pipes.
  • Page 13 – Twist Lock Pipes; EXAMPLE; Refer to Page 19 for venting; Vertical dimension from the floor of the unit; Horizontal dimension from the outside face of the wall to the; Rear Wall Vent Application
  • Page 14 – Rear Wall Vent Installation; Combustible Walls: Cut a 10; elbow is being used attach the; Opening for Noncombustible Wall
  • Page 15 – Fig. 23 Side view of final unit location.; Vertical Sidewall Application; Transition Elbow; Rear Wall Vent Installations -; Follow Steps 1 and 2 on Page 14.; angle. Do not exceed 45
  • Page 16 – Total angular variation =; elbows per installation.; Fig. 27 Maximum horizontal run with no rise.
  • Page 17 – Vertical Sidewall Installation; Combustible Walls: Cut a 9; Fig. 32 Adjustable zero clearance sleeve.
  • Page 18 – off; Fig. 36 Bend flex vent at 90; so horizontal portion is 6
  • Page 19 – Below Grade Installation; Do not back fill around snorkel.
  • Page 20 – Attic Insulation Shield
  • Page 22 – Venting Components
  • Page 23 – Operating Instructions
  • Page 24 – Installation of Logs; Fig. 49 Flame adjustment knob for Honeywell valve.; Honeywell Valve; LOGS; Log Identification Chart
  • Page 25 – Flame Characteristics; Fig. 50 Flame adjustment knob for SIT valve.; Inspecting the Venting System; SIT Pilot; Fig. 52 Correct burner flame appearance for DVRT41.
  • Page 26 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
  • Page 27 – Lighting & Operating Instructions; Do not try to light any appliance.; For Your Safety, Read the Following Warnings; Valve in the “ON” position
  • Page 28 – Instructions for RF Comfort Control Valve
  • Page 29 – Fan
  • Page 30 – LED Count; Auto Path
  • Page 31 – Local Path
  • Page 32 – Window Frame Assembly to be Removed Before Service Work; Troubleshooting – Honeywell VS8421
  • Page 33 – SYMPTOM
  • Page 34 – SIT 822 Valve with a Honeywell Electronic Igniter; START
  • Page 35 – Fuel Conversion Instructions; Conversions must be completed by qualified personnel; Burner and Pilot Orifice Conversion
  • Page 36 – Front View; Installation Precautions
  • Page 37 – Fig. 65 Depressd and turn center plunger.; NOTE: It is not necessary to remove the pilot tube for
  • Page 38 – Burner and Burner Compartment; Cleaning the Standing; Maintenance
  • Page 40 – Description
  • Page 42 – LP to Natural Gas
  • Page 43 – Optional Accessories Available; FK12 Fan Assembly; Method A; Fan Kits; Side View
  • Page 44 – Remote Controls; IMT; Wall mounted thermostat control; Ceramic Refractory Panels; Unit; Decorative Bay Windows; The bay window kit is available for the DV360 only.; Installation; Remove the existing louvre assembly top.; Section A; Decorative Frame Trim
  • Page 45 – For Use in Mobile Homes: Model DVRT41RMH; Conversion Instructions
  • Page 47 – IF WARRANTY SERVICE IS NEEDED...; ) DO NOT ATTEMPT TO DO ANY SERVICE WORK; LIMITED LIFETIME WARRANTY
  • Page 48 – Efficiency Ratings; Model; CFM Specialty Home Products
Loading the manual

Homeowner's Installation and

Operating Manual

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER

Direct Vent
Model: DVRT41

DO NOT STORE OR USE
GASOLINE OR OTHER FLAM-
MABLE VAPORS AND LIQUIDS
IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL
GAS:

Do not try to light any
appliance.

Do not touch any electric
switch; do not use any phone in
your building.

Immediately call your gas
supplier from your neighbor's
phone. Follow the gas suppliers
instructions.

If you cannot reach your gas
supplier call the fire
department.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE

INSTALLER/CONSUMER

SAFETY INFORMATION

C E R T I F I E D

DESIGN

C E R

T I F I E D

FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.

10006740 1/05 Rev. 2

410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777

www.majesticproducts.com • www.vermontcastings.com

CFM Specialty Home Products

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DVRT41 Direct Vent Gas Fireplace; General Venting; Table of Contents

2 DVRT41 Direct Vent Gas Fireplace 10006740 Installation & Operating Instructions ........................................................................................................... 3 Locating Your Fireplace ...................................................................................

Page 3 - DVRT41Direct Vent Gas Fireplace; Installation & Operating Instructions; Locating Your Fireplace; PLEASE READ THE FOLLOWING CAREFULLY; Fig. 1 Locating Gas Fireplace

3 DVRT41Direct Vent Gas Fireplace 10006740 A) Flat on wall B) Cross corner C) **Island D) *Room divider E) *Flat on wall corner F) Chase installation Y) 6" minimum Note (Fig. 1):** Island (C) and Room Divider (D) installation is possible aslong as the horizontal portion of the vent system (X) do...

Page 4 - Framing Dimensions; Fireplace Dimensions (Installed as Top Vent); Fig. 2 Fireplace specifications and framing dimensions.

4 DVRT41 Direct Vent Gas Fireplace 10006740 Ref. DVRT41 A 41” (1041mm) B 37” (940mm) C 36” (914mm) D 24 ¹⁄₂ ” (622mm) E 7” (178mm) F 6” (152mm) G 1 ¹⁄₄ ” (32mm) H 19 ¹⁄₂ ” (495mm) I 5 ¹⁄₂ ” (140mm) J 25” (635mm) K 5/8” (16mm) L 10 ³⁄₄ ” (273mm) M 2” (51mm) N 7 ⁵⁄₈ ” (194mm) O 1 ⁷⁄₈ ” (48mm) P 7” (17...

Other Vermont Casting Models

All Vermont Casting Other