Vermont Casting 4030 - 4049 - Manual
Vermont Casting 4030 - 4049 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – UVS27 Vent-Free Gas Heater; Table Of Contents; ing or oil fired appliances, and the products of combus-
- Page 3 – Installation & Operating Instructions; Read this owner’s manual carefully and
- Page 4 – Shell Dimensions; UVS27 freestanding shell dimensions.; Freestanding Stove; UVS27 Hearthmount specifications.; Hearthmount; CL; Freestanding specs
- Page 5 – Hearth Requirements; Clearance Requirements; Minimum Clearances to
- Page 6 – Firebox weight / shipping; Unvented Heaters; Inlet Minimum; Gas Inlet and Manifold Pressures; Natural; Gas Specifications; Gas
- Page 7 – ) Unusually Tight Construction; Space; is defined as the room in which you will install; This heater must have fresh air for proper opera-; The following informa-
- Page 8 – Confined; W A R N I N G; Vent options to provide additional air.
- Page 9 – Assembly Procedures; CAUTION; Install cover plate; Attach rheostat to bracket.; Place upper flange behind lower edge of shroud.; pinnacle; Attach snapstat to inner shroud.; snapstat; WARNING
- Page 10 – Glass & Catalyst Installation; Thermostat Wire / Gauge; Optional Thermostat/Remote Wiring; Thermostat; screen removal; Install ON/OFF Switch; Run wires down back of stove, under bottom of rear; attach switch; Attach switch wires to valve; attach switch assy; Attach switch assembly to rear shroud.
- Page 11 – RNVOD; injector orifice; UVS pin
- Page 12 – NEVER test with an open flame.; Install Log Set; Remove the logs from their packaging, and inspect
- Page 13 – UVS27 logs in place.; Complete the Installation; Install the Front Plate. Your Front may look different
- Page 14 – Hearthmount assy; Engage the Hearthmount Front with the notch in the; Install the Top Plate and Grille.
- Page 15 – Operation; Your First Fire; Pilot assembly location.; Flame & Temperature Adjustment; Flame adjustment knob for Honeywell Valve.; LO; Eurosit control; Flame adjustment knob for Eurosit Valve.; Flame Characteristics; Correct pilot flame appearance.; Correct burner flame pattern.
- Page 16 – FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
- Page 17 – Troubleshooting; Honeywell valve assembly.
- Page 18 – Troubleshooting cont’d.; CONDITION; Correct LP Pilot Flame.; JUV; Pilot flame is lifting.
- Page 19 – Maintenance; Remove the screen or glass panel.
- Page 20 – Catalytic Combustor
- Page 21 – UVS27R, UVS27M Vent Free Gas Heaters
- Page 24 – Optional Accessories Available; Fan Kits
- Page 27 – IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
- Page 28 – CFM Corporation
This is an unvented gas-fired heater.
It uses air (Oxygen) from the room
in which it is installed. Provisions for
adequate combustion and
ventilation air must be provided.
Refer to Page 7.
UVS27R, UVS27M
Vent Free Gas Heaters
Models: 4030-4049, 4085-4087,
4090-4092
20007068 4/07 Rev. 8
INSTALLER / CONSUMER
SAFETY INFORMATION
WARNING: If the information in this
manual is not followed exactly, a
fire or explosion may result causing
property damage, personal injury or
loss of life.
Please read this manual before
installing and using appliance.
Homeowner’s Installation
and Operating Manual
DESIGN
C ERTIFIE D
—
Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
—
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do
not use any phone in your building.
•
Immediately call your gas
suppler from a neighbor’s phone. Fol-
low the gas suppler’s instructions.
•
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
7068
PinStar fa
cover
1/04
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an after
market permanently located manufactured
(mobile) home where not prohibited by lo-
cal codes.
This appliance is only for use with the type
of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 UVS27 Vent-Free Gas Heater 20007068 Installation and Operating Instructions Shell Dimensions ................................................................................................................. 4 Clearance Requirements .....................................................................
3 UVS27 Vent-Free Gas Heater 20007068 Installation & Operating Instructions In order to ensure safe and effective installation, this unit must be installed only by a qualified agency, individual, firm, corporation or company that is experienced in the instal-lation, repair and servicing of this ty...
4 UVS27 Vent-Free Gas Heater 20007068 Shell Dimensions Drawing Not to Scale Fig. 1 UVS27 freestanding shell dimensions. Freestanding Stove 7068 CL 5004 UVS Hearthmount specs 1/02 5" (140 mm) 25 ��� " (641 mm) 26 ��� " (673 mm) ����� " (416 mm) 5004 Fig. 2 UVS27 Hearthmount specificati...