Vermont Casting 36CDVTRN - Manual

Vermont Casting 36CDVTRN

Vermont Casting 36CDVTRN – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – CDV Series Direct Vent Gas Fireplace; PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS; Table of Contents; Logs
  • Page 3 – OFF; PLEASE REVIEW THE FOLLOWING CAREFULLY; Locating Your Fireplace; Installation & Operating Instructions; Proposition 65 Warning:
  • Page 4 – Fireplace Dimensions - Rear Vent; Fireplace specifications and framing dimensions.; Framing Dimensions
  • Page 5 – Fireplace Dimensions - Top Vent
  • Page 6 – Hearth; Mantel; Combustible mantel leg minimum installation.; Mantel Chart; Mantel Shelf or; Combustible mantel minimum installation.
  • Page 7 – DO NOT; Final Finishing; Vented Gas Fireplace Heaters; Framing and Finishing; must; Gas Specifications; flange location; Flange Location for Desired; standoff location; Standoff Location for Desired Drywall Depth at Header; Hood Installation; CAUTION: Hood MUST be permanently installed.
  • Page 8 – Installation; INSTA VENT FREE; Typical gas supply installation.; Remote switch; Remote switch wiring diagram.; 20V Electrical Hook Up
  • Page 9 – electric cover plate and secure.; Electric receptacle.; General Venting; There must not be any obstruction
  • Page 10 – General Venting Information - Termination Location; Canadian Installations
  • Page 11 – Termination Clearances; Canadian Installations:; Flex Vent Pipes; Termination clearances.; Apply high temperature sealant to 4” and 7” pipes.
  • Page 12 – How to Use the Vent Graph; Horizontal dimension from the outside face of the; ertical dimension from the fl; DV Graphic; Rear Wall Venting Applications; Twist Lock Pipes; 6CDVR Venting
  • Page 13 – Top View; Rear vent applications.; Rear Wall Installation; Combustible Walls; Cut a 9; Noncombustible Walls; Hole opening must; Vent Opening; Vent Opening for Combustible Wall; Locate vent opening on wall.; Install interior firestop as shown in Figure 14.; Side View Vent Termination; Slide fireplace into position.
  • Page 14 – Rear Wall Vent Installations -; Locate the center of the hole 29; Grasp the vent pipe close to the collar and bend to
  • Page 15 – Secure collar in place, slide termination into collar.; Rear Wall Vent Application; Locate the hole 27; The centerline of the termination must be 27; Vertical Sidewall Applications
  • Page 16 – Maximum vent run with elbows.; Maximum number of elbows.; Vertical Sidewall Installation; Opening for Noncombustible Wall; Maximum horizontal vent run.; •IMPORTANT•; Minimum clearance between vent
  • Page 17 – Measure horizontal length including 2” overlap.; Always start vertical run with 7TCDV90 on 36CDVR; Apply high temperature sealant.
  • Page 18 – Below Grade Installations; Ensure sidewall venting clearances are observed.; Snorkel; Snorkel installation, recessed foundation.; Below grade installation; Below grade installation.; Up to two 45° elbows may be used within the
  • Page 19 – Typical vertical; Typical vertical roof applications.; above and mark position.
  • Page 20 – Minimum termination to roof clearance.; 6CDVT Vertical Venting
  • Page 21 – Support straps for horizontal runs.; According to the chart the maximum
  • Page 22 – Maximum number of elbow degrees.; Noncombustible Walls:; Vertical Sidewall Installations; cal height (X) required from the base of the flue collars; Vertical height requirement.
  • Page 23 – Apply high temperature sealant to collars or termina-; pipe coming through the wall.
  • Page 24 – Top Vent; This Gas Fireplace has been approved for:; through the roof
  • Page 25 – Typical offset application.; Typical ceiling/roof support; Typical Roof Support; Roof and ceiling supports.
  • Page 27 – Vent Components; Venting Components; Elbow; Vent components; Must order a 7TCDV90 elbow
  • Page 28 – the window frame assembly by pulling down on the; Operating Instructions; Glass Information; Louvre removal; Remove top louvre; remove glass frame; Window frame assembly removal.
  • Page 29 – Flame adjustment knob for SIT valve.; bottom; Log Front; 6CDV burner flame appearance.
  • Page 30 – FOR YOUR SAFETY READ BEFORE LIGHTING; Follow the gas supplier’s instructions.; To Turn Off Gas to Fireplace; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
  • Page 31 – For Fireplaces equipped with SIT822 Gas Valve (EN or EP)
  • Page 32 – SYMPTOM; NOTE; SIT NOVA 820 MILLIVOLT VALVE
  • Page 33 – SIT top Convertible Pilot; Fuel Conversion Instructions; Nova SIT820 Gas Valve.
  • Page 34 – Burner and Burner Compartment; Cleaning the Standing; If repair is necessary, it should; Maintenance
  • Page 35 – CDV; b. Log Middle Assy
  • Page 36 – Clamp Frame Window; Fuel Conversion Kits
  • Page 37 – Specifications; Optional Accessories Available; Fan Kits; fan install; FK12 fan placement.; Wiring Instructions; Model
  • Page 39 – IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
  • Page 40 – CFM Corporation; Efficiency Ratings
Loading the manual

Installation Instructions and

Homeowner’s Manual

20010175 6/06 Rev. 2

Builder Direct Vent
Models:

36CDVRRN

(Rear Vent)

36CDVTRN

(Top Vent)

DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch;

do not use any phone in your

building.

Immediately call your gas

supplier from your neighbor’s

phone. Follow the gas suppliers

instructions.

If you cannot reach your gas

supplier call the fire department.

WARNING!

IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE

INSTALLER/CONSUMER

SAFETY INFORMATION

FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.

DESIGN

CERTIFIED

C E R T I F I E D

�����
����������
�����

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CDV Series Direct Vent Gas Fireplace; PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS; Table of Contents; Logs

2 CDV Series Direct Vent Gas Fireplace 20010175 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure...

Page 3 - OFF; PLEASE REVIEW THE FOLLOWING CAREFULLY; Locating Your Fireplace; Installation & Operating Instructions; Proposition 65 Warning:

3 CDV Series Direct Vent Gas Fireplace 20010175 This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current ...

Page 4 - Fireplace Dimensions - Rear Vent; Fireplace specifications and framing dimensions.; Framing Dimensions

4 CDV Series Direct Vent Gas Fireplace 20010175 O F X - Rough Opening Width Rough Opening Height Rough Opening Depth U U V T W G I H J E A Y B K L Q Gas Line Access Gas Line Access Low Voltage Electrical Access Electrical Access D CL Centerline of 7" Collar N Low Voltage Access P RS C M 10175 CD...

Other Vermont Casting Models

All Vermont Casting Other