Page 2 - CDV Series Direct Vent Gas Fireplace; PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS; Table of Contents; Logs
2 CDV Series Direct Vent Gas Fireplace 20010175 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace.IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure...
Page 3 - OFF; PLEASE REVIEW THE FOLLOWING CAREFULLY; Locating Your Fireplace; Installation & Operating Instructions; Proposition 65 Warning:
3 CDV Series Direct Vent Gas Fireplace 20010175 This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current ...
Page 4 - Fireplace Dimensions - Rear Vent; Fireplace specifications and framing dimensions.; Framing Dimensions
4 CDV Series Direct Vent Gas Fireplace 20010175 O F X - Rough Opening Width Rough Opening Height Rough Opening Depth U U V T W G I H J E A Y B K L Q Gas Line Access Gas Line Access Low Voltage Electrical Access Electrical Access D CL Centerline of 7" Collar N Low Voltage Access P RS C M 10175 CD...
Page 5 - Fireplace Dimensions - Top Vent
5 CDV Series Direct Vent Gas Fireplace 20010175 O F X - Rough Opening Width Rough Opening Height Rough Opening Depth U U V T W G J E A Y B K L Q Gas Line Access Gas Line Access Low Voltage Electrical Access Electrical Access D N Low Voltage Access P RS C M 10 CDVT specs 1/06 H Fireplace Dimensions -...
Page 6 - Hearth; Mantel; Combustible mantel leg minimum installation.; Mantel Chart; Mantel Shelf or; Combustible mantel minimum installation.
6 CDV Series Direct Vent Gas Fireplace 20010175 Top of Unit to Ceiling ............................... 36” (914 mm)Front of Unit to Combustibles .................. 36” (914 mm) Appliance Top .......................................................... 0” (0 mm) Bottom ....................................
Page 7 - DO NOT; Final Finishing; Vented Gas Fireplace Heaters; Framing and Finishing; must; Gas Specifications; flange location; Flange Location for Desired; standoff location; Standoff Location for Desired Drywall Depth at Header; Hood Installation; CAUTION: Hood MUST be permanently installed.
7 CDV Series Direct Vent Gas Fireplace 20010175 Noncombustible materials such as brick or tile may be extended over the edges of the face of the fireplace. DO NOT cover any vent or grille panels. If a Trim Kit is going to be installed on the fireplace, the brick or tile will have to be installed flush ...
Page 8 - Installation; INSTA VENT FREE; Typical gas supply installation.; Remote switch; Remote switch wiring diagram.; 20V Electrical Hook Up
8 CDV Series Direct Vent Gas Fireplace 20010175 Installation 1. Carefully unwrap the remote wire that is attached to the valve. There are two 1/2” (13 mm) knockouts, one on each side of the outer casing. 2. Remove the knockout desired and insert the plastic snap bushing on the remote wire in the 1/2...
Page 9 - electric cover plate and secure.; Electric receptacle.; General Venting; There must not be any obstruction
9 CDV Series Direct Vent Gas Fireplace 20010175 The electrical junction box has been fitted standard on this model to allow for the easy connection of an op-tional fan kit. To connect the electric box to the house electrical sup-ply follow the steps below.1. Unscrew the retaining screw holding the el...
Page 10 - General Venting Information - Termination Location; Canadian Installations
10 CDV Series Direct Vent Gas Fireplace 20010175 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I ����� ������ ����� ������ �������� �������� ����� ������ V B CFM145a DV Termin Location 5/01/01 Rev. 12/05/01 sta INSIDE CORNER ...
Page 11 - Termination Clearances; Canadian Installations:; Flex Vent Pipes; Termination clearances.; Apply high temperature sealant to 4” and 7” pipes.
11 CDV Series Direct Vent Gas Fireplace 20010175 Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. A = Combustible 6"(152mm)Noncombustible 2"(50mm) B = Combustible 6"(152mm)Noncombustible 2"(50mm) A...
Page 12 - How to Use the Vent Graph; Horizontal dimension from the outside face of the; ertical dimension from the fl; DV Graphic; Rear Wall Venting Applications; Twist Lock Pipes; 6CDVR Venting
12 CDV Series Direct Vent Gas Fireplace 20010175 The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.1. Determine the height of the center of the horizontal vent pipe...
Page 13 - Top View; Rear vent applications.; Rear Wall Installation; Combustible Walls; Cut a 9; Noncombustible Walls; Hole opening must; Vent Opening; Vent Opening for Combustible Wall; Locate vent opening on wall.; Install interior firestop as shown in Figure 14.; Side View Vent Termination; Slide fireplace into position.
13 CDV Series Direct Vent Gas Fireplace 20010175 Top View Straight Venting Fig. 12 Rear vent applications. 13" (330 mm) Max. ����������������������������� FP1598 Rear Wall Installation Twist Lock Pipe STEP 1 Locate vent opening on the wall. To locate hole center consult with appropriate fireplace...
Page 14 - Rear Wall Vent Installations -; Locate the center of the hole 29; Grasp the vent pipe close to the collar and bend to
14 CDV Series Direct Vent Gas Fireplace 20010175 Rear Wall Vent Installations - 45° Flex Vent Pipe NOTE: Under no circumstances can ridged pipe or a rigid 45° elbow be used. The 7TCDV45KT must be used in a corner installation. The corner placement dimensions on Page 4 of the manual must be ad-hered ...
Page 15 - Secure collar in place, slide termination into collar.; Rear Wall Vent Application; Locate the hole 27; The centerline of the termination must be 27; Vertical Sidewall Applications
15 CDV Series Direct Vent Gas Fireplace 20010175 �������������������� Screw Collar Screws FP1605 Fig. 19 Secure collar in place, slide termination into collar. Flex Vent Rear Wall Vent Application * Exterior Outside Wall 20” - 32” (508 - 813 mm) From Rear of Unit * 1. Determine where the termination...
Page 16 - Maximum vent run with elbows.; Maximum number of elbows.; Vertical Sidewall Installation; Opening for Noncombustible Wall; Maximum horizontal vent run.; •IMPORTANT•; Minimum clearance between vent
16 CDV Series Direct Vent Gas Fireplace 20010175 V584-201 Horizontal Run 2/99 djt 10 ft. (3048 mm) 7 ft. 6 in. (2286 mm) 7 ft. (2134 mm) CFM147 Fig. 23 Maximum vent run with elbows. 90° Elbow = 3 ft. A + B = 17 ft. (Max.) 1 2 3 4 1 + 2 + 3 + 4 = 270 o CFM132 Insert Rear Vent Sidewall 2/26/01 sta CFM...
Page 17 - Measure horizontal length including 2” overlap.; Always start vertical run with 7TCDV90 on 36CDVR; Apply high temperature sealant.
17 CDV Series Direct Vent Gas Fireplace 20010175 STEP 2 Slide venting component on collar of fireplace. Secure component to fireplace by running a screw (self-tap-ping) through tab & into outer casing. (Fig. 26) STEP 3 Measure the horizontal length requirement including a 2” (51 mm) overlap, i.e. ...
Page 18 - Below Grade Installations; Ensure sidewall venting clearances are observed.; Snorkel; Snorkel installation, recessed foundation.; Below grade installation; Below grade installation.; Up to two 45° elbows may be used within the
18 CDV Series Direct Vent Gas Fireplace 20010175 Below Grade Installations When it is not possible to meet the required vent ter-minal clearances of 12” (305 mm) above grade level a snorkel vent kit #7TDVSNORK is required. It allows installation depth of down to 7” (178 mm) below grade level. The 7”...
Page 19 - Typical vertical; Typical vertical roof applications.; above and mark position.
19 CDV Series Direct Vent Gas Fireplace 20010175 Example: Maximum horizontal length 0 x 45° elbows = 10’ (3 m) 1 x 45° elbows = 8 ¹⁄₂ ’ (2.6 m) 2 x 45° elbows = 7’ (2.1 m)3. A minimum of an 8’ vertical rise.4. Two sets of 45° elbows offsets within these vertical installations. From 0 to a maximum of...
Page 20 - Minimum termination to roof clearance.; 6CDVT Vertical Venting
20 CDV Series Direct Vent Gas Fireplace 20010175 FP1022 Typical Straight Up Installation 1/26/00 djt 50’ (15 m) Storm Collar Roof Flash- ing Vent Termination Roof 2’ Min. Roof Support Attic Insulation Shield Attic Insulation Joists Joists FP1022 Fig. 36 Typical straight-up installation. Min. 2' (610...
Page 21 - Support straps for horizontal runs.; According to the chart the maximum
21 CDV Series Direct Vent Gas Fireplace 20010175 FP1012 Top vent max run 1/25/00 djt 20' (6m) 7.5' (2.3m) Pipe Straps Every 3’ (914mm) Firestop/Zero Clearance Sleeve Pipe Straps Every 3’ (914mm) FP1012 Fig. 39 Support straps for horizontal runs. Since it is very important that the vent-ing system ma...
Page 22 - Maximum number of elbow degrees.; Noncombustible Walls:; Vertical Sidewall Installations; cal height (X) required from the base of the flue collars; Vertical height requirement.
22 CDV Series Direct Vent Gas Fireplace 20010175 1 2 3 4 Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° Total angular variation = 270° 1 + 2 + 3 + 4 = 270° FP1239 Fig. 42 Maximum number of elbow degrees. STEP 1 Locate vent opening on the wall. It may be necessary to first position t...
Page 23 - Apply high temperature sealant to collars or termina-; pipe coming through the wall.
23 CDV Series Direct Vent Gas Fireplace 20010175 STEP 5 Use appropriate length of pipe sections - telescopic or fixed - and install the horizontal vent sections. The sec-tions which go through the wall are packaged with the starter kit, and can be cut to suit if necessary. (Fig. 46) Sealing vent pipe...
Page 24 - Top Vent; This Gas Fireplace has been approved for:; through the roof
24 CDV Series Direct Vent Gas Fireplace 20010175 BG402a Top Vent Below grade installation 1/26/00 djt Firestop 7” Pipe 7TDVSNORK (Snorkel) 4” (102mm) Clearance Min. Window Well Gravel Drain BG402 Fig. 48 Below grade installation. Zero Clearance Sleeve (if required) *A minimum of 24” (610mm) ver- tic...
Page 25 - Typical offset application.; Typical ceiling/roof support; Typical Roof Support; Roof and ceiling supports.
25 CDV Series Direct Vent Gas Fireplace 20010175 1 2 3 4 Max. 8' (2.4m) FP1245 through the roof 90 & 45 degree 12/02 1 + 2 + 3 + 4 = 270° FP1245 Fig. 51 Typical offset application. Vertical Through-the-Roof Installation 1. Locate your fireplace.2. Plumb to center of the (4” (102 mm) flue collar fr...
Page 27 - Vent Components; Venting Components; Elbow; Vent components; Must order a 7TCDV90 elbow
27 CDV Series Direct Vent Gas Fireplace 20010175 Venting Components 584G Venting Components Firestop spacer 2/25/99 djt 584H Venting components attic insulation shield 2/25/99 djt 584I vent components offset support 2/25/99 djt 584D Vent Components 90 degree elbow 2/25/99 djt 10/20/99 twist lock 584...
Page 28 - the window frame assembly by pulling down on the; Operating Instructions; Glass Information; Louvre removal; Remove top louvre; remove glass frame; Window frame assembly removal.
28 CDV Series Direct Vent Gas Fireplace 20010175 Only glass approved by CFM Corporation should be used on this fireplace. The top louvre panel is removed by lifting the panel vertically and pulling it away from the appliance. (Fig. 56) The lower access door is removed in the same manner. 1. Turn the ...
Page 29 - Flame adjustment knob for SIT valve.; bottom; Log Front; 6CDV burner flame appearance.
29 CDV Series Direct Vent Gas Fireplace 20010175 Logs The 36CDV logs are shipped in place. If a log is bro-ken, refer to the replacement parts list for a replace-ment. Figure 58 shows where the logs are secured to the fireplace. RN/RP & EN/EP Models For units equipped with “HI/LO” valves the flame...
Page 30 - FOR YOUR SAFETY READ BEFORE LIGHTING; Follow the gas supplier’s instructions.; To Turn Off Gas to Fireplace; Lighting and Operating Instructions; Lighting Instructions; Euro SIT
30 CDV Series Direct Vent Gas Fireplace 20010175 3. Open control access panel.4. Push in gas control knob slightly and turn clock- wise to “OFF”. Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.3. For MN/MP/TN/...
Page 31 - For Fireplaces equipped with SIT822 Gas Valve (EN or EP)
31 CDV Series Direct Vent Gas Fireplace 20010175 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. B. BEFORE OPERATING, smell a...
Page 32 - SYMPTOM; NOTE; SIT NOVA 820 MILLIVOLT VALVE
32 CDV Series Direct Vent Gas Fireplace 20010175 WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Spark ignitor will not light A. Defective or misaligned Using a match, light pilot. If pilot lights, turn off electrode at pilot. pilo...
Page 33 - SIT top Convertible Pilot; Fuel Conversion Instructions; Nova SIT820 Gas Valve.
33 CDV Series Direct Vent Gas Fireplace 20010175 The conversion of this appliance from one gas to another must be carried out by an authorized service provider. 1. Disconnect power to the unit and shut off the gas sup- ply. 2. Remove window frame assembly.3. Carefully remove the logs & lava rock...
Page 34 - Burner and Burner Compartment; Cleaning the Standing; If repair is necessary, it should; Maintenance
34 CDV Series Direct Vent Gas Fireplace 20010175 Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and refit the lo...
Page 35 - CDV; b. Log Middle Assy
35 CDV Series Direct Vent Gas Fireplace 20010175 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. CDV 16 14a,b 13 22 2 6a,b 7 10 11 12 15 17 19 21 20 23 24 25 3 8 18 26 1a 1b 1c Ref. Descri...
Page 36 - Clamp Frame Window; Fuel Conversion Kits
36 CDV Series Direct Vent Gas Fireplace 20010175 CDV (continued) 15. Flexible Gas Line w/ON/Off Shut-Off Valve 20002500 16. Fan Assy (FK12 Option) ZA1110 17. Electrical Cord (6 ft.) 51865 18. Door Assy 20010207 19. Glass w/Gasket 10010206 20. Gasket Glass 10000992 21. Frame Window 20010320 22. Clamp...
Page 37 - Specifications; Optional Accessories Available; Fan Kits; fan install; FK12 fan placement.; Wiring Instructions; Model
37 CDV Series Direct Vent Gas Fireplace 20010175 FK12 This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK12 Fan Assembly is a fixed speed fan system and does not allow for variable speed control. Specifications 115 Volts / 60 Hz / 56 Watts. Maintenance The f...
Page 39 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
39 CDV Series Direct Vent Gas Fireplace 20010175 BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purc...
Page 40 - CFM Corporation; Efficiency Ratings
2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com CFM Corporation Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 36CDVRRN 66.9 76 76.5 63 36CDVRRP 66.9 77 78 63