Page 2 - Vermont Castings Seville; Introduction; Save These Instructions For Future Reference.; Table of Contents; #1889 Bottom Heat Shield Kit
2 Vermont Castings Seville 30001490 Introduction Thank you for choosing a Vermont Castings Seville to meet your heating needs.We're confident you will find the Seville to be an effective wood-burning heater incorporatingmodern, non-catalytic combustion technology with the classic aesthetic appeal of...
Page 3 - Specifications; This value can vary depending on how the stove is; Drawings not to scale.
3 Vermont Castings Seville 30001490 Specifications Seville, Model 1635 Maximum heat output ......................... 30,000 Btu’s/hr. 1 Area heated ...................................... Up to 1320 sq. ft. 2 Fuel size/type ...................................... 18” (46 cm) logs Loading ................
Page 4 - Chimneys; Installation; Masonry Chimneys
4 Vermont Castings Seville 30001490 Chimneys Your stove must be connected either to a soundmasonry chimney that meets local codes, to a relinedmasonry chimney that meets local codes, or to anapproved prefabricated metal chimney. Whichever ofthose types you use, the chimney and chimney con-nector mus...
Page 5 - • Unused openings in an existing masonry chimney; Prefabricated Chimneys; High Temperature (650; Chimney Size; elbows. Slope horizontal
5 Vermont Castings Seville 30001490 Masonry Chimneys, cont'd. • Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of thechimney wall, and the chimney liner should berepaired. Openings sealed with pie plates orwallpaper are a hazard and should be sealed withm...
Page 7 - Connection Above the Fireplace; Double-check connector clearance to the ceiling.; Alternate methods approved by the NFPA:
7 Vermont Castings Seville 30001490 Connection Above the Fireplace In this installation, the chimney connector enters thefireplace flue though a thimble located above thefireplace. (Fig. 6) The liner of the fireplace chimneyshould extend at least to the point at which the chim-ney connector enters t...
Page 9 - Floor Protection; Floor Protection Requirements
9 Vermont Castings Seville 30001490 Floor Protection A tremendous amount of heat radiates from thebottom plate of your Madison. The floor area directlyunder and around the stove will require protection fromradiant heat as well as from stray sparks or embersthat may escape the firebox. Heat protectio...
Page 10 - Wall Shields
10 Vermont Castings Seville 30001490 Wall Shields Wall shields should be constructed of 24 gauge orheavier sheet metal, or another noncombustiblematerial such as 1/2" (13mm) insulation board (Fig. 14)or common brick "laid on flat," with the 3 ¹⁄₂ " (90mm) side down. Shields must be s...
Page 12 - Seville 1635 Clearance Chart; STOVE CLEARANCE
12 Vermont Castings Seville 30001490 Seville 1635 Clearance Chart Use the chart below together with the diagrams on the next page to determine the minimum clearance required foryour particular installation. In any case, it is always advisable to locate the stove as far away from walls as pos-sible i...
Page 13 - Alcove Installations
13 Vermont Castings Seville 30001490 Alcove Installations The Seville is approved for installation into an alcoveconstructed to maintain the clearances diagramed inFigure 18. Fig. 18 Alcove specifications. Unprotected Surfaces Protected Surfaces (per NFPA 211) A Min. Width B Max. Depth C Stovetop to...
Page 14 - Unpack the Stove; Assembly
14 Vermont Castings Seville 30001490 You will need the following tools to assemble the Seville:• 7/16" open end wrench • safety glasses & gloves• flat head screwdriver • power drill w/ 1/8" (3mm) bit • stub handle phillips screwdriver Unpack the Stove 1. Remove the shipping straps and pl...
Page 15 - Position the Fan body within the Rear Shroud as
15 Vermont Castings Seville 30001490 Install the Fan 1. Position the Fan body within the Rear Shroud as shown in Figure 20. The Fan’s upper flange shouldbe located behind the lip of the opening. Secure theFan to the Shroud using five sheet metal screwsand single star washer supplied with the kit. In...
Page 16 - Attach the Chimney Connector
16 Vermont Castings Seville 30001490 Attach the Chimney Connector 1. If you have not already done so, remove the Outer Top Plate by simply lifting it off of the stove body. 2. Insert the crimped end of the first section of chimney connector into the flue collar. Using the holes in thecollar as guide...
Page 17 - multi-ported tubes located at the top of the firebox.; Burn Only High-Quality Wood; Operation
17 Vermont Castings Seville 30001490 Air enters the stove through two, unrestricted inletsand is heated while passing through separate channelsbefore being delivered through four stainless steel multi-ported tubes located at the top of the firebox. Burn Only High-Quality Wood THE SEVILLE IS DESIGNED...
Page 18 - SEVILLE CONTROL SETTINGS; Burn Rate Primary Air Control Shutter Position; Starting and Maintaining a Fire; MEDIUM
18 Vermont Castings Seville 30001490 In newer homes that are well-insulated and weather-tight, poor draft may result from insufficient air in thehouse. In such cases, a slightly opened window nearthe stove on the windward side of the house willprovide the fresh air needed. A more effective option fo...
Page 19 - Step 2. Place several sheets of crumpled newspaper; NOTE: Some chimneys need to be “primed,” or; Step 4. After the stove has been broken-in using
19 Vermont Castings Seville 30001490 The Primary Air Inlet must be open when starting afire or when refueling. Step 1. Open the primary air control fully. (Lever at 7:00) Step 2. Place several sheets of crumpled newspaper in the stove. Avoid using glossy or colored paper,as these burn poorly. At the...
Page 20 - Refuel While the Embers Are Still Hot; Step 2. Open the door and check the ash level in the; Ash Disposal
20 Vermont Castings Seville 30001490 Refuel While the Embers Are Still Hot Reload the Seville while it is still hot and there areplenty of glowing embers to rekindle the fire. Includesome smaller pieces of wood in the new load of fuel tohelp the stove return to its operating temperaturequickly. Wear...
Page 21 - Care of the Cast Iron Surface; • Be sure the glass is completely cool.; Glass Replacement; Inspect the Gasket. If the window gasket is in good; Gasket Replacement; Gasket Size; Maintenance
21 Vermont Castings Seville 30001490 Let the fire in the stove go out and allow the stove tocool completely before beginning any maintenanceprocedure. Care of the Cast Iron Surface An occasional dusting with a dry rag will keep thepainted cast iron of your Seville looking new. The stove’s paint can ...
Page 22 - Adjust the Door; The Chimney System; Creosote; • Close the thermostat lever.
22 Vermont Castings Seville 30001490 Step 7. Press the gasketed part firmly against itsnormal mating surface to seat the gasket evenly in itschannel. Close and latch the door to do this; close thedoor on a piece of waxed paper to keep the cementfrom migrating onto the non-gasketed part, or maskother...
Page 23 - Annual Maintenance; Draft Management; Masonry Chimney
23 Vermont Castings Seville 30001490 Annual Maintenance Perform a thorough cleaning, inspection and repaireach Spring, at the end of the heating season. • Thoroughly clean the chimney and chimney connec- tor. • Inspect the chimney for damage and deterioration. Replace weak sections of prefabricated ...
Page 25 - F. Creosote is volatile and; Backpuffing
25 Vermont Castings Seville 30001490 You can judge the moisture content of wood by itsappearance and weight or use a commercially avail-able moisture meter for an exact measurement.Unseasoned wood will be a third heavier than drywood. Also, look for cracks (‘checking’) in the ends ofthe log that res...
Page 26 - Seville Woodburning Stove
26 Vermont Castings Seville 30001490 18 19 20 18 19 20 18 19 20 13 14 25 32 18 31 30 29 34 36 35 36 34 33 26 26 24 1 2 28 4 39 46 41 40 43 16 39 5 6 11 12 3 3 38 37 44 7 17 8 22 15 9 10 21 23 9a 10a Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specific...
Page 27 - Use only Vermont Castings Glass Panel part
27 Vermont Castings Seville 30001490 Seville 1635 (continued) Item/Model Number Part Number 0-05 Notes: 1. In this diagram and throughout this manual, 'left' and 'right' mean as you face the stove. 2. Use only Vermont Castings Glass Panel part number 30000774 for replacement. 3. Part numbers for cas...
Page 28 - HOW TO OBTAIN SERVICE; Warranty; LIMITED 3 YEAR WARRANTY; LIMITED 1 YEAR WARRANTY; EXCLUSIONS & LIMITATIONS; Vermont Castings, Majestic Products
28 Vermont Castings Seville 30001490 ©Vermont Castings, Majestic Products 4. This warranty does not cover a stove repaired bysomeone other than a Vermont Castings Majestic ProductsCompany Authorized Dealer. 5. Damage to the unit while in transit is not covered by thiswarranty but is subject to claim...