Installation instructions

Ceiling hood
Operating mode: extracted air
Range hood DSDSR12

J64003113-R03

28/01/2016

1

The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.

Validity

These installation instructions apply to:

64003

(DSDSR12, construction width 120 cm)

General notes

If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances),
safe operation is only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at
the location of the appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in
doors or windows and in combination with an air-intake/exhaust-air wall box or by other technical means.

If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the min-
imum distances (see section «Dimensions») must be adhered to.

Efficient repairs can only be guaranteed if it is possible to uninstall the complete appliance at any time without
causing any damage.

Identification plate

Remove the grease filters. The identification plate is located on the inside of the appliance.

Installation accessories supplied

All fixing elements are contained in the scope of delivery.

Extraction mode

The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burn-
ing gas or other fuels.
Observe the local fire regulations.

Electrical connections

Electrical connections must be carried out by qualified personnel in accordance with the guidelines and
standards for low-voltage installations and the specifications of the local electricity supply companies.

A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to spe-
cifications. An all-pole mains isolating device with 3 mm contact opening should be provided in the house wir-
ing system. Switches, plug and socket devices, circuit breakers and fusible cut-outs which are accessible after
installation and which have all-poles switching are permissible as isolating devices. Effective earthing and sep-
arately installed neutral and earth conductors ensure safe and fault-free operation. After installation, live parts
and cables with basic insulation must not be accessible. Check old installations.

The appliance is designed for use up to a max. altitude of 2000 m above sea level.

Refer to the identification plate for information on the required mains voltage, current type and fuse protection.

The mains plug must not be cut off.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Distance above hob; Installation; Installation with built-in motor

Installation instructions Ceiling hoodOperating mode: extracted airRange hood DSDSR12 J64003113-R03 28/01/2016 2 Dimensions Ø 150 1200 1170 318 670 700 210 A 133 A X Cut-out measurements 1178±2 675± 2 Distance above hob Minimum distance X above hob: min. 800 mm Maximum recommended distance: 1300 mm ...

Page 3 - Installation instructions; Installation with external motor

Installation instructions Ceiling hoodOperating mode: extracted airRange hood DSDSR12 J64003113-R03 28/01/2016 3 Installation with external motor Accessories set H43403 is required (not in scope of delivery). 1. Screw lateral supports A upwards as far as possible be- fore they fold back in using scr...

Page 4 - Connection variants for ceiling range hoods

Installation instructions Ceiling hoodOperating mode: extracted airRange hood DSDSR12 J64003113-R03 28/01/2016 4 13. Pass the long cable through air intake housing half H and plug into the motor. D H 14. Screw air intake housing half H to motor housing D . Make sure they are correctly aligned. 15. C...

Other V-ZUG Range Hoods Models

All V-ZUG Range Hoods