V-ZUG DIPQG10C Range Hood – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Electrical connections; Do not cut off the plug.; Options connection; Installation instructions; Island hood
- Page 3 – Dimensions; Telescopic casing
- Page 4 – Installation; Note on installation; Exhaust air requires intake air.; Installing; Remove grease filter.
- Page 6 – ATTENTION! The combi filter is separately packaged.; Insert grease filter.
The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.
Validity
These installation instructions apply to:
63004 (DIPQG9, construction width 100 cm)
63005 (DIPQG12, construction width 120 cm)
H4.2608 (motor housing, extraction, standard)
H4.2604 (motor housing, recirculation, standard, island and wall hood)
H4.2605 (motor housing, recirculation, short, island and wall hood)
H4.2774 (motor housing, extraction with options connection)
General notes
If other firing systems are being used at the same time (e.g. wood, gas, oil or coal-fired heating appliances), safe operation is
only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or windows
and in combination with an air-intake/exhaust-air wall box or by other technical means.
If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the minimum distances
(see 'Dimensions') must be adhered to.
Efficient repairs can only be guaranteed if it is possible to uninstall the complete appliance at any time without causing any
damage.
Identification plate
Remove the grease filters. The identification plate is located on the inside of the appliance.
Supplied installation accessories
All fixing elements are contained in the scope of delivery.
Extraction mode
The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or other
fuels.
Observe the local fire regulations.
Installation instructions
J63004.113-0
Range hood DIPQG10/DIPQG12
02.09.14
Island hood
Operating mode: Extraction/recirculation
1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Electrical connections Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards for low-voltage installations and the specifications of the local electricity supply companies.A plug-in appliance may only be connected to a socket outlet with ea...
Dimensions Drilling plan (view X) 70 B A ø 150 1000/1200 700 h X 330 330 ¹ 324,8 297 240,4 180 80 240,4 293,5 324,8 20 180 55 100 R80 Telescopic casing Distance above hob (available in various heights) Minimum distance B: Height A: See planning aid for kitchen appliances For electric hob: min. 500 m...
Installation Note on installation • Ensure the correct layout of the exhaust air duct as well as an adequate supply of intake air. Exhaust air requires intake air. • Avoid routing the exhaust air pipeline to the side through the flue casing. • Planning features for non-destructive de-installation an...