UNIQUE UGP-30G OF2 S/S - User Manual

UNIQUE UGP-30G OF2 S/S

UNIQUE UGP-30G OF2 S/S Range – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
Page: / 49

Table of Contents:

  • Page 2 – OFF-GRID BY UNIQUE 30” PROPANE GAS RANGE; READ AND SAVE THESE INSTRUCTIONS; Installation & Owner’s Manual; This manual contains information for:; Important Safeguards; Important; TO THE OWNER OF THE RANGE: Retain this owner’s manual for future; How to Obtain Service and/or Parts
  • Page 3 – MANUFACTURED & CERTIFIED BY; UNIQUE APPLIANCES; WARNING; placing the range back in operation.
  • Page 4 – TABLE OF CONTENTS
  • Page 5 – WELCOME & CONGRATULATIONS; UNIQUE
  • Page 6 – IF YOU SMELL GAS; The California Safe Drinking Water and Toxic Enforcement Act
  • Page 7 – Be sure a qualified technician in accordance with the; TO REDUCE THE RISK OF TIPPING OF THE RANGE, THE RANGE MUST BE SECURED; leave the oven door open when the range is unattended.; backguard of a range.; Children climbing on the range to reach the items could be; Do not allow children to climb or play around the range.; The weight of a child on an
  • Page 11 – use in the event of a house fire.; must be practiced when operating and maintaining any appliance.; On sealed burner models never attempt to operate the surface
  • Page 12 – CARBON MONOXIDE WARNING; the Carbon Monoxide levels appropriate for each appliance.
  • Page 14 – INSTALLATION INSTRUCTIONS; Levelling a Free-Standing Range; Making sure the anti-tip bracket is installed:
  • Page 15 – HOW TO INSTALL THE BACKSPLASH
  • Page 16 – NOTICE TO MASSACHUSETTS APPLIANCE DEALERS:; State of Massachusetts.; NOTICE: Massachusetts law requires the following:; gas connector and; GAS CONNECTIONS
  • Page 17 – Installation
  • Page 18 – After installation
  • Page 19 – WALL CLEARANCES
  • Page 20 – Anti-Tip Bracket Location
  • Page 21 – The conversion kit must be installed by qualified service agency.; GAS RANGE CONVERSION; in the manufacturer’s instructions supplied with the kit.”
  • Page 22 – Convertible Pressure Regulator
  • Page 23 – See below for rating of orifice for each model; Adjustment location is; Natural Gas Orifices
  • Page 24 – correctly. Please refer to pages 21 through 24.
  • Page 25 – High Altitude Applications above 2,000 feet:; CHECKING FOR MANIFOLD GAS PRESSURE
  • Page 26 – ADJUSTING THE TOP BURNER AND OVEN FLAME; see adjustment procedure under; Cooktop Burner Operation
  • Page 27 – Oven Valve; to convert the range back to its original fuel.; Top Burner Height
  • Page 28 – Lighting the Top Burners; the knob down until the flame lights.; OPERATION OF RANGE; OFF; PUSH
  • Page 30 – CAUTION
  • Page 31 – ALIGNMENTS AND ADJUSTMENTS
  • Page 32 – Baking; temperatures up to 350°F and 30 minutes for temperatures up to 425°F.; Oven Racks; cookware is not directly over another.; Rack Removal; rack keeper and slide the rack to the rear.; Never cover the oven racks with aluminum foil; . Such practices will trap heat and
  • Page 34 – BROILING; Be; . Never leave a dirty broil pan in place, always; DO NOT USE THE BROILER AREA FOR STORAGE OF COOKWARES.; openings, so do not extend foil beyond oven bottom.; If you should get a heavy spillover on the oven bottom:; bottom to become wet.
  • Page 35 – sure to replace the parts correctly.; Knobs; can be used to shine the top.; CLEANING THE RANGE
  • Page 36 – result in an explosion or fire.; Aluminum Foil in Oven and Broiler; Never cover any slots, holes or passages in the oven bottom or cover; Cleaners and Cleaning Materials
  • Page 38 – Open the door to fully.; OR DOOR COULD BE DAMAGED.
  • Page 39 – HOW TO GAIN ACCESS TO THE BATTERY COMPARTMENT; Gaining access to the battery compartment:; reduce the number of times you will have to replace the batteries.; REMOVING THE KICKPLATE FOR CLEANING; cleaning underneath the range.
  • Page 40 – TROUBLESHOOTING; PROBLEM
  • Page 41 – WIRING DIAGRAM
  • Page 42 – PARTS DIAGRAM AND LIST
  • Page 46 – following information for future reference:
  • Page 47 – PROPANE GAS RANGE 1 YEAR LIMITED WARRANTY
  • Page 48 – Please visit our website for more quality Unique products:; RATING LABEL
Loading the manual

DEC21V1

OWNER’S GUIDE

serial number:

OFF-GRID BY UNIQUE

30” PROPANE GAS RANGE

(LPG & NG CONVERTIBLE)

MODEL NUMBER:

UGP-30G OF2 S/S,

Never Operate the Top Surface Cooking Section of
this Appliance Unattended

Failure to follow this warning statement could

result in fire, explosion, or burn hazard that could
cause property damage, personal injury, or death.

If a fire should occur, keep away from the appliance

and immediately call your fire department.
DO NOT ATTEMPT TO EXTINGUISH AN OIL/GREASE
FIRE WITH WATER.

WARNING:

Conforms to CSA/

ANSI STD Z21.1

2018 Certified to

CSA STD 1.1 2018

Household Cooking

Appliances.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - OFF-GRID BY UNIQUE 30” PROPANE GAS RANGE; READ AND SAVE THESE INSTRUCTIONS; Installation & Owner’s Manual; This manual contains information for:; Important Safeguards; Important; TO THE OWNER OF THE RANGE: Retain this owner’s manual for future; How to Obtain Service and/or Parts

OFF-GRID BY UNIQUE 30” PROPANE GAS RANGE LPG & NG CONVERTIBLE READ AND SAVE THESE INSTRUCTIONS The installation of the appliance must conform with local codes ANSI Z21.1b-2012, in the absence of local national Fuel Gas Code, ANSI Z233.1, and in Canada B149.2 Propane Storage and Handling Code Ins...

Page 3 - MANUFACTURED & CERTIFIED BY; UNIQUE APPLIANCES; WARNING; placing the range back in operation.

2245 Wyecroft Road #5 Oakville, Ontario, Canada L6L 5L7 Phone: 905-827-6154 Toll Free: 1-877-427-2266 Fax: 905-827-2027 www.UniqueAppliances.com MANUFACTURED & CERTIFIED BY UNIQUE APPLIANCES WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causin...

Page 4 - TABLE OF CONTENTS

4 IMPORTANT SAFEGUARDS . . . . . . . . . . . . . . . . . . . . . . . . 6CARBON MONOXIDE WARNING . . . . . . . . . . . . . . . . . . . . . 12ENERGY SAVING IDEAS . . . . . . . . . . . . . . . . . . . . . . . . . . 13INSTALLATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . 14HOW TO INSTALL...

Other UNIQUE Ranges Models

All UNIQUE Ranges