Tripp Lite SU8000RT3U - Manual
Tripp Lite SU8000RT3U – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – External Battery Configuration Software; Specifications; OUTPUT
- Page 3 – INPUT; Hardwire; BATTERY; Supports extended runtime with optional external battery packs; VOLTAGE REGULATION
- Page 4 – POSTRMKITHD; Primary form factor
- Page 5 – Cooling method; Fan; ENVIRONMENTAL; 0 dBA at front side 1 meter
- Page 6 – Included; LINE / BATTERY TRANSFER; ms. typical power failure response in optional economy mode; SPECIAL FEATURES; Cold-start operation supported; CERTIFICATIONS; -year limited warranty; Related Items; Optional Products
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
Model #: SU8000RT3U
SmartOnline 8kVA On-Line Double-Conversion UPS, 6U Rack/Tower, 200-240V NEMA outlets
Highlights
8kVA / 8000VA / 7200W on-line double-conversion UPS; 0.9 power factor
200/208/220/230/240V 50/60Hz output; Economy mode option
6U Rack/Tower compatible; Hot-swap power and battery modules
USB, RS232 & EPO ports; SNMP/WEB and contact-closure card options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hardwire input (3 wire); L6-30R & L6-20R outlets
Description
Tripp Lite SU8000RT3U 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical network
applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications.
Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with
manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced
availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers,
computer rooms, network closets and rugged industrial locations.
Package Includes
SU8000RT3UPM 3U UPS power module
BP240V10RT3U external battery pack
SUPDMB710 Detachable PDU with manual bypass switch
Four post compatible rack rail kit (2 sets)
Tower stands for upright tower configuration
PowerAlert software, complete data cabling and user manual
Features
Tripp Lite SU8000RT3U 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 6U total rack/tower configuration (3U UPS
power module and 3U external battery pack)
Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to
connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input; 2 L6-30R and 4 L6-20R outlets
Maximum installed rack depth of only 32.5 in. / 82.6cm inches
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions
and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with
enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS
types
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low as 100V and
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low as 100V and overvoltages as high as 300V Supports 50/60Hz operation for worldwide frequency compatibility Expandable runtime is supported with optional BP240V10RT3U; BP240V557C-1PH; BP24...
Frequencycompatibility details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to50Hz or 50Hz to 60Hz (no de-rating) Output voltageregulation (linemode) +/- 2% Output voltageregulation (Economyline mode) +/- 10% Output voltageregulation (Batter...
Overvoltagecorrection Corrects overvoltages up to 300V Undervoltagecorrection Corrects undervoltages as low as 100V LEDS ALARMS & SWITCHES LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCDscreen offers additional informatio...