Table of Contents:

  • Page 2 – Ultimate Lifetime Insurance; Specifications; SYSTEM OVERVIEW
  • Page 4 – Related Items
  • Page 5 – Surge Protectors; DCATV; Tower Stands; Tower Stand - Expandable Tower Base Stand UPS Accessory
Loading the manual

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail:

[email protected]

Model #: SU5000RT3UHV

SmartOnline Expandable Rack / Tower UPS System - Online, double-conversion protection for mission critical
applications

Highlights

5000VA online 5U rack / tower UPS (3U Power Module + 2U Battery Pack)

Zero transfer time, on-line, double-conversion and economy-mode operation

supported

Enhanced serial communications ports, SNMP/Web card slot and EPO jack

Maintains 200, 208, 220, 230 or 240V output +/-2% during brownouts to 156

and overvoltages to 276V

Expandable runtime with optional external battery packs

$250,000

Ultimate Lifetime Insurance

(USA, Puerto Rico & Canada only)

Description

Tripp Lite 5kVA Smart Online RM UPS. 5000VA on-line, double-conversion UPS for server, network and telecommunications equipment. Maintains

battery derived AC output during blackouts with active, full-time power conditioning. Fault-tolerant auto-bypass prevents unexpected service

interruptions during overload or internal fault conditions. 3U power module and 2U battery pack install in 5 rack spaces. Full-time sine wave output

within 2% of selectable 200/208/220/230/240V AC. Corrects brownouts to 156V and overvoltages to 276V. Frequency regulation locks output power

to 50/60Hz (+/-0.2%)/Expandable runtime with optional rackmount external battery packs. Double-conversion UPS converts raw input from AC to

DC, then back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve

power problems not addressed by other UPS types. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy

costs. Network-grade AC surge and noise suppression. Network management interfaces include 2 DB9 ports and SNMPWEBCARD slot. Supports

simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert

monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs and LCD readout with scroll controls support

visual monitoring of all major UPS functions. Audible alarm. Self test. 4-post rackmount accessories included; 2-9USTAND and 2POSTRMKITWM

accessories available. L6-30P plug-in connection; built-in L6-30 & L6-20 outlets. Power Distribution Unit (PDU) options supported. Field-replaceable,

hot-swappable external battery packs. Attractive all-black color scheme. 2-year warranty and $250,000

connected equipment insurance

; extended

warranty and service contracts available.

Applications

Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection. Common

applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems

Features

True online, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise

5000VA/3500 watt output power capacity compatible with 200-240V applications at 50/60 Hz

3U power module and 2U battery pack installs in any 19 inch rack enclosure using only 5 rack spaces

Double conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from

harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types

Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient

operation of critical servers, networking and telecommunications equipment

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Ultimate Lifetime Insurance; Specifications; SYSTEM OVERVIEW

Accepts input voltages between 156 and 276, regulating output within 2% of selected 200/208/220/230/240V nominal voltage Supports connected equipment during blackouts for 20/8 minutes at half/full load levels. Runtime is further expandable with optional external battery packs Network interfaces supp...

Page 4 - Related Items

LINE / BATTERY TRANSFER Transfer time fromline power to batterymode Zero, online UPS continuously converts incoming AC to DC, then back to AC. When line power is interrupted, UPSmaintains continuous output from battery reserves with absolutely no disruption in output AC power. Low voltage transferto...

Page 5 - Surge Protectors; DCATV; Tower Stands; Tower Stand - Expandable Tower Base Stand UPS Accessory

W02-BW0 Regular business hours start-up, excludes on-site warranty. Qty: [optional] W02-BW2-1BD Regular business hours start-up and two year on-site, next business day break/fixwarranty service for locations within 350 miles of a covered service area. Qty: [optional] W02-BW2-247 Regular business hou...