  • Page 2 – Specifications; OUTPUT
  • Page 4 – Yes; PHYSICAL; POSTRMKITHD; Primary form factor; Rackmount; Rack Height; Tower
  • Page 5 – Cooling method; Fans; ENVIRONMENTAL; 0 dBA at front side 1 meter; COMMUNICATIONS; Included; LINE / BATTERY TRANSFER
  • Page 6 – Related Items; Optional Products; SNMPWEBCARD
Loading the manual

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail:

[email protected]

Model Number: SU20KRTHW

SmartOnline 20kVA On-Line Double-Conversion UPS, N+1, 12U Rack/Tower, 200-240V Hardwire output

Highlights

20kVA / 20,000VA / 18,000W on-line double-conversion UPS; 0.9 power factor

200/208/220/230/240V 50/60Hz output; Economy mode option

Hot-swap power and battery modules, N+1 fault tolerance at loads up to 10kVA

USB, RS232 & EPO ports; support for SNMP/WEB and contact-closure card

options

Front panel LEDs with detailed LCD monitoring and control screen

Expandable runtime with optional external battery packs

Hardwire input (3 wire); Hardwire output

Description

Tripp Lite SU20KRTHW 20,000VA / 20kVA / 18,000 watt online, double-conversion UPS system offers complete power protection for critical server,

network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads

up to 10kVA, and non-redundant operation at loads between 10 and 20kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions

during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major

UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement

options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

Package Includes

Two SU10000RT3UPM UPS power modules

Two BP240V10RT3U battery packs

SUPDMB20KHW PDU with Bypass switch

4-post rackmount installation rails

PowerAlert software and cabling

Features

Tripp Lite SU20KRTHW 20kVA, 20,000VA / 18,000 watt on-line, double-conversion UPS system in 12U total rack/tower configuration

Unique configuration offers 20kVA non-redundant operation and automatic N+1 redundancy at load levels of 10kVA and under

Included Parallel PDU with manual bypass switch enables hot-swap replacement power modules at any supported load level

Hardwire input and output connections

Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal

Supports 50/60Hz operation for worldwide frequency compatibility

Expandable runtime with optional external battery packs

Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)

Battery independent restart

Highly efficient economy mode option

Optional SNMPWEBCARD, RELAYIOCARD and RELAYIOMINI interface modules available (RELAYIOMINI requires removal of USB

interface module)

HID-compliant USB interface

Includes Free PowerAlert monitoring software; PowerAlert LOCAL, PowerAlert NSA and PowerAlert NMS for monitoring up to 250

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Specifications; OUTPUT

SNMP-enabled UPS, PDU and other networking devices Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required) Optional 2-9USTAND supports upright tower placement (2 required) Supports Emergency Power Off (EPO) via built-in interface Front panel LEDs and LCD readout with scroll ...

Page 4 - Yes; PHYSICAL; POSTRMKITHD; Primary form factor; Rackmount; Rack Height; Tower

EMI / RFI AC noisesuppression Yes PHYSICAL Included mountingaccessorydescription 4 sets of adjustable 4 post rack rails included (one for each included 3U module) Installation formfactors supportedwith optionalaccessories 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND) Optional mountingaccessory ...

Page 5 - Cooling method; Fans; ENVIRONMENTAL; 0 dBA at front side 1 meter; COMMUNICATIONS; Included; LINE / BATTERY TRANSFER

UPS Shippingdimensions (heightx width x depth / cm) 91.4 x 102.2 x 129.5 Shipping weight (lbs) 600 Shipping weight (kg) 272.4 Cooling method Fans UPS housingmaterial Steel ENVIRONMENTAL OperatingTemperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius StorageTemperature Range +5 t...