Tripp Lite SM1000RMNAFTA - Manual

Tripp Lite SM1000RMNAFTA

Tripp Lite SM1000RMNAFTA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
Page: / 5

Table of Contents:

  • Page 2 – Ultimate Lifetime Insurance; Specifications; SYSTEM OVERVIEW
  • Page 3 – VOLTAGE REGULATION; Input voltages between 83 and 107 are boosted by 14%; LEDS ALARMS & SWITCHES; Instantaneous; PHYSICAL; Steel; ENVIRONMENTAL
  • Page 4 – Related Items
Loading the manual

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail:

[email protected]

Model #: SM1000RMNAFTA

Smart Pro Rack/Tower UPS - NAFTA assembled version of SMART1000RM2U

Highlights

1000VA / 1kVA line interactive 1U rackmount UPS

Maintains sine-wave 120V nominal output over an input range of 83 to 147V

Network communications supported via USB port, serial port, SNMP/Web card

slot and EPO interface

Current monitoring and switched PDU control via 2 single-outlet load banks

Input: NEMA 5-15P (120V 15A) / Output: 6 NEMA 5-15R (120V)

2 year product warranty / $250,000 Ultimate Lifetime Insurance (USA, Puerto

Rico & Canada only)

Description

1000VA line interactive UPS for server, network and telecommunications equipment/1U rackmount form factor/Corrects brownouts and

overvoltages from 83 to 147/Sine wave output in both AC and battery mode/Uninterruptible Power Supply (UPS) maintains battery derived AC output

during blackouts and severe voltage fluctuations/NEMA 5-15P input plug/Network-grade AC surge and noise suppression/Network management

interfaces includes USB port, DB9 serial port and SNMPWEBCARD slot/Supports simultaneous detailed monitoring of equipment load levels,

self-test data and mains power conditions via all 3 network interfaces at once/Includes PowerAlert monitoring software and complete

cabling/Emergency Power Off (EPO) interface/Integrated 2 bank switched PDU/3 stage metered current monitoring and battery charge LEDs/Mains

power and voltage regulation LEDs/Audible alarm/Self-test/Supports 2 or 4 post rackmount installation/Field replaceable, hot swappable internal

batteries/Attractive all-black UPS design/Two year warranty with $250,000

connected equipment insurance

/Extended warranty and service contracts

available

Applications

Ideal for protection of fileservers, network accessories and telecommunications equipment in server rooms, internetworking closets,

co-location racks, kiosks and a variety of other locations. Common applications include any mix of servers, workstations, hubs, routers,

concentrators, IP telephony and traditional PBX switching systems.

Package Includes

SM1000RMNAFTA UPS System

Mounting hardware

Cabling for USB & DB9 monitoring and EPO switching

PowerAlert unattended shutdown and UPS/Power monitoring software

Warranty information and instruction manual

Features

1000VA/640 watt output power capacity compatible with North American 120V/60Hz power

1U rackmount UPS installs in standard 2 or 4 post 19 inch racks with a depth of only 16.75 inches

Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges

Regulation (AVR) corrects inputs from 83-147VAC back to usable 120V levels without consuming battery power

Line interactive Automatic Voltage Regulation (AVR) corrects inputs from AVR circuits boost undervoltages by 14% depending on the

severity and reduces overvoltages by 12%

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Ultimate Lifetime Insurance; Specifications; SYSTEM OVERVIEW

Network interfaces support simultaneous communications via USB, DB9 serial and SNMPWEBCARD slot Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP Communications ports suppor...

Page 3 - VOLTAGE REGULATION; Input voltages between 83 and 107 are boosted by 14%; LEDS ALARMS & SWITCHES; Instantaneous; PHYSICAL; Steel; ENVIRONMENTAL

ReplacementBattery Cartridge RBC64-1U VOLTAGE REGULATION Voltage regulationdescription Line interactive voltage regulation system corrects input voltages between 83 and 147 back to usable 120V nominallevels. Overvoltagecorrection Input voltages between 128 and 147 are reduced by 12% Brownout correct...

Page 4 - Related Items

Battery modeBTU/hr. (Max.) 189.2 COMMUNICATIONS Network monitoringport Includes 2 built-in monitoring ports, 1-USB & 1-DB9. Each supports on battery, low battery, power restored, AC linevoltage, DC battery voltage, load percentage, battery charge current, battery capacity, internal UPS temperatu...

Other Tripp Lite Models

All Tripp Lite Other