Tripp Lite 240/415V AC - Manual

Tripp Lite 240/415V AC

Tripp Lite 240/415V AC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
Page: / 56

Table of Contents:

  • Page 2 – Important Safety Warnings; UPS Location Warnings; UPS Connection Warnings; Equipment Connection Warnings; Important
  • Page 3 – Control Panel
  • Page 4 – Breakers, Switches and Fuses; Front Panel, Door Open
  • Page 5 – Installation; Installation Checklist
  • Page 6 – Parallel Wiring Diagrams; Electrical Connection; Connection Checklist; For; Recommended Cable Sizes, Torque Specifications; and; Terminal Wiring Diagrams; refer to the
  • Page 7 – Single UPS Operation; • Operational Modes; Operational Modes
  • Page 9 – Shutdown Procedure
  • Page 15 – LCD Display Navigation
  • Page 16 – “Parameter Setting” Sub-Menu
  • Page 17 – “System Control” Sub-Menu
  • Page 18 – “Other Information” Sub-Menu
  • Page 19 – Communications
  • Page 20 – Ethernet Power; GENERATOR CONTACT
  • Page 21 – UPS Parallel Communication Ports; TERMINAL RESISTOR FOR RS-485; UPS Parallel Communication Port
  • Page 23 – Manual del propietario; No-break inteligente trifásico realmente en; El módulo de batería se describe en su; English
  • Page 24 – Advertencias de seguridad importantes; Advertencias sobre la ubicación del no-break; Advertencias sobre la batería
  • Page 25 – Panel de Control; PANEL DE CONTROL
  • Page 26 – Interruptores automáticos, interruptores y fusibles; PANEL FRONTAL, PUERTA ABIERTA; Características del módulo de potencia
  • Page 27 – Instalación; Lista de verificación de la instalación; Interfaz de comunicación
  • Page 28 – Diagrama de cableado en paralelo; Conexión eléctrica; Lista de verificación de la conexión
  • Page 29 – Operación de un no-break; • Modos de operación
  • Page 30 – Procedimiento de arranque
  • Page 31 – Procedimiento de apagado; Procedimiento manual de bypass para mantenimiento
  • Page 32 – Modos de operación
  • Page 37 – Navegación en pantalla LCD; MODO NORMAL
  • Page 38 – Submenú “Configuración de parámetros”; SÍ
  • Page 39 – Submenú “Control del sistema”
  • Page 40 – Submenú “Otra información”
  • Page 41 – Comunicaciones; Contactos secos; EPO
  • Page 42 – Alimentación Ethernet; CONTACTO DEL GENERADOR; TARJETA SNMP
  • Page 43 – Puertos paralelos de comunicación del no-break:; RESISTOR TERMINAL PARA RS-485
  • Page 45 – -Phase UPS Specifications; Español; Floor Weight Loading Table
  • Page 46 – Input
  • Page 47 – Output
  • Page 51 – Tabla de carga de peso del piso; Calibre recomendado de cables; Especificaciones de torque
  • Page 52 – Entrada; Diagramas de cableado de terminales
Loading the manual

Owner’s Manual

SmartOnline

3-Phase (50kVA & Above)

Intelligent True On-Line UPS Systems

Input/Output:
3Ø, 4 Wire (plus ground), wye

• “PM” models: 277/480V AC

• “INTPM” models: 220/380V, 230/400V or 240/415V AC (user-selectable)*

There are two separate UPS system modules: a power module and a battery module. The power module is described in this
manual and the

3-Phase UPS Specifications Addendum—50kVA & Above

. The battery module is described in a separate manual.

Important Safety Warnings

2

Power Module Features

3

Installation

5

Electrical Connection

6

Single UPS Operation

7

Multiple UPS Operation (Parallel)

10

LCD Display Navigation

15

Communications

19

Service

22

Warranty

22

Español

23

1111 W. 35th Street • Chicago, IL 60609 USA

(773) 869-1234 • www.tripplite.com

Copyright © 2007 Tripp Lite. All rights reserved. SmartOnline™ is a trademark of Tripp Lite.

* See “Parameter Setting” Sub-Menu on page 16 to set the inverter output voltage. ** CE certification applies to “INTPM” models only.

Not suitable for mobile applications.

**

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Important Safety Warnings; UPS Location Warnings; UPS Connection Warnings; Equipment Connection Warnings; Important

2 Important Safety Warnings SAVE THESE INSTRUCTIONS. This manual contains important instructions and warnings that should be followed during the installation and maintenance of all Tripp Lite SmartOnline 3-Phase UPS Systems (50kVA and above) and their batteries. All UPS connection and maintenance mu...

Page 3 - Control Panel

3 Important Safety Warnings (continued) • Connect only Tripp Lite battery modules to the UPS's external battery hardware terminals. • Do not operate the UPS without batteries. • Fuses should be replaced only by factory authorized personnel. Blown fuses should be replaced only with fuses of the same ...

Page 4 - Breakers, Switches and Fuses; Front Panel, Door Open

4 Breakers, Switches and Fuses Rectifier Input Breaker: This breaker controls input power to the UPS during normal operation. Reserve Input Breaker: This breaker controls input power to the UPS when operating from reserve power. Manual Bypass Breaker: This breaker controls input power to the UPS dur...

Other Tripp Lite Models