- Page 2 – Earth Ground Installation; Step 1 –; ) solid copper wire near the top of the; Step 3 –; ) solid copper wire and test again. If the; Figure 2
- Page 3 – Power Source Installation; for the appropriate type of; Figure 3
- Page 4 – Station Decoder Installation; make and model is the Paige Irrigation Wire, Spec P7351D.
- Page 5 – Figure 4
- Page 6 – Grounding Communication Cable; Figure 5
- Page 7 – Figure 6
Specifications:
• Controls up to 200 stations for the
Stand-Alone model
• Input power supply
100 VAC, 50/60Hz
120 VAC, 50/60Hz
240 VAC, 50/60Hz
• TDC output voltage: 40 VAC max.
• TDC output power: 98VA max.
• Storage temperature: - 3 0 C – 6 0 C
• Operating temperature: 0 – 6 0 C
• Cabinet Type: Non-corrosive, lockable wall mount,
indoor/outdoor installation
• Six 25.4mm conduit openings and one 38mm conduit opening
Cabinet Installation
Selecting the proper installation site for the 2-wire decoder is essential to safe
and reliable operation. The 2-wire decoder features a weather resistant cabinet designed for indoor or outdoor installation.
The TDC should be installed on a vertical wall or other sturdy structure near
a grounded power source. Select a location that shades the controller during the
hottest hours of the day and provides as much protection from direct sunlight,
rain, wind and snow as possible. DO NOT mount the controller where it is
exposed to direct spray from the irrigation system.
For easy operation and better view of the display (Stand-alone model),
install the TDC so that the display is at or slightly below eye level.
Step 1 –
Drill two pilot holes 15.25cm apart for the top keyholes of the
controller cabinet.
Step 2 –
Install the top screws leaving approximately 5–6mm of exposed
screw to accommodate
the cabinet.
If mounting the cabinet on dry wall or
masonry, install the appropriate type of screw
anchors or fasteners to ensure secure installation.
Step 3 –
Hang the cabinet using the top keyhole slots.
See
Figure 1
.
Step 4 –
Open the cabinet door and install the bottom two
screws to
secure the cabinet.
TDC 100/200 Stand-Alone Model
Installation Instructions
Figure 1
15.25cm
23.175cm
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Earth Ground Installation IMPORTANT! The TDC surge protection components cannot properly function unless an efficient pathway to earth ground is provided. The ground path must be as direct as possible, without sharp bends and must not exceed 30 Ohm resistance (when measured with an earth ground resi...
Power Source Installation Step 1 – Turn off the power at the power source location andplace the controller’s power switch to OFF. Connect androute the appropriate size 3-conductor cable (10 AWG[2.5mm 2 ] maximum) from the power source to the controller cabinet. The provided power cable access hole c...
Station Decoder Installation The station decoder module is available in 1-station, 2-station or 4-station configuration. The decoder modules are installed intothe TDC output board terminals. The stand-alone TDC model can handle up to 100 stations per output board. These stations can be connected to ...