Titan 773-400 - Manual
Titan 773-400 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Owner’s Manual
For professional use only
ProFinish C-100 Gun
Model Number 773-400
Parts List
Item
Part #
Description
Quantity
101
773-003
Retaining Ring .......................1
102
773-960
Air Cap “OA”..........................1
103
773-132
Spring Plate ...........................1
104
773-168
Air Cup Spring .......................1
105
773-128
Fluid Nozzle “.051” ................1
108
490-112
Fluid Fitting ............................1
109
773-170
Head ......................................1
110
580-018
Pivot Pin ................................1
111
580-019
Pivot Screw ...........................1
112
770-179
Plug .......................................1
113
773-005
Packing..................................1
114
773-095
Retainer .................................1
115
773-033
Trigger ...................................1
116
773-031
Stem Gland ...........................1
117
773-023
Air Supply Tube.....................1
118
773-167
Handle ...................................1
119
773-026
Pipe Adapter .........................1
120
773-027
Trigger Stem .........................1
121
773-029
Trigger Valve .........................1
122
773-028
Retaining Clip ........................1
123
773-021
Trigger Spring .......................1
124
773-020
Spring Bushing ......................1
125
773-016
Fluid Housing ........................1
126
773-148
Needle Assembly ..................1
127
773-019
Needle Spring .......................1
128
773-017
Adjusting Knob ......................1
129
773-067
Air Valve ................................1
130
761-722
O-Ring ...................................1
131
773-068
Air Valve Housing..................1
313-1078 Label - Fan Adjustment .........1
133
773-153
Needle, Nozzle Set ...............1
134
227-006
Adapter, 1/4”NPTx1/4”NPS ...1
773134
HVLP TOOL (not shown) ......1
773-135
Brush (not shown) .................1
Safety Precautions
Do not use equipment before reading this
section
Never operate this unit unless it is properly
grounded. A fire or explosion hazard is
present when spraying flammable materials.
Please read and understand the following
steps to assure safe operation of your sprayer.
1. Always keep spray area well ventilated.
Always keep the compressor a minimum of
20 feet from spray activity.
2. Always follow the coating or solvent
manufacturer’s safety precautions and
warnings.
3. Never spray flammable materials near
open flames, pilot lights or any other
source of ignition.
4. Always wear spray masks and protective
eye wear while spraying.
5. Never alter or modify any part of this
equipment; doing so could cause it to
malfunction.
6. Never attempt to service or disassemble
the compressor while it is plugged in.
7. Never attempt to clean the exterior of the
compressor while plugged in. CAUTION:
TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT EXPOSE TO RAIN –
STORE INDOORS
8. Never point the spray gun at anyone or
any part of the body.
9. Never leave equipment unattended. Keep
away from children or anyone not familiar
with the operation of spray equipment.
10. Never remove lid of pressure pot without
relieving pressure first.
11. Never exceed 50 psi in pressure pot.
12. Do not use halogenated hydrocarbons in
Titan equipment.
Startup Procedures
Prepare the Paint
1. Prepare the material to be sprayed
according to paint manufacturers
recommendations.
2. Strain the paint before each use. 770-119
Cone Strainer provided.
3. Thin the material to be sprayed with the
recommended solvent. Most materials
need to be thinned to obtain spraying
consistency. To achieve the proper
viscosity for spraying, either a viscosity
cup can be used or trial and error.
4. If a viscosity cup is not available, thin the
materials to a point where you will achieve
a one second interval between drops after
a paint stick has been inserted and
removed from paint.
Gun and Compressor Set-Up
1. With the compressor switch in the off
position, plug into a grounded outlet at
least 20 feet from spray activity.
2. Attach air atomizing hose to compressor.
3. Attach one end of the fluid hose to the gun
and the other end to the pressure pot.
Attach the air hose to the bottom of the
gun. Make sure that everything is secure
before spraying.
Spray Gun Adjustments
The “ProFinish” gun comes equipped with a
.051 fluid nozzle and needle and our “#0A”
medium air cap. Always test your spray pattern
on a test surface before you begin to work.
1. Fan size adjustment is controlled by
turning air cap retainer ring. Clockwise will
increase fan width, counterclockwise will
decrease fan width.
2. Top knob controls the air volume.
Clockwise will decrease air flow.
3. A round, horizontal or vertical fan pattern
can be achieved by rotating air cap as
shown by the diagrams below.
4. A round pattern will require less material
flow than a wide pattern. Lower knob
clockwise will decrease fluid flow; counter-
clockwise will increase fluid flow.
Fluid Nozzle / Needle / Air Cap
Selection
If after all of the appropriate adjustments are
made poor results are obtained, it may be
necessary to change to a different fluid nozzle /
needle or air cap. Refer to our selection chart to
match the appropriate components to the
material being sprayed.
1. To change fluid nozzle and tip remove air
cap (102) and retainer ring (101).
2. Squeeze trigger and with a wrench remove
fluid tip (105). (Use Fluid Tip Tool 773-
134, supplied, not shown)
3. Remove Adjustment Knob (128). Remove
Spring (127) and Needle (126)D.
Reassemble in reverse order 1 thru 3.
NOTE: Never use lubricants containing
silicones. Silicones will adversely
affect spray finishes and is difficult
to remove once on equipment.
NOTE: The smaller the nozzle size the
greater atomization.
WARNING
Form No. 313-1564, REV A © 2000 Titan Tool Inc. All rights reserved.
1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Titan
- Model
- 773-400
- Document type
- Manual
- Language(s)
- English
- Pages
- 2
- File size
- 182.6 KB
- Format