State Water Heaters STC-077 - Manual

State Water Heaters STC-077

State Water Heaters STC-077 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
Page: / 46

Table of Contents:

  • Page 2 – SUF Service Handbook; TABLE OF CONTENTS
  • Page 3 – INTRODUCTION
  • Page 4 – INSTALLATION; CLEARANCES
  • Page 5 – VENTING; Equivalent Feet of Pipe Intake or Exhaust; WHEN THE UNIT IS TO
  • Page 7 – CONCENTRIC VENT TERMINATION; in. is lengthened or shortened; Vertical Installation
  • Page 8 – VENTING CLEARANCES
  • Page 9 – EXTERIOR SIDEWALL CLEARANCES; DO NOT TERMINATE THE VENTING WHERE NOISE FROM THE EX-
  • Page 10 – AIR REQUIREMENTS; MINIMUM AIR FOR COMBUSTION
  • Page 11 – Direct Communication
  • Page 12 – Horizontal Ducts
  • Page 13 – CONTAMINATED AIR; does not; eliminate the need to remove flammable or corrosives from the; RUST
  • Page 14 – MULTIPLE UNIT — WATER PIPING
  • Page 15 – CONDENSATION; The “Corrosion Resistance of Cast
  • Page 16 – OPERATION; SEQUENCE OF OPERATION
  • Page 17 – CONTROLS; During Call for Heat
  • Page 18 – CIRCUT BOARDS; DISPLAY CIRCUIT BOARD
  • Page 19 – TROUBLESHOOTING; CHECK FOR 120 VAC TO CONTROL BOARD CN1 TERMINAL.; 20 VAC TO CONTROL BOARD; • Insure 120 VAC power supply has correct polarity — check neutral
  • Page 20 – TRANSFORMER; CHECK FOR 120 VAC TO TRANSFORMER FROM PIN 1 AND 2 ON CONTROL; 20 VAC TO TRANSFORMER
  • Page 21 – CHECK FOR 24 VAC AT TRANSFORMER CN4 PLUG ON CONTROL BOARD.; 4 VAC FROM TRANSFORMER
  • Page 22 – ECO CHECK; CHECK FOR 24 VAC BETWEEN PIN 4 ON CONTROL BOARD TERMINAL CN3 AND
  • Page 23 – CHECK FOR 24 VAC BETWEEN PIN 1 ON CN3 PLUG AND GROUND.; 4 VAC FROM ECO
  • Page 24 – TEMPERATURE PROBE; CHECK RESISTANCE OF THERMISTOR IN UPPER AND LOWER TEMPERATURE; TEMPERATURE PROBE RESISTANCE; PROBE PLUG
  • Page 25 – PRESSURE SWITCH CONTINUITY; CHECK FOR CONTINUITY BETWEEN PRESSURE SWITCH TERMINALS WITH; PRESSURE SWITCH CONTINUITY TEST
  • Page 26 – BLOWER; CHECK FOR 120 VAC TO BLOWER FROM CN2 PLUG PIN 1 AND 2.
  • Page 27 – PRESSURE SWITCH PERFORMANCE; CHECK PRESSURE AT SENSING PORTS ON BURNER, BLOWER INLET AND GAS; AMBIENT ROOM AIR PRESSURE; STEP 9A; TAKE AIR AND GAS PRESSURE READINGS.
  • Page 28 – STEP 9B; PRESSURE SWITCH CONTINUITY TEST — OPERATIONAL
  • Page 29 – CHECK FOR 120 VAC TO IGNITOR FROM PIN 1 AND 2 ON CONTROL BOARD
  • Page 30 – IGNITOR RESISTANCE; CHECK RESISTANCE BETWEEN TWO WIRE CONNECTS AT CN5 IGNITOR PLUG; IGNITOR RESISTANCE CHECK
  • Page 31 – GAS VALVE TEST; CHECK FOR 24 VAC TO GAS VALVE DURING TRIAL FOR IGNITION.; 4 VAC TO GAS VALVE
  • Page 32 – GAS PRESSURE CHECK; CHECK AND ADJUST SUPPLY GAS PRESSURE.; SUPPLY GAS PRESSURE TEST; MANIFOLD GAS PRESSURE TEST; Propane
  • Page 33 – COMPONENT INFORMATION; ORIFICE TABLE
  • Page 34 – PRESSURE SWTCHES
  • Page 36 – WIRING DIAGRAMS
  • Page 37 – SERVICE AIDS
  • Page 38 – SUF MUFFLER; minimum; of 8” from top of condensate elbow.
  • Page 39 – QUESTIONS AND ANSWERS; Q. How much electrical power is required for a SUF water heater?; A. Many variables affect the lime build up process including:; Q. What effect will lime build-up have on the SUF water heater?; A. When large gouges or pits appear in the anodes, replace them.; Q. How often should the anodes be inspected?
  • Page 40 – ERROR CODES
  • Page 41 – SERVICE CHECKLIST
  • Page 42 – STATE WATER HEATERS
  • Page 43 – ULTRA FORCE SUF MODELS REPLACEMENT PARTS
  • Page 44 – ULTRA FORCE SUF CONTROLS PARTS LIST
  • Page 46 – DIE; COMMERCIAL; COMMERCIAL; COMMERCIAL
Loading the manual

THIS PRINTOUT IS FOR REFERENCE ONLY!

Do not use this printout for color match or critical dimensions.

PRINTOUT MADE AT 100% OF FINAL SIZE.

THIS FILE HAS NOT BEEN TRAPPED.

This file was created with Adobe

Illustrator 8.0.1

.

DO NOT try to open this file with earlier versions.

Marketing Support Inc. assumes no responsibility for final print
quality and will not be held liable for errors or omissions due to

alterations made to this document by client, film or print vendor.

MSI requires a Chromalin or color key type proof for final approval.

If you have any questions about this file,

or require further assistance, contact MSI at 312-565-0044.

C

M

Y

K

DIE

Job #:

SWHM 104729

File Name:

104729_SrvcBk_UltraForc.ai

Size:

8.5” wide x 11” high

ProLeader:

Nichole

Updates:

jpc7.16.04tyr, NF 8.12.04

8 1/2”

11”

� � � � � � � � � � � � � �

� � � � � � �� � � � �
� � � � � � �� � � � �
� � � � � � �� � � � �

The Expert’s Choice®

COMMERCIAL

The Expert’s Choice®

COMMERCIAL

The Expert’s Choice®

COMMERCIAL

� � � � � � � �� ��� � � �� � �� � �� � � �� � �

� ��� �� � � �� � � � � � ��� ���� �� � � � �� � � �

� �� � �� � � �� �� � � �� � ��� � � �� �

� � � � �� � � � � � �� � � � � � �

� � � �� �� � �� � � � ��� �� � � �� �� �� ��� �� � � �

� �� �� �� � �� � �� � � �� � �

� � � �� �� � � � ��� � �� � � �
� � � �� � � �� ��� ��� � �� � � � �
� � � � � � � � � � � �
� � � �� �� �� � � �� �� � � �� �� �� !

� � � � �� � �� � � � � � � �

� ��� � � � � � � �

� �� � ��� � �� � � � �� � ��� �� �� ��

� �� � � �� � �� � ��� � �� �� �� �� � �� ��� � � �� �� �� �� �� �� � �� � � � ��� � � ��

� � ��� � � ���� � � ���� � � � �� � ���� �� �� � ��� � �� � ���� � � � � ! � � ! " " �

� �� �� �� � �� � �� � � �� � �

� � � �� �� � � � ��� � �� � � �

� � � �� � � �� ��� ��� � �� � � � �

� � � � � � � � � � � �

� � � �� �� �� � � �� �� � � �� �� �� !

� �� � � �� � �� � ��� � �� �� �� �� � �� ��� � � �� �� �� �� �� �� � �� � � � ��� � � ��

� � ��� � � ���� � � ���� � � � �� � ���� �� �� � ��� � �� � ���� � � � � ! � � ! " " �

� � � � � ��� � ��� � � � �� �� �� ��� � � � ���� � ���� � �

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SUF Service Handbook; TABLE OF CONTENTS

SUF Service Handbook TABLE OF CONTENTS S T C - 0 7 7 Introduction . . . . . . . . . . . . . . . . . . . 2 Installation Clearances . . . . . . . . . . . . . . . . . . . . . 3Gas Requirements . . . . . . . . . . . . . . . 3Venting . . . . . . . . . . . . . . . . . . . . . 4 – 8Air Requirements . . . ....

Page 3 - INTRODUCTION

S U F S E R V I C E H A N D B O O K I N T R O D U C T I O N Technical Training Department State Water Heaters STC-077 2 Ashland City, Tennessee © 2004 INTRODUCTION This service handbook is designed to aid in servicing and troubleshooting State SUF 150, 199 and 240 water heaters. No duplication or re...

Page 4 - INSTALLATION; CLEARANCES

S U F S E R V I C E H A N D B O O K I N S T A L L A T I O N State Water Heaters Technical Training Department Ashland City, Tennessee © 2004 3 STC-077 INSTALLATION CLEARANCES This portion of the handbook will review often overlooked installation require-ments. The installation manual covers these it...

Other State Water Heaters Models

All State Water Heaters Other