Slant/Fin VHS-30 - Manual

Slant/Fin VHS-30

Slant/Fin VHS-30 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
Page: / 27

Table of Contents:

  • Page 2 – ICTORY; II; VHS Models; Natural
  • Page 6 – ProTech FasNSeal System
  • Page 7 – Figure 6
  • Page 11 – Natural Draft Chimney and Type “B” Venting Tables
  • Page 14 – GAS PIPING; DANGER; Thermostat Connections
  • Page 15 – Victory; Air Control System
  • Page 17 – Figure 15. Piping Arrangement
  • Page 18 – Boiler Water Content
  • Page 20 – Boiler rated input in; Gas Rate Table
  • Page 21 – If the boiler is vented horizontally through the wall,
  • Page 24 – General Troubleshooting Guide For Servicepeople
  • Page 25 – IF REPLACEMENT PARTS ARE NEEDED; replacement
  • Page 26 – III
Loading the manual

HOT WATER MODELS VHS-30 THROUGH VHS-180

GAS-FIRED CAST-IRON BOILERS FOR NATURAL AND L.P. PROPANE GASES

IMPORTANT

READ ALL OF THE FOLLOWING

WARNINGS AND STATEMENTS

BEFORE READING THE

INSTALLATION INSTRUCTIONS

WARNING

LIQUEFIED PETROLEUM (L.P.)

PROPANE GAS-FIRED BOILERS

Installation location ONLY as permitted in paragraph
entitled "LIQUEFIED PETROLEUM (L.P.) PROPANE
GAS-FIRED BOILER LOCATION" on page 3 of this
instruction book.
The above warning does not apply to

NATURAL

gas-

fired boilers.

The installation must conform to the requirements of
the authority having jurisdiction or, in the absence of
such requirements, to the National Fuel Gas Code,
ANSI Z223.1-latest edition. The installation must also
conform to the additional requirements in this Slant/Fin
Instruction Book.

In addition where required by the authority having juris-
diction, the installation must conform to American
Society of Mechanical Engineers Safety Code for
Controls and Safety Devices for Automatically Fired
Boilers, No. CSD-1.

WARNING

This boiler, gas piping and accessories must be
installed, connected, serviced and repaired by a
trained, experienced service technician, familiar with all
precautions required for gas-fired equipment and
licensed or otherwise qualified, in compliance with the
authority having jurisdiction.

WARNING

The venting system of this boiler is under positive pres-
sure when it is connected to the outdoors with 3" diameter
pipe. Leakage from this system can be hazardous and if
not avoided can result in death or serious injury. In addi-
tion to the recommendations within this manual and the
User’s Information Manual, the venting system, from the
blower to the outdoor discharge, must be carefully
checked annually by a qualified service agency.

This manual must be left with owner and
should be hung on or adjacent to the boiler
for reference.

V

ICTORY

II

Models with Intermittent Pilot System – Spark Ignition

INSTALLATION AND OPERATING INSTRUCTIONS

Publication No. VHS-40 Part No. 44-0831 Printed in U.S.A.404

Heating Contractor

Address

Phone Number

Boiler Model Number

Boiler Serial Number

Installation Date

Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page

Dimensions, Rating and Orifice Sizes . . . . . . . . . . . . . . . . . . .2
Installation Requirements:

Boiler Location and Foundation . . . . . . . . . . . . . . . . . . . . .3
Minimum Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Boiler Room Air Supply and Ventilation . . . . . . . . . . . . . . .4

Flue Gas Venting Requirements . . . . . . . . . . . . . . . . . . . . . . .4
Category

II

and

III

Venting:

Venting Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Flue Length Restriction . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Category

I

Venting:

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Vent Connector Material . . . . . . . . . . . . . . . . . . . . . . . . . .10
Venting Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Venting System Regular Inspection . . . . . . . . . . . . . . . . . . . .14
Gas Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Electrical Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Water Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Piping a Heating-Cooling System . . . . . . . . . . . . . . . . . . . . .18
Operating Instructions:

Filling and Venting Water Systems . . . . . . . . . . . . . . . . . .18
Initial Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Operating Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Burner Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Safety Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Sequence of Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
General Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . .24
Appendix A and B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ICTORY; II; VHS Models; Natural

V ICTORY II VHS Models NOTE: Height dimensions increase by 1 3 ⁄ 4 " and depth increases to 22 1 ⁄ 4 " when combustible floor kit is used. Natural #49 50 50 50 51 51 51 52 52 52 Propane #57 58 59 59 60 60 61 62 63 63 VHS-30 30,000 2 8 1 ⁄ 8 " 14 5 ⁄ 8 " 190 VHS-60 60,000 3 11 1 ⁄ 8 &...

Page 6 - ProTech FasNSeal System

V ICTORY II VHS Models Heat-Fab Saf-T Vent System BoilerModel No. MinimumLength, Ft. 0 to5500 Ft.Altitudes 5500 to7000 Ft.Altitudes 7000 to10,000 Ft.Altitudes EquivalentLength ofeach 90°Elbow, Ft. Max. Equivalent Length (Ft.) VHS-30, 40 40 40 3 2 60, 90and 120 VHS-150 40 40 20 3 2 VHS-180 40 20 20 3...

Page 7 - Figure 6

V ICTORY II VHS Models Figure 6 Figure 5 VICTORY II HORIZONTAL (SIDEWALL) VENTING All joints must be liquid and pressure tight. Use U/L listed single wall 3" dia. AL29-4C* S.S. venting materials * Definition of Snow Line: Knowledge of local conditions will reveal the maximum height that repeated...

Other Slant/Fin Models

All Slant/Fin Other