RATINGS CHART – GAS BOILERS

©Slant/Fin Corp. 2007

SLANT/FIN CORPORATION, Greenvale, NY 11548 • Phone: (516) 484-2600

FAX: (516) 484-5921 •

In Canada: Slant/Fin LTD/LTEE, Mississauga, Ontario

www.slantfin.com

BOBCAT

Modulating, Condensing - High Efficiency

SPECIFICATIONS:

B-120 Boiler

B-200 Boiler

Fuel Rate Input:

120,000 BTUH max

30,000 BTUH min

200,000 BTUH max

50,000 BTUH min

Boiler Water Volume:

1.0 gallon (8.3 lbs)

1.4 gallon (11.07 lbs)

Water Piping

Connections:

1” NPT (male)

Weight of Boiler

(uncrated):

145 lbs.

200 lbs.

Gas orifice size:

Natural Gas - No orifice used*

Propane - .2025” inside

diameter

**

Propane - .250” inside

diameter

**

Gas Piping Connection:

1/2” NPT (female)

Vent Connection:

3” nominal I.D. pipe (PVC, CPVC or stainless steel)

Air Intake Connection:

3” nominal I.D. pipe (PVC, CPVC or stainless steel)

*Note

: No orifice changes are required for high altitude installations.