Siemens X-400 - User Manual

Siemens X-400

Siemens X-400 – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
81 Page 81
82 Page 82
83 Page 83
84 Page 84
85 Page 85
86 Page 86
87 Page 87
88 Page 88
89 Page 89
90 Page 90
91 Page 91
92 Page 92
93 Page 93
94 Page 94
95 Page 95
96 Page 96
97 Page 97
98 Page 98
99 Page 99
100 Page 100
101 Page 101
102 Page 102
103 Page 103
104 Page 104
105 Page 105
106 Page 106
107 Page 107
108 Page 108
109 Page 109
110 Page 110
111 Page 111
112 Page 112
113 Page 113
114 Page 114
115 Page 115
116 Page 116
117 Page 117
118 Page 118
119 Page 119
120 Page 120
121 Page 121
122 Page 122
123 Page 123
124 Page 124
125 Page 125
126 Page 126
127 Page 127
128 Page 128
129 Page 129
130 Page 130
131 Page 131
132 Page 132
133 Page 133
134 Page 134
135 Page 135
136 Page 136
137 Page 137
138 Page 138
139 Page 139
140 Page 140
141 Page 141
142 Page 142
143 Page 143
144 Page 144
145 Page 145
146 Page 146
147 Page 147
148 Page 148
Page: / 148

Table of Contents:

  • Page 2 – Classification of Safety-Related Notices; indicates that death or severe personal injury
  • Page 3 – RM; Notice; OFF; Notice
  • Page 4 – Personnel Qualification Requirements; ment in accordance with current standards in safety technology; Correct Usage of Hardware Products; Caution
  • Page 5 – Correct Usage of Software Products
  • Page 7 – Preface; Purpose of the Operating Instructions; SCALANCE X-400 Configuration Manual; Validity of the Operating Instructions; Industrial Ethernet Switches SCALANCE X414-3E
  • Page 8 – Further Documentation; Standards and Approvals
  • Page 9 – Contents
  • Page 11 – Information; Switching; Essentially, switches have the following functions:; Connection of Collision Domains / Subnets
  • Page 12 – Introduction to Industrial Ethernet Switches; The Need for Industrial Ethernet Switches; You can use a SCALANCE X-400 in the following network topologies:
  • Page 13 – Functional Description
  • Page 14 – Electrical Ring; Slot 5
  • Page 15 – Configuration Example
  • Page 16 – Structure
  • Page 19 – Redundant Linking of Network Segments
  • Page 21 – System Description of SCALANCE X-400; Gigabit technology
  • Page 23 – Components of SCALANCE X-400; Component Function
  • Page 24 – Ports of SCALANCE X-400; Transmission Rate
  • Page 25 – Transmission medium; The maximum transmission distance (segment length) is 100 m.; Connectors
  • Page 26 – Transmission Range
  • Page 27 – Two FOC types can be used:
  • Page 28 – 00Base-FX module and multimode GFOC: 3 km; BFOC connectors are used.
  • Page 29 – The transmission rate of the optical gigabit ports is 1 Gbps.; Transmission Mode; Data is transmitted over multimode FOC. The wavelength is 850 nm.; SC duplex female connectors are used.
  • Page 30 – Data is transmitted over single mode FOC. The wavelength is 1310 nm.
  • Page 31 – Compatibility of SCALANCE X-400; Compatibility List; End devices; Redundant linking of 100 Mbps networks over FO cable.; Note
  • Page 33 – Product Description of SCALANCE X-400; SCALANCE X414-3E Basic Device; Overview
  • Page 35 – Components of the Product; The following components are supplied with the SCALANCE X414-3E:
  • Page 36 – Spares; 0 sheets of labels (A4) each with 15 labeling strips; Slots; Power Mod
  • Page 39 – Module
  • Page 40 – Signaling Contact; The following can be signaled over a floating signaling contact:; Failure of the power supply.; The power supply monitored is selected in the fault mask.; Bad link status of a port.
  • Page 41 – Inputs; DI Module; It is also possible to read the statuses over SNMP.
  • Page 42 – CPU
  • Page 43 – Serial Port; Ethernet Port; ual
  • Page 44 – Area of Application; How It Works; ACCEPTED
  • Page 45 – Diagnostics
  • Page 46 – Startup Behavior; Startup
  • Page 49 – Modules; Available Module Types; Procedure Cabling Connec-
  • Page 50 – Options for Slot 5
  • Page 51 – The connectors are 2x2 BFOC sockets.; LED Display of the Fast Ethernet Media Module; In display mode A, the current connection status is displayed.
  • Page 53 – LED Display of the Gigabit Media Module
  • Page 55 – Slots of the Covers; Available Cover Types
  • Page 56 – Displays of the Cover
  • Page 57 – The LEDs of the CV490 2x100 cover have no function.
  • Page 59 – Cover; Slot of the Dummy Cover; Displays of the Dummy Cover
  • Page 61 – Extender Modules; Twisted Pair Extender EM495-8; Eight Additional 100Base-TX Ports
  • Page 62 – Covers
  • Page 63 – Media Module Extender EM496-4; Four Additional Slots for Media Modules; Connector
  • Page 67 – Installation and Commissioning; Installing / Removing the SCALANCE X414-3E; Warning; Power supply by a SELV power source (according to IEC 60950) or PELV
  • Page 68 – Installing on an S7-300 Rail; To install the device, follow the steps below:
  • Page 69 – Removing from the S7-300 rail; To remove the device, follow the steps below:
  • Page 70 – Installation on a 35 mm Standard Rail
  • Page 71 – Removing from the 35 mm Standard Rail
  • Page 72 – Installing a Media Module; middle section of the media module is heard to click into place.
  • Page 73 – Removing a Media Module; with a slotted screwdriver with a 2.8 mm wide blade.
  • Page 74 – Variants of the Covers
  • Page 75 – Fitting a Dummy Cover
  • Page 76 – Installing / Removing Extender Modules; Installing the Twisted Pair Extender on the S7-300 Rail; You require the following tools:; Remove the cover from slot 11 of the basic device.; Remove the two covers from the extender.
  • Page 78 – Removing the Twisted Pair Extender from the S7-300 Rail
  • Page 79 – Installing the Twisted Pair Extender on the 35 mm Standard Rail; visible from the rear of the frame.
  • Page 81 – Removing the Twisted Pair Extender from the 35 mm Standard Rail
  • Page 82 – Installing the Media Module Extender on the S7-300 Rail; Remove the four covers from the extender.
  • Page 84 – Removing the Media Module Extender from the S7-300 Standard Rail
  • Page 85 – Installing the Media Module Extender on the 35 mm Standard Rail
  • Page 87 – Removing the Media Module Extender from the 35 mm Standard Rail
  • Page 88 – Slot Numbers of the Modules and Covers; Specifying the Slot Number; Place the required slot number in front of the module.
  • Page 89 – Defaults; DIL Switches; STBY; Further Device Properties
  • Page 90 – Polarity Reversal Protection X1, X2; + 24 V power supply 1
  • Page 92 – Digital input 1
  • Page 93 – Digital input 5
  • Page 94 – Connectors for the Twisted Pair Cables; The FastConnect Cabling System
  • Page 95 – Connecting TP Cord to FC Cable; IE FC RJ-45 modular outlet insert 1GE
  • Page 98 – Removing the FC Cable from SCALANCE X414-3E
  • Page 99 – Gigabit Transmission with FOC
  • Page 100 – Fast Ethernet Transfer with FOC
  • Page 101 – Controls; Switches
  • Page 102 – ON; Switch Status
  • Page 103 – Ring Ports in Slots 5 to 7
  • Page 104 – Possible Settings of the Ring Ports
  • Page 105 – Changing the display modes
  • Page 106 – Display; Power Module
  • Page 107 – Behavior; LED on; Fault occurred
  • Page 109 – Display Modes A through C; Label Color
  • Page 110 – Display in Display Mode D
  • Page 111 – LED Display of the Digital Inputs 1 through 8
  • Page 112 – Display Modes A through D
  • Page 113 – Port Statuses in DMode A; Port Color Status
  • Page 114 – Port Statuses in DMode B
  • Page 115 – Port Statuses in DMode C; off
  • Page 116 – Port Statuses in DMode D; In display mode D, you can see whether or not the port is monitored.
  • Page 117 – Replacing the C-PLUG; Inserting the C-PLUG in the Slot
  • Page 118 – Location; Determining the Location of a SCALANCE X-400; With the PST Tool V3.0, you can trigger this function with
  • Page 119 – Technical Specifications; Interfaces
  • Page 121 – Permitted Environmental Conditions; MTBF information (mean time between failure); Device
  • Page 131 – Approvals, Certificates; CE Marking; Voltage Limits” (Low Voltage Equipment Directive)
  • Page 132 – EMC Directive; The products are designed for use in an industrial environment:; Requirements; Industry; Explosion Protection Directive; II 3 G EEx nA II T3...T6; Required FDA and IEC labels; The listed media modules meet the FDA and IEC requirements.; F D A; C L A S S 1 L A S E R P R O D U C T; FDA and IEC labels are not required for media module MM491-2.
  • Page 133 – Directive on Machines
  • Page 134 – Note for Australia; Underwriters Laboratories (UL) complying with Standard UL 60950-1; UL Approval Industrial Control Equipment; Underwriters Laboratories (UL) complying with Standard UL 508; CSA Approval Information Technology Equipment
  • Page 135 – cULus Approval Information Technology Equipment; cULus Approval Industrial Control Equipment; Underwriters Laboratories Inc. complying with; cULus Approval Hazardous Location; Underwriters Laboratories Inc. complying with
  • Page 136 – FM Approval; The product complies with the requirements of the standards; ATEX Approval; The product complies with the requirements of the standard
  • Page 137 – Certification
  • Page 139 – Glossary
  • Page 143 – Store and forward; Virtual LAN within a physically existing network.
  • Page 145 – Index; Fast Ethernet media module MM491-
  • Page 147 – A&D Technical Support
  • Page 148 – Service & Support on the Internet; where you will find the following:
Loading the manual

SIMATIC NET

Operating Instructions for
SCALANCE X-400
Industrial Ethernet Switches

Preface, Contents

Introduction to
Industrial Ethernet Switches

1

System Description of
SCALANCE X-400

2

Product Description of
SCALANCE X-400

3

Media Modules, Covers,
Dummy Cover

4

Extender Modules

5

Installation and
Commissioning

6

Technical Specifications

7

Approvals, Certificates

Glossary, Index

C79000-G8976-C186-03

Release 11/2005

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Classification of Safety-Related Notices; indicates that death or severe personal injury

© Copyright Siemens AG, 1998 to 2005 - All rights reserved The reproduction, transmission or use of this document or itscontents is not permitted without express written authority.Offenders will be liable for damages. All rights, including rightscreated by patent grant or registration of a utility m...

Page 3 - RM; Notice; OFF; Notice

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 3 Trademarks SIMATIC ® , SIMATIC NET ® , SCALANCE ® and SIMATIC NET Networking for Indus- try® are registered trademarks of Siemens AG. Third parties using for their own purposes any other names in this docum...

Page 4 - Personnel Qualification Requirements; ment in accordance with current standards in safety technology; Correct Usage of Hardware Products; Caution

Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 4 C79000-G8976-C186-03 Personnel Qualification Requirements Only qualified personnel should be allowed to install and work on this equipment. Qualified personnel as referred to in this manual or in the warning notes are defined a...

Other Siemens Models