Page 2 - Classification of Safety-Related Notices; indicates that death or severe personal injury
© Copyright Siemens AG, 1998 to 2005 - All rights reserved The reproduction, transmission or use of this document or itscontents is not permitted without express written authority.Offenders will be liable for damages. All rights, including rightscreated by patent grant or registration of a utility m...
Page 3 - RM; Notice; OFF; Notice
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 3 Trademarks SIMATIC ® , SIMATIC NET ® , SCALANCE ® and SIMATIC NET Networking for Indus- try® are registered trademarks of Siemens AG. Third parties using for their own purposes any other names in this docum...
Page 4 - Personnel Qualification Requirements; ment in accordance with current standards in safety technology; Correct Usage of Hardware Products; Caution
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 4 C79000-G8976-C186-03 Personnel Qualification Requirements Only qualified personnel should be allowed to install and work on this equipment. Qualified personnel as referred to in this manual or in the warning notes are defined a...
Page 5 - Correct Usage of Software Products
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 5 Correct Usage of Software Products Please note the following regarding the correct usage of software products: Caution This software may only be used for the applications described in the catalog or the tec...
Page 7 - Preface; Purpose of the Operating Instructions; SCALANCE X-400 Configuration Manual; Validity of the Operating Instructions; Industrial Ethernet Switches SCALANCE X414-3E
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 7 Preface Purpose of the Operating Instructions These operating instructions describe the functions of the SCALANCE X-400 product line of modular Industrial Ethernet switches and support you during instal-lat...
Page 8 - Further Documentation; Standards and Approvals
Preface Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 8 C79000-G8976-C186-03 Further Documentation For help on configuration and diagnostics using Web-based management, the CLI command line, or SNMP, refer to the following documentation: ● SCALANCE X-400 Configuration Manual...
Page 9 - Contents
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 9 Contents 1 Introduction to Industrial Ethernet Switches ............................................................ 11 1.1 Basic Information ...................................................................
Page 11 - Information; Switching; Essentially, switches have the following functions:; Connection of Collision Domains / Subnets
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 11 Introduction to Industrial Ethernet Switches 1 1.1 Basic Information Switching With switching technology, data packets are forwarded directly from the input port to the appropriate output port during data ...
Page 12 - Introduction to Industrial Ethernet Switches; The Need for Industrial Ethernet Switches; You can use a SCALANCE X-400 in the following network topologies:
Introduction to Industrial Ethernet Switches Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 12 C79000-G8976-C186-03 The Need for Industrial Ethernet Switches With over 80% of LANs based on Ethernet, this is the most commonly used tech-nology. The use of switches is particular...
Page 13 - Functional Description
Introduction to Industrial Ethernet Switches Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 13 1.2 Topologies 1.2.1 Ring with Redundancy Manager To increase the availability, optical or electrical line topologies of up to 50 switches (SCALANCE X-400, SCAL...
Page 14 - Electrical Ring; Slot 5
Introduction to Industrial Ethernet Switches Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 14 C79000-G8976-C186-03 Electrical Ring A redundant electrical ring with redundancy manager can be set up without media modules since the basic device provides two RJ-45 jacks on slot ...
Page 15 - Configuration Example
Introduction to Industrial Ethernet Switches Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 15 Configuration Example Sample configurations with SCALANCE X414-3E, SIMATIC S7-200/300/400, op-erator control and monitoring system, H system and PC as end devic...
Page 16 - Structure
Introduction to Industrial Ethernet Switches Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 16 C79000-G8976-C186-03 1.2.2 Star Structure Functional Description Star structures can be implemented with the SCALANCE X414-3E. The cascading depth and total span of a network are li...
Page 19 - Redundant Linking of Network Segments
Introduction to Industrial Ethernet Switches Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 19 1.2.4 Redundant Linking of Network Segments The example of redundant linking of two network segments as shown here is pos-sible only when linking between X414 b...
Page 21 - System Description of SCALANCE X-400; Gigabit technology
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 21 System Description of SCALANCE X-400 2 2.1 Properties, Functionality and Features of SCALANCE X-400 This chapter explains special properties, features and options available to you with the SCALANCE X-400 p...
Page 23 - Components of SCALANCE X-400; Component Function
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 23 Components of SCALANCE X-400 The following table shows the components of SCALANCE X-400: Component Function Figure Basic device consisting of Backplane Power module DI ...
Page 24 - Ports of SCALANCE X-400; Transmission Rate
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 24 C79000-G8976-C186-03 2.2 Ports of SCALANCE X-400 SCALANCE X-400 provides you with electrical ports that can be used as gigabit and ring ports. The expansion with media modules provides you ...
Page 25 - Transmission medium; The maximum transmission distance (segment length) is 100 m.; Connectors
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 25 Connections to other switches can use half or full duplex; connections to hubs are possible only in half duplex mode. Transmission medium Data transmission at 10 Mbps a...
Page 26 - Transmission Range
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 26 C79000-G8976-C186-03 2.2.2 1000Base-TX Transmission Rate The transmission rate of the electrical gigabit ports is 1 Gbps. Transmission Mode The transmission mode for 1000Base-TX is specifie...
Page 27 - Two FOC types can be used:
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 27 2.2.3 100Base-FX Transmission Rate The transmission rate of the optical fast Ethernet ports is 100 Mbps. Transmission Mode Transmission with 100Base-FX is defined in th...
Page 28 - 00Base-FX module and multimode GFOC: 3 km; BFOC connectors are used.
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 28 C79000-G8976-C186-03 Transmission Range The maximum transmission range (segment length) depends on the module se-lected and the FOC. The range is as follows: ● 100Base-FX module and multimo...
Page 29 - The transmission rate of the optical gigabit ports is 1 Gbps.; Transmission Mode; Data is transmitted over multimode FOC. The wavelength is 850 nm.; SC duplex female connectors are used.
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 29 2.2.4 1000Base-SX Transmission Rate The transmission rate of the optical gigabit ports is 1 Gbps. Transmission Mode Transmission with 1000Base-FX is defined in the IEEE...
Page 30 - Data is transmitted over single mode FOC. The wavelength is 1310 nm.
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 30 C79000-G8976-C186-03 2.2.5 1000Base-LX Transmission Rate The transmission rate of the optical gigabit ports is 1 Gbps. Transmission Mode Transmission with 1000Base-LX is defined in the IEEE...
Page 31 - Compatibility of SCALANCE X-400; Compatibility List; End devices; Redundant linking of 100 Mbps networks over FO cable.; Note
System Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 31 2.3 Compatibility of SCALANCE X-400 Compatibility List The following products and devices are compatible with SCALANCE X-400: ● End devices All SIMATIC NET products wit...
Page 33 - Product Description of SCALANCE X-400; SCALANCE X414-3E Basic Device; Overview
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 33 Product Description of SCALANCE X-400 3 3.1 SCALANCE X414-3E Basic Device Overview The SCALANCE X-400 product line consists of modular Industrial Ethernet switches, media modules and extenders. 100 Mbit an...
Page 35 - Components of the Product; The following components are supplied with the SCALANCE X414-3E:
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 35 Components of the Product The following components are supplied with the SCALANCE X414-3E: ● Basic device with power module in slot 2, DI module with eight digital inp...
Page 36 - Spares; 0 sheets of labels (A4) each with 15 labeling strips; Slots; Power Mod
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 36 C79000-G8976-C186-03 Spares ● 1 C-PLUG (order number: 6GK1 900-0AB00) ● 7 covers for slots (order number: 6GK5 490-0AA00-0AA2) - 1 cover for slot 5 (1 Gbps - TP) - 2 covers for slots 6 and...
Page 39 - Module
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 39 3.1.1 Power Module The power module is inserted in slot 2. The power can be fed into the power module redundantly over two inputs. The two power inputs are isolated fr...
Page 40 - Signaling Contact; The following can be signaled over a floating signaling contact:; Failure of the power supply.; The power supply monitored is selected in the fault mask.; Bad link status of a port.
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 40 C79000-G8976-C186-03 Signaling Contact The following can be signaled over a floating signaling contact: ● Failure of the power supply. The power supply monitored is selected in the fault m...
Page 41 - Inputs; DI Module; It is also possible to read the statuses over SNMP.
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 41 3.1.2 Digital Inputs DI Module The digital input module is located in slot 3 and provides the user with eight digital inputs. The cables are connected to the bottom of...
Page 42 - CPU
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 42 C79000-G8976-C186-03 3.1.3 Switch CPU The Switch CPU is in slot 4. The CPU has four DIL switches for configuring the device. This module also has four LEDs for displaying parameter assignm...
Page 43 - Serial Port; Ethernet Port; ual
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 43 Serial Port The Switch CPU of the SCALANCE X414-3E has an RS-232 port. This is used for the following purposes: ● Firmware updates ● Management with the aid of the com...
Page 44 - Area of Application; How It Works; ACCEPTED
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 44 C79000-G8976-C186-03 3.1.4 C-PLUG (Configuration Plug) Area of Application The C-PLUG is an exchangeable medium for storage of the configuration data of the modular switch and ships with t...
Page 45 - Diagnostics
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 45 A device with an accepted C-PLUG (ACCEPTED status) inserted uses the configu-ration data of the C-PLUG automatically when it starts up. Acceptance is possible only whe...
Page 46 - Startup Behavior; Startup
Product Description of SCALANCE X-400 Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 46 C79000-G8976-C186-03 Startup Behavior C-PLUG X414-3E Startup 1 not found with internal configuration (if it exists) or with factory defaults. 2 empty with internal configuration, immediate...
Page 49 - Modules; Available Module Types; Procedure Cabling Connec-
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 49 Media Modules, Covers, Dummy Cover 4 4.1 Media Modules Available Module Types The following media modules are available to expand the basic device: ● MM491-2 (100 Mbps) order number: 6GK5 491-2AB00-8AA2 ● ...
Page 50 - Options for Slot 5
Media Modules, Covers, Dummy Cover Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 50 C79000-G8976-C186-03 Note It is possible to insert and remove the media modules during operation. Before inserting a media module, remove the cover and cap from the slot. Please put these awa...
Page 51 - The connectors are 2x2 BFOC sockets.; LED Display of the Fast Ethernet Media Module; In display mode A, the current connection status is displayed.
Media Modules, Covers, Dummy Cover Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 51 4.1.1 Fast Ethernet Media Module MM491-2 (100Base-FX) The fast Ethernet media module MM491-2 can be used optionally in slots 6 and 7 of the basic device and when using th...
Page 53 - LED Display of the Gigabit Media Module
Media Modules, Covers, Dummy Cover Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 53 4.1.3 Gigabit Media Module MM492-2 (1000Base-SX) The MM492-2 gigabit media module can be inserted as an option in slot 5. Properties The gigabit media module provides two...
Page 55 - Slots of the Covers; Available Cover Types
Media Modules, Covers, Dummy Cover Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 55 4.2 Covers, Dummy Cover 4.2.1 Covers Slots of the Covers Note The protective caps for the media module terminal strips and the covers must be fitted in all slots that do ...
Page 56 - Displays of the Cover
Media Modules, Covers, Dummy Cover Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 56 C79000-G8976-C186-03 CV490 2x1000 When using the gigabit ports for electrical cables (twisted pair), use cover type CV490 2x1000 on slot 5. F L 1L 2 R M S T B Y D M 1D M 2 P 1P 2 P 1P 2P 3P 4...
Page 57 - The LEDs of the CV490 2x100 cover have no function.
Media Modules, Covers, Dummy Cover Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 57 CV490 2x100 Slots 6 and 7 are solely for the fast Ethernet media modules MM491-2 and MM491-2LD. The basic device does not provide any ports on these slots. 2 3 4 1 1 8 9 ...
Page 59 - Cover; Slot of the Dummy Cover; Displays of the Dummy Cover
Media Modules, Covers, Dummy Cover Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 59 4.2.2 Dummy Cover Slot of the Dummy Cover The dummy cover with the name CV490 COVER is located in slot 8 of the SCALANCE X414-3E. Due to system requirements, this slot ha...
Page 61 - Extender Modules; Twisted Pair Extender EM495-8; Eight Additional 100Base-TX Ports
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 61 Extender Modules 5 5.1 Twisted Pair Extender EM495-8 Eight Additional 100Base-TX Ports The extender module for twisted pair transmission provides an additional eight ports for connecting twisted pair cable...
Page 62 - Covers
Extender Modules Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 62 C79000-G8976-C186-03 Figure 5-2 Twisted pair extender EM495-8 Covers For slots 12 and 13 of the twisted pair extenders EM495-8, you can use the cover that can be used on slots 9 through 11 on the basic device....
Page 63 - Media Module Extender EM496-4; Four Additional Slots for Media Modules; Connector
Extender Modules Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 63 5.2 Media Module Extender EM496-4 Four Additional Slots for Media Modules By adding the media module extender, the basic device is extended by four slots that you can equip with the follow...
Page 67 - Installation and Commissioning; Installing / Removing the SCALANCE X414-3E; Warning; Power supply by a SELV power source (according to IEC 60950) or PELV
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 67 Installation and Commissioning 6 6.1 Installing / Removing the SCALANCE X414-3E ! Warning SCALANCE X-400 is designed for operation with safety extra-low voltage (SELV). This means that only safety extra-lo...
Page 68 - Installing on an S7-300 Rail; To install the device, follow the steps below:
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 68 C79000-G8976-C186-03 6.1.1 Installing / Uninstalling with an S7-300 Rail Installing on an S7-300 Rail For installation, you require a slotted screwdriver with a 5.5 mm wide blade. Notice When ins...
Page 69 - Removing from the S7-300 rail; To remove the device, follow the steps below:
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 69 Figure 6-1 Installation on an S7-300 rail Removing from the S7-300 rail To remove the device, you require a slotted screwdriver with a 5.5 mm wide blade. Notice When removing...
Page 70 - Installation on a 35 mm Standard Rail
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 70 C79000-G8976-C186-03 6.1.2 Installing / Uninstalling with a 35 mm Standard Rail Installation on a 35 mm Standard Rail ! Caution If the SCALANCE X-400 is liable to severe vibration (> 10 g), us...
Page 71 - Removing from the 35 mm Standard Rail
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 71 Figure 6-2 Installation on a 35 mm standard rail Removing from the 35 mm Standard Rail Since the two captive screws in slot 7 and between slots 8 and 9 are not used to secure...
Page 72 - Installing a Media Module; middle section of the media module is heard to click into place.
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 72 C79000-G8976-C186-03 6.2 Installing / Removing the Media Modules, Covers and Dummy Cover 6.2.1 Installing / Removing a Media Module Installing a Media Module For installation, you require a slott...
Page 73 - Removing a Media Module; with a slotted screwdriver with a 2.8 mm wide blade.
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 73 Figure 6-3 Inserting a media module Removing a Media Module To remove the device, you require a slotted screwdriver with a 2.8 mm wide blade. Note Removing a fast Ethernet me...
Page 74 - Variants of the Covers
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 74 C79000-G8976-C186-03 6.2.2 Fitting / Removing the Covers Variants of the Covers There are three variants of the covers ● CV490 2x1000 1 Gbps, electrical transmission, 2 port displays possible slo...
Page 75 - Fitting a Dummy Cover
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 75 6.2.3 Fitting / Removing a Dummy Cover Fitting a Dummy Cover There is only one dummy cover (no port displays connected to the front) on slot 8. To fit a cover, you do not req...
Page 76 - Installing / Removing Extender Modules; Installing the Twisted Pair Extender on the S7-300 Rail; You require the following tools:; Remove the cover from slot 11 of the basic device.; Remove the two covers from the extender.
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 76 C79000-G8976-C186-03 6.3 Installing / Removing Extender Modules 6.3.1 Installing / Removing the Twisted Pair Extender Installing the Twisted Pair Extender on the S7-300 Rail You require the follo...
Page 78 - Removing the Twisted Pair Extender from the S7-300 Rail
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 78 C79000-G8976-C186-03 Removing the Twisted Pair Extender from the S7-300 Rail You require the following tools: ● slotted screwdriver with a 2.8 mm wide blade ● slotted screwdriver with a 5.5 mm wi...
Page 79 - Installing the Twisted Pair Extender on the 35 mm Standard Rail; visible from the rear of the frame.
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 79 Installing the Twisted Pair Extender on the 35 mm Standard Rail ! Caution If the SCALANCE X-400 with extender is liable to severe vibration (> 10 g), use the S7-300 rail f...
Page 81 - Removing the Twisted Pair Extender from the 35 mm Standard Rail
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 81 Removing the Twisted Pair Extender from the 35 mm Standard Rail To remove the device, you require a slotted screwdriver with a 2.8 mm wide blade. The captive screw in the low...
Page 82 - Installing the Media Module Extender on the S7-300 Rail; Remove the four covers from the extender.
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 82 C79000-G8976-C186-03 6.3.2 Installing / Removing the Media Module Extender Installing the Media Module Extender on the S7-300 Rail You require the following tools: ● slotted screwdriver with a 2....
Page 84 - Removing the Media Module Extender from the S7-300 Standard Rail
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 84 C79000-G8976-C186-03 Removing the Media Module Extender from the S7-300 Standard Rail You require the following tools: ● slotted screwdriver with a 2.8 mm wide blade ● slotted screwdriver with a ...
Page 85 - Installing the Media Module Extender on the 35 mm Standard Rail
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 85 Installing the Media Module Extender on the 35 mm Standard Rail ! Caution If the SCALANCE X-400 with extender is liable to severe vibration (> 10 g), use the S7-300 rail f...
Page 87 - Removing the Media Module Extender from the 35 mm Standard Rail
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 87 Removing the Media Module Extender from the 35 mm Standard Rail To remove the device, you require a slotted screwdriver with a 2.8 mm wide blade. Although the captive screw i...
Page 88 - Slot Numbers of the Modules and Covers; Specifying the Slot Number; Place the required slot number in front of the module.
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 88 C79000-G8976-C186-03 6.4 Slot Numbers of the Modules and Covers Specifying the Slot Number The three preinstalled modules, the media modules, the covers for unused slots and the dummy cover for s...
Page 89 - Defaults; DIL Switches; STBY; Further Device Properties
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 89 6.5 Factory Defaults DIL Switches When supplied, the four DIL switches on the switch are set to OFF as default. Notice Before starting up for the first time, check the switch...
Page 90 - Polarity Reversal Protection X1, X2; + 24 V power supply 1
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 90 C79000-G8976-C186-03 6.6 Ports 6.6.1 Power Supply Connectors (X1) Polarity Reversal Protection X1, X2 The two 4-pin male connectors (X1, X2) for the power supply and the signaling contact have no...
Page 92 - Digital input 1
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 92 C79000-G8976-C186-03 6.6.3 Digital Input Connectors (X1) Polarity Reversal Protection X1, X2 The two 5-pin male connectors (X1, X2) of the digital inputs 1 through 8 have no polarity reversal pro...
Page 93 - Digital input 5
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 93 6.6.4 Digital Input Connectors (X2) Digital inputs 5 through 8 are connected using a 5-pin connector at the rear termi-nal block on the DI module. X 2 X 1 I N 5 I N 8 I N 7 M...
Page 94 - Connectors for the Twisted Pair Cables; The FastConnect Cabling System
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 94 C79000-G8976-C186-03 6.6.5 Connectors for the Twisted Pair Cables The FastConnect Cabling System With the IE FC RJ-45 Plug and the FastConnect cables (FC), you can achieve a segment length up to ...
Page 95 - Connecting TP Cord to FC Cable; IE FC RJ-45 modular outlet insert 1GE
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 95 Connecting TP Cord to FC Cable To connect TP Cord to FC cables, two IE FC RJ-45 modular outlet insert types are available: ● IE FC RJ-45 modular outlet insert 1GE 1 R-J45 jac...
Page 98 - Removing the FC Cable from SCALANCE X414-3E
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 98 C79000-G8976-C186-03 Removing the FC Cable from SCALANCE X414-3E Under some circumstances, a screwdriver is necessary to remove the twisted pair cables with RJ-45 plugs because it may not be poss...
Page 99 - Gigabit Transmission with FOC
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 99 6.6.6 Connectors for Fiber-Optic Cables Gigabit Transmission with FOC Data transmission at 1 Gbps is over multimode FOC or single mode FOC. In both cases, the fiber-optic cab...
Page 100 - Fast Ethernet Transfer with FOC
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 100 C79000-G8976-C186-03 Fast Ethernet Transfer with FOC Data transmission at 100 Mbps is over multimode FOC or single mode FOC. In both cases, the BFOC plug on the fiber-optic cable is plugged into...
Page 101 - Controls; Switches
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 101 6.7 Operator Controls 6.7.1 DIL Switches Below the labeling strip on the Switch CPU, on slot 4, there are four DIL switches. These DIL switches can have one of two states ( ...
Page 102 - ON; Switch Status
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 102 C79000-G8976-C186-03 Notice Changing the switch settings during operation causes fault displays and activates the signaling contact. The settings are adopted only after the device is restarted. ...
Page 103 - Ring Ports in Slots 5 to 7
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 103 Ring Ports in Slots 5 to 7 If R1 and R2 are set to OFF , the two gigabit ports of slot 5 are selected as ring ports. Note If the SCALANCE X414-3E is operated without media m...
Page 104 - Possible Settings of the Ring Ports
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 104 C79000-G8976-C186-03 Possible Settings of the Ring Ports Note Only two ports of a switch can ever be defined as ring ports. All other ports in slots 6 and 7 that are not defined as ring ports ca...
Page 105 - Changing the display modes
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 105 6.7.2 SELECT / SET Button The SELECT / SET button is used to switch over the display modes (DMode). After turning on the SCALANCE X414-3E, it is in DMode A. The button has t...
Page 106 - Display; Power Module
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 106 C79000-G8976-C186-03 6.8 LED Display Overview The following table shows the states indicated by the LEDs in the various display modes. For more detailed information, refer to the subsections lis...
Page 107 - Behavior; LED on; Fault occurred
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 107 6.8.1 Startup Behavior of the SCALANCE X414-3E During device startup, the red LED on the power module signals the current status of the device. For more detailed information...
Page 109 - Display Modes A through C; Label Color
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 109 6.8.3 LED Display - Power Module Display Modes A through C In display modes A through C, the two LEDs DM1 and DM2 of the Switch CPU are lit as described in section 6.8.2. In...
Page 110 - Display in Display Mode D
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 110 C79000-G8976-C186-03 Display in Display Mode D In display mode D, both the DM1 and DM2 LEDs of the Switch CPU are on. This mode indicates whether the power supply is being monitored with the sig...
Page 111 - LED Display of the Digital Inputs 1 through 8
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 111 6.8.4 LED Display - DI Module LED Display of the Digital Inputs 1 through 8 The status of four digital inputs (IN1 through IN4 or IN5 through IN8) can be indi-cated by the f...
Page 112 - Display Modes A through D
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 112 C79000-G8976-C186-03 6.8.5 LED Display - Switch CPU Display Modes A through D The set display modes are indicated as follows: D M o d e A D M o d e B D M o d e C D M o d e D R M S T B Y D M 1 D ...
Page 113 - Port Statuses in DMode A; Port Color Status
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 113 6.8.6 LED Display of the Ports (DMode A through DMode D) The two LEDs of slot 5 or the four LEDs of slots 9 through 11 of the basic device indicate various port statuses dep...
Page 114 - Port Statuses in DMode B
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 114 C79000-G8976-C186-03 Port Statuses in DMode B In display mode B, the current transmission rate is displayed. Port Color Status Meaning P1 P2 P3 P4 off Port operating at 10 Mbps Green on Port ope...
Page 115 - Port Statuses in DMode C; off
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 115 Port Statuses in DMode C In display mode C, the current mode (half duplex, full duplex) is indicated. Port Color Status Meaning P1 P2 P3 P4 off Port operating in half duplex...
Page 116 - Port Statuses in DMode D; In display mode D, you can see whether or not the port is monitored.
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 116 C79000-G8976-C186-03 Port Statuses in DMode D In display mode D, you can see whether or not the port is monitored. Port Color Status Meaning P1 P2 P3 P4 off The port is not monitored; in other w...
Page 117 - Replacing the C-PLUG; Inserting the C-PLUG in the Slot
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 117 6.9 Replacing the C-PLUG Removing the C-PLUG It is only necessary to remove the C-PLUG if there is a problem on the basic de-vice. After removing the labeling strip, the upp...
Page 118 - Location; Determining the Location of a SCALANCE X-400; With the PST Tool V3.0, you can trigger this function with
Installation and Commissioning Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 118 C79000-G8976-C186-03 6.10 Show Location Determining the Location of a SCALANCE X-400 To identify a SCALANCE X414-3E locally and with certainty, you can use the "show location" function o...
Page 119 - Technical Specifications; Interfaces
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 119 Technical Specifications 7 7.1 SCALANCE X414-3E Interfaces Connecting end devices or network segments over twisted pair 2 x RJ-45 jack (10/100/1000 Mbps) 12 x RJ-45 jack (10/100 Mbps) All electrical ports...
Page 121 - Permitted Environmental Conditions; MTBF information (mean time between failure); Device
Technical Specifications Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 121 Permitted Environmental Conditions / EMC Operating temperature 0°C through + 60°C Storage/transport temperature - 40°C through + 80°C Relative humidity in operation < 95% (no c...
Page 131 - Approvals, Certificates; CE Marking; Voltage Limits” (Low Voltage Equipment Directive)
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 131 Approvals, Certificates Note The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by ...
Page 132 - EMC Directive; The products are designed for use in an industrial environment:; Requirements; Industry; Explosion Protection Directive; II 3 G EEx nA II T3...T6; Required FDA and IEC labels; The listed media modules meet the FDA and IEC requirements.; F D A; C L A S S 1 L A S E R P R O D U C T; FDA and IEC labels are not required for media module MM491-2.
Approvals, Certificates Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 132 C79000-G8976-C186-03 EMC Directive The products are designed for use in an industrial environment: Requirements Area of Application Noise emission Noise immunity Industry EN 61000-6-4 : 2001 EN 61000-6...
Page 133 - Directive on Machines
Approvals, Certificates Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 133 Directive on Machines The product remains a component in compliance with Article 4 (2) of the EU direc-tive on machines 89/392/EEC. According to the directive on machines, we are o...
Page 134 - Note for Australia; Underwriters Laboratories (UL) complying with Standard UL 60950-1; UL Approval Industrial Control Equipment; Underwriters Laboratories (UL) complying with Standard UL 508; CSA Approval Information Technology Equipment
Approvals, Certificates Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 134 C79000-G8976-C186-03 Note for Australia The product complies with the requirements of the AS/NZS 2064 standard (Class A) UL Approval Information Technology Equipment Underwriters Laboratories (UL) comp...
Page 135 - cULus Approval Information Technology Equipment; cULus Approval Industrial Control Equipment; Underwriters Laboratories Inc. complying with; cULus Approval Hazardous Location; Underwriters Laboratories Inc. complying with
Approvals, Certificates Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 135 cULus Approval Information Technology Equipment cULus Listed 60E9 I. T. E. Underwriters Laboratories Inc. complying with ● UL 60950-1 (Information Technology Equipment) ● CSA C22.2...
Page 136 - FM Approval; The product complies with the requirements of the standards; ATEX Approval; The product complies with the requirements of the standard
Approvals, Certificates Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches 136 C79000-G8976-C186-03 ! Warning In hazardous areas, personal injury or damage to property may occur if you make or break an electrical circuit while a SCALANCE X-400 is in operation. Do not connect or d...
Page 137 - Certification
Approvals, Certificates Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 137 Certification The products and systems listed in this document are manufactured and marketed using a quality management system complying with DIN ISO 9001 and certified by DQS (cer...
Page 139 - Glossary
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 139 Glossary Aging time The aging time is the time after which a learned MAC address is dis-carded if a SCALANCE X-400 has not received frames with this sender address during this time. Autocrossover Techniqu...
Page 143 - Store and forward; Virtual LAN within a physically existing network.
Glossary Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 143 Store and forward In this switching technique, the entire frame is read in, before it is for-warded by the switch. A packet is only passed on if it is error-free. TELNET With this protocol, an in...
Page 145 - Index; Fast Ethernet media module MM491-
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches C79000-G8976-C186-03 145 Index A Accepted status ....................................... 44 Autonegotiation ....................................... 24 B Basic device ............................................ 21 C Cabling ........
Page 147 - A&D Technical Support
A&D Technical Support Worldwide, available 24 hours a day: Beijing Nuernberg Johnson City Worldwide (Nuernberg) Technical Support 24 hours a day, 365 days a year Phone: +49 (0) 180 5050-222 Fax: +49 (0) 180 5050-223 Internet: www.siemens.de/ automation/support- request GMT: +1:00 Europe / Africa...
Page 148 - Service & Support on the Internet; where you will find the following:
A&D Technical Support A&D Technical Support Service & Support on the Internet In addition to our documentation, we offer our Know-how online on the internet at: http://www.siemens.com/automation/service&support where you will find the following: • The newsletter, which constantly pro...