SIMATIC Modular Controllers

59

Point-to-point connection

Point-to-point link via communications processors (CPs) is an
extremely powerful and low-cost alternative to bus systems.
The advantage of point-to-point links over bus systems is es-
pecially pronounced when only a few (RS 485) devices are to
be connected to the SIMATIC S7.

The CPs can also easily link third-party systems to the
SIMATIC S7. Thanks to the great flexibility of the CPs, different
physical transmission media, transmission rates or even cus-
tomized transmission protocols can be implemented.

The CPs have a rugged plastic housing with LEDs for displaying
operating states and faults.

For each CP there is a configuring package on CD with elec-
tronic manual, parameterization screen forms and standard
function blocks for communication between the CPU and
the CP.

The configuration data are stored in a system block and
backed up in the CPU. When modules are replaced, the new
module is therefore immediately ready for use.

With the S7-400 point-to-point link modules, adaptation to
the physical transmission media is achieved by plugging in the
relevant interface submodules, without the need for external
converters.

Point-to-point links for SIMATIC S7-400

Scanner
Barcode
reader

Process
controller

SIMOVERT
SIMOREG

Modem

PC

Printer

Robot
control

BDE
terminal

3rd party
PLC

G_

S

T

7

0

_

X

X

_

0

0

6

8

7

SIMATIC S7

Technical data: Point-to-point connection
Application

High-speed

response

with low data volumes

Interconnection

Low-cost:

With one variable
interface

High-speed

:

With two variable inter-
faces

Transmission rate

High (115 200 bit/s)

Low (38 400 bit/s)

High (115 200 bit/s)

Loadable protocols

(Order No. group: 6ES7 340-)

MODBUS Master (-1AA.),

MODBUS Slave (-1AB.),

Data Highway (-1AE.)

Module

CP 440

CP 441-1

CP 441-2

Order No. group: 6ES7

440-1.

441-1.

441-2.

Physical transmission media

RS 232C (V.24)

All transmission methods, all interface modules,

plug-in, serial

20 mA (TTY)
RS 422/485 (X.27)

●

(up to 32 nodes)

Integrated transmission protocols

ASCII

●

Printer driver

●

3964 (R)

●

RK 512

●

SIMATIC_Controller_032011_en.book Seite 59 Montag, 4. April 2011 2:35 14

© Siemens AG 2011

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Siemens
Model
S7-400
Document type
User Manual
Language(s)
English
Pages
1
File size
169.4 KB
Format
PDF

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.