Table of Contents:

  • Page 2 – Central controllers/Expansion units; Design; Possible configurations of the S5Ć155H
  • Page 3 – Principle of operation; 35U central controller; Backup battery; Additional manuals
  • Page 4 – Possible configurations of S5Ć155H; Ordering data; 55H central controller
  • Page 5 – Application
  • Page 7 – EG 185U expansion unit; Possible configurations when connected
  • Page 9 – Possible configurations
Loading the manual

SIMATIC S5Ć135U, S5Ć155U/H

Central controllers/Expansion units

4/127

Siemens ST 50 · 1998

135U/155U central controller

Application

The 135U/155U central conĆ

troller can be used optionally

for the construction of a

S5Ć135U, S5Ć155U or

S5Ć155H programmable conĆ

troller.

Two 135/155U central controlĆ

lers are required for a

S5Ć155H programmable conĆ

troller.

Design

The 135U/155U central conĆ

troller comprises:

21 free slots

1 power supply chassis with

builtĆin fan

S5-135U, S5-155U

Depending on the extent of

the automation task, the cenĆ

tral controller can be

equipped with the following

CPUs:

CPU 948 (max. 4)

CPU 928B (max. 4)

CPU 928 (max. 4)

CPU 922 (max. 4)

All CPUs can also operate

jointly in multiprocessor

mode. When more than one of

these central modules is used

a 923A/923C coordinator is

required (see page 4/30).

S5-155H

One CPU 948R can be used

per central controller.

Power supply chassis

Redundant twoĆoutĆofĆthree

fan concept;

Should one fan cease operĆ

ating the speed of the other

fans is increased thus enabĆ

ling the programmable conĆ

troller to continue operation.

The defective fan can be reĆ

placed while the controller is

in operation

Redundant oneĆoutĆofĆtwo

battery concept;

In the case of a failure of the

main battery (Li battery) the

accu battery switches on

automatically for a period of

three weeks

Mains buffering to NAMUR:

20 ms

Enhanced electromagnetic

compatibility (EMC)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Central controllers/Expansion units; Design; Possible configurations of the S5Ć155H

SIMATIC S5Ć135U, S5Ć155U/H Central controllers/Expansion units 4/128 Siemens ST 50 · 1998 135U/155U central controller (continued) Design PG MUX function via 923C coordinator 923 A/C coordinator CPU 922, CPU 928A, CPU 928B CPU 948 IM 300Ć5, IM 301Ć5 interface modules 2) IM 300Ć3, IM 301Ć3, IM 304, I...

Page 3 - Principle of operation; 35U central controller; Backup battery; Additional manuals

SIMATIC S5Ć135U, S5Ć155U/H Central controllers/Expansion units 4/129 Siemens ST 50 · 1998 135U/155U central controller (continued) Principle of operation Multiprocessor operation When using several CPUs, every single one processes the tasks assigned to it indeĆ pedently from the others. EvĆ ery CPU ...

Page 4 - Possible configurations of S5Ć155H; Ordering data; 55H central controller

SIMATIC S5Ć135U, S5Ć155U/H Central controllers/Expansion units 4/130 Siemens ST 50 · 1998 155H central controller Application The ZG155H central controller is suitable for building a comĆ plete S5-155H programmable controller in a module subĆ rack. Design The central controller 155H is a module subr...