Page 2 - Introducing the Siemens Revised P1 Panelboard
P1 Panelboards • Quick reference for selection and application ii Introducing the Siemens Revised P1 Panelboard Siemens is proud to introduce new, innovative additions to the P1 series of panelboards. The new “Revised P1” Panelboard increases the flexibility and customization options available in Si...
Page 3 - All FT and NFT are invertable in field – Top-feed or Bottom-feed; FT
iii P1 Panelboards • Quick reference for selection and application Revised P1 Panelboard 250 & 400A All FT and NFT are invertable in field – Top-feed or Bottom-feed • Invertability• Flexibility 20” Wide Unit Space 18 30 42 54 66 Box Sizes 26” 32” 38” 44” 50” Box Sizes 56” 62” 68” 74” 250A MLO/MB...
Page 6 - Revised P1 Panelboard FAQ’s
P1 Panelboards • Quick reference for selection and application vi 1. Non-Feed-thru (NFT) variations of the P1 Panels are now available for Factory assembled only (not UPB): • Feed-Thru (FT) versions are versions with a Sub-feed space that can be occupied by Feed-thru lugs, Subfeed Breaker or an SPD ...
Page 7 - Index; Revised P1 Factory Assembled Panelboards
1 P1 Panelboards • Quick reference for selection and application Index Revised P1 panelboards quick reference guide for selection and application Description Page Introduction ii Revised P1 Panelboard Overview iii Revised P1 Panelboard FAQs vi Revised P1 Factory Assembled Panelboards General Informa...
Page 9 - General Specifications
3 P1 Panelboards • Quick reference for selection and application General Specifications Service Entrance Equipment When a panelboard is used as service entrance equipment, it must be located near the point of entrance of building supply conductors. In a main lugs only panel, the number of breakers o...
Page 10 - Catalog Numbering System; Revised P1 panelboards
P1 Panelboards • Quick reference for selection and application 4 Catalog Numbering System Revised P1 panelboards Type of Panel P1 Voltage and System* C = 208Y/120 3Ø 4 W Wye AC R = 415/240 3Ø 4 W Wye AC E = 480Y/277 3Ø 4 W Wye AC S = 440/250 3Ø 4 W Wye AC D = 240 3Ø 3 W Delta AC L = 600/347 3Ø 4 W W...
Page 11 - Application; Type P1 Panelboards
5 P1 Panelboards • Quick reference for selection and application Application Type P1 Panelboards Table P1-3 – Main Breaker Panel Size Selector – Revised P1 Max Ampere rating Main Breaker Types Max # Poles FT 1 Max # Poles NFT Dimensions in inches (mm) Unit Space Box Height B Weight in Lbs. (kg) FT A...
Page 15 - Typical Catalog Numbers
9 P1 Panelboards • Quick reference for selection and application Typical Catalog Numbers Type P1 Panelboards 2 No sub-feed space only for 400A 66 circuit. 3 BL/BQD/GB Type Mains are only available as Back-Fed. No kits are available for use in Main or Sub-feedspace. (GB Type includes NGB, HGB and LGB...
Page 16 - Standard Modifications; Panel Options
P1 Panelboards • Quick reference for selection and application 10 Standard Modifications Type P1 Panelboards Panel Options Enclosures • Extra gutter to sides or ends of the can • 24” wide boxes • Hinged trims • Door-in-door trims • Screw to the box trims • Piano hinge trims • Painted boxes • Custom ...
Page 17 - Miscellaneous Modifications; Enclosure Modifications
11 P1 Panelboards • Quick reference for selection and application Miscellaneous Modifications Type P1 Panelboards Enclosure Modifications Compression Lugs Remote Switch Modifications Table P1-19 – Lugs Style Amp Rating Breaker Type Compression Connectors Box Height Addition MLO 125 N/A (1) #6 AWG - ...
Page 18 - Dimensions
P1 Panelboards • Quick reference for selection and application 12 20 in. [ 508 ] 5.75 in. [ 146 ] ³⁄₄ in. [ 19 ] ³⁄₄ in. [ 19 ] Dimensions Type P1 Panelboards Type 1 Box Box is symmetrical 1 Dimensions are interior of the box. Add 5/8" to width for absolute dimension. Add 1/8" to height for ...
Page 20 - New Revised P1 Unassembled Panelboards
P1 Panelboards • Quick reference for selection and application 14 New Revised P1 Unassembled Panelboards Flexibility and ease of assembly: Customer oriented design creates installation convenience. For all of its one-of-a-kind features, the P1 panelboard is also designed to be extremely userfriendly...
Page 21 - Unassembled Panelboards
15 P1 Panelboards • Quick reference for selection and application Catalog Numbering System Unassembled Panelboards Note: Revised P1 was introduced in June 2014. All original P1 devices do not include the "Subfeed Space" Indicator. All original P1 included the Subfeed Space as standard. Type ...
Page 22 - Distributor Stock; Type P1 Unassembled Panelboards (Revised P1 introduced 2014)
P1 Panelboards • Quick reference for selection and application 16 Distributor Stock Type P1 Panelboards Product Category UPB Type P1 Unassembled Panelboards (Revised P1 introduced 2014) Pricing An Unassembled Panel400A Max. — 20" Wide x 5.75" Deep 1. Choose the appropriate Interior from the ...
Page 24 - Warehouse Stock/Unassembled; Main Breaker Mounting Kits with Breakers for P1 Panels; (250A and lower can be used as subfeed kits also); Branch Breakers Selection
P1 Panelboards • Quick reference for selection and application 18 Warehouse Stock/Unassembled Main Breaker Mounting Kits with Breakers for P1 Panels (250A and lower can be used as subfeed kits also) Product Category UPB Selection Guide 1. Select breaker type. 2. Select required amperage. 3. Select n...
Page 25 - Warehouse Stock / Unassembled; Branch Breakers Selection for P1; GB Family Branch Breakers
19 P1 Panelboards • Quick reference for selection and application Warehouse Stock / Unassembled Type P1 Panelboards Selection Guide 1. Select breaker type. 2. Select required amperage. Branch Breakers Selection for P1 n Built to order. Allow 2–3 weeks for delivery. HACR rated. b To add shunt trip ...
Page 26 - Surge Protection Device (SPD) for Revised P1 Lighting Panelboards; (for Original P1 – refer to TPS3 01 Series)
P1 Panelboards • Quick reference for selection and application 20 TPS3 02 Surge Protection Device (SPD) for Revised P1 Lighting Panelboards (for Original P1 – refer to TPS3 01 Series) UL 1449 3rd Edition SPD These newly developed kits are for use in the new revised P1 Series only. Interior part numb...
Page 27 - oo
21 P1 Panelboards • Quick reference for selection and application • SPD Features – UL 1449 3rd Edition effective September 2009 – Designed, manufactured & tested consistent with: – ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002 – 1992/2000 NEMA LS-1 – NEC Article 285 – IEC 61643, CE – L...
Page 28 - TPS3 L2 - True 10 Mode Protection; (for Original P1 – refer to TPS3 L1 Series)
P1 Panelboards • Quick reference for selection and application 22 UL 1449 3rd Edition SPD TPS3 L2 - True 10 Mode Protection Surge Protection Device (SPD) for Revised P1 Lighting Distribution Panelboards (for Original P1 – refer to TPS3 L1 Series) These newly developed kits are for use in the new rev...
Page 29 - Figure■1; Figure 1; Figure 2
23 P1 Panelboards • Quick reference for selection and application • SPD Features – UL 1449 3rd Edition effective September 2009 – Designed, manufactured & tested consistent with: – ANSI/IEEE C62.41.1-2002, C62.41.2-2002, and C62.45-2002 – 1992/2000 NEMA LS-1 – NEC Article 285 – IEC 61643, CE – L...