Siemens LFL Series - User Manual
Siemens LFL Series – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Brahma CM32 EUROFLAT; White-Rodgers 50A72 HSI Control; Remote flame failure reset; Wiring kits available for all Brahma Microflat controllers; ct
- Page 3 – System Control Engineering NZ Ltd; Programmed oil & gas Burner Control s; Oil Burner Safety Control; Oil Burner Safety Control
- Page 4 – CONTROLLER
- Page 9 – QRB flame detector; Siemens LFL Test Box; Bypass/measure switch for flame; test eQuiPment
- Page 10 – semi automatiC Burner Control s; Kromschroder IFW 15 CONTROL
- Page 11 – Siemens LFE 10 CONTROL
- Page 12 – Fl ame deteCtors; Siemens QRA4U; wire cable; Brahma UV1; #SA1881w White Medium Sensitivity
Brahma CE11 U MICROFLAT
Restart attempt
•
Plug in electrical connections
•
Single gas valve
•
Volatile lock-out
•
Pre-purge 1.5 seconds
•
Flame failure safety time 10
•
seconds
Ionization flame electrode control
•
240 or 110 volt AC
•
#B1150
Brahma CM11 U MICROFLAT
Restart attempt
•
Plug in electrical connections
•
Single gas valve
•
Non Volatile lock-out
•
Pre-purge 1.5 seconds
•
Flame failure safety time
•
10 seconds
Ionization flame electrode control
•
240 or 110 volt AC
•
#B1152
Brahma CE12 U MICROFLAT
Restart attempt
•
Plug in electrical connections
•
Pilot / Main Gas (2 valves)
•
Volatile lock-out
•
Pre-purge 1.5 seconds
•
Flame failure safety time 10
•
seconds
Ionization flame electrode control
•
240 or 110 volt AC
•
#
B1154X
Burner Control s with integral ignition
System Control Engineering NZ Ltd
For Gas Combustion & Control Equipment
Tel : 09-636-1401 • Fax: 09-636-1525 • [email protected] • www.systemcontrol.co.nz
Brahma CM12 U MICROFLAT
Restart attempt
•
Plug in electrical connections
•
Pilot / Main Gas (2 valve)
•
Non Volatile lock-out
•
Pre-purge 1.5 seconds
•
Flame failure safety time
•
10 seconds
Ionization flame electrode control
•
240 or 110 volt AC
•
#B1154
Brahma CE31 U MICROFLAT
Restart attempt
•
Plug in electrical connections
•
Single gas valve
•
Volatile lock-out
•
Pre-purge 1.5 seconds
•
Flame failure safety time
•
10 seconds
Ionization flame electrode control
•
240 or 110 volt AC
•
Air pressure Proving / Fan
•
#B1156
Typical Photo
Non Volatile Lock out versions require an external re set button to reset.
6.1
Se
ct
io
n 6
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Brahma CM32 EUROFLAT Restart attempt • Plug in electrical connections • Pilot and Main gas valves • Non Volatile lock-out • Pre-purge - 5 or 30 seconds • Flame failure safety time - • 5 seconds Remote flame failure reset • Ionization flame electrode control • 240 or 110 volt AC • Fan control with ai...
FENWALL BURNER CONTROL C/W WIRINg LOOM 12 VDC • Integral Ignition transformer • Inter purge time 25 seconds • Trial for ignition time ( TFI ) 10 • seconds # FW-35-53056-035 System Control Engineering NZ Ltd For Gas Combustion & Control Equipment Tel : 09-636-1401 • Fax: 09-636-1525 • [email prot...
Satronic TF830.3 - OIL BURNER CONTROLLER Oil burner control • Plug in base (SA7531001) • Single stage operation • MZ 770S / UVD 970 Flame detector • Pre - purge 12 seconds • Post ignition time 2 - 5 seconds • Manual reset from lockout • 240 volt AC • #SA02231 1 A Honeywell Company For 1- or 2-stage ...