Siemens EH.85M.21E - User Manual
Siemens EH.85M.21E – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Issue 1; Introduction; ’ and switching the power off and back; Do not change any timings or other settings on the
- Page 3 – Connections
- Page 4 – Main Processor LED’s; There are four LED’s on the front of the main processor card.
- Page 5 – Self Test; identifies the test which has failed; General Lamp Switch Card Failures:
- Page 6 – Mains Freq Error
- Page 7 – Caution
- Page 8 – should be covered before proceeding any further with the; Checks that it can detect a lamp supply
- Page 10 – Handset Introduction; ’ when a PC / IPT is being used as a handset.; Setting the Date and Time; Entering ‘TOD’ now displays the date as well as the time.
- Page 11 – Fault Log
- Page 16 – Lamp Monitoring
- Page 17 – KLD END OF LOG
- Page 19 – Visit Information; TOD
- Page 20 – Serial Numbers
SIEMENS TRAFFIC CONTROLS LIMITED
667/HB/27000/100
Sopers Lane
POOLE Dorset.
BH17 7ER
SYSTEM/PROJECT/PRODUCT: ST800
SIEMENS TYPE 800
TRAFFIC CONTROLLER
GUIDANCE NOTES
P
REPARED
: Paul Cox
F
UNCTION
: Software Engineer
THIS DOCUMENT IS ELECTRONICALLY HELD AND APPROVED
Issue
Change Ref.
Date
1
n/a
11 March, 1998
© Siemens plc. 1998 All rights reserved.
The information contained herein is the property of Siemens plc. and is supplied
without liability for errors or omissions. No part may be reproduced or used except
as authorized by contract or other written permission. The copyright and the
foregoing restriction on reproduction and use extend to all media in which the
information may be embodied.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
ST800 Guidance Notes Page 2 667/HB/27000/100 Issue 1 Introduction The following pages summarize how to use the new ST800 traffic controller fromSiemens. It assumes knowledge of the T400 and therefore concentrates on thedifferences between the two types of controller. Following these pages is a blank...
ST800 Guidance Notes Issue 1 667/HB/27000/100 Page 3 Connections The following diagrams detail the connections on the back of the power distributionunit and the back of one of the lamp switch cards. The back of all the lamp switchcards are identical, except it should be noted that the ZXO wires, the...
ST800 Guidance Notes Page 4 667/HB/27000/100 Issue 1 The following diagram shows the connections in the power connector on the back ofthe main processor card. Any signal name proceded with an exclamation mark (‘!’) isactive-low, i.e. 0v is the active state. The values in brackets, e.g. (24v), show t...