Siemens EF 725 Series - User Manual

Siemens EF 725 Series

Siemens EF 725 Series – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – minimum span
  • Page 3 – TX; ELECTRICAL CHARACTERISTICS AND OPTIONS; MINIMUM OPERATING VOLTAGES; Supply voltage; Total loop resistance; HART digital communication
  • Page 6 – amb; Terminal block
  • Page 7 – CONFIGURATION
  • Page 8 – MOUNTING DIMENSIONS; Transmitter with barrel housing
  • Page 9 – Wafer type seal; OF; SIZE; Capillary to; ELECTRICAL CONNECTIONS; • HART Version
  • Page 10 – PRODUCT CODE; abcde f g hijk l m n op; Code; Material
  • Page 12 – ORDERING INFORMATION; ab c d e f
Loading the manual

1

600T EN Series Pressure Transmitters

Model 621EM
Liquid level, interface and density

Specification sheet

The all new 600T Series transmitter
The first choice pressure transmitter is
now an even bigger choice

High installed base accuracy :

±

0.10%

Reliable inductive sensing system coupled

with the very latest digital technologies

- ensures high performance at all process

conditions

Specific design for low pressure

Wide selection of materials

- meet virtually all process requirements

HART 4-20 mA, Profibus PA, FF versions

with plug-and-play electronics replacement

- provides interchangeability for upgrading

transmitter

Local snap calibration and full management

via hand terminal or PC-running software

HART®, Profibus PA, FF communications

- allows integration with standard process bus

CoMeter display option

- offers HART Configuration capabilities

combined with local indication

Ecoefficient life cycle

- e n s u r e s l o w e n v i r o n m e n t a l i m p a c t i n

compliance with LCA assessment to ISO

14040 standard

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - minimum span

2 Sensor code Upper Range Limit (URL) 621EM Liquid level interface, density Lower Range Limit (LRL) 2.5 kPa25 mbar10 inH 2 O 10 kPa100 mbar40.1 inH 2 O A B - 2.5 kPa- 25 mbar- 10 inH 2 O - 10 kPa- 100 mbar- 40.1 inH 2 O Minimum Span 0.25 kPa2.5 mbar1 inH 2 O 1 kPa10 mbar4 inH 2 O FUNCTIONAL SPECIFIC...

Page 3 - TX; ELECTRICAL CHARACTERISTICS AND OPTIONS; MINIMUM OPERATING VOLTAGES; Supply voltage; Total loop resistance; HART digital communication

3 Sensor (URL) coefficient K5 The seal(s) constant time is calculated by the following formula T S6 (sec) = [K1 x (K2 + K3 x K4) x K5] The total constant time of the transmitter/seal system is thecombination of relevant response times by the followingformula: T TX (sec) = T TR + T S6 ) x 1.2] + 0.1 ...

Page 6 - amb; Terminal block

6 Environmental protection Wet and dust-laden atmospheres The transmitter is dust and sand tight and protected againstimmersion effects as defined by IEC 529 (1989) to IP 67 (IP 68on request) or by NEMA to 4X or by JIS to C0920 Hazardous atmospheres With or without output meter/integral displayINTRI...