Page 2 - Siemens Aktiengesellschaft
Safety Guidelines This operating manual contains notices which you should observe to ensure your own personal safety, aswell as to protect the product and connected equipment. These notices are highlighted in the manual by awarning triangle and are marked as follows according to the level of danger:...
Page 3 - Contents
iii SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Contents Welcome to your SIMATIC Box PC 620 v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Information about this Manual vii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - Error Diagnosis and Reinstallation
Contents iv SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 6 Error Diagnosis and Reinstallation 6-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 Problems When Using Modules from Other Manufacturers 6-2 . . . . . . . . . . . . 6.2 The Monitor Remains Dar...
Page 5 - Welcome to your SIMATIC Box PC 620; Overview; The SIMATIC Box PC 620 has a high quality standard. For example:
v SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Welcome to your SIMATIC Box PC 620 Overview The SIMATIC Box PC 620 serves as an entry-level system for PC-basedautomation, a basic component for PC-based HMI devices (Panel PC), a basiccomponent for PC-based machine control panels (OP031, OP0...
Page 6 - Range of Application
Welcome to your SIMATIC Box PC 620 vi SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Range of Application The SIMATIC Box PC 620 is a basic device for high performance automationsolutions. It meets the highest requirements through: • compliance with the requirements for a fire enclosure to...
Page 7 - Consignment/Assessories
Welcome to your SIMATIC Box PC 620 vii SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Consignment/Assessories • Basic unit with preinstalled operating system • Power cord for AC supply or connector for DC supply (depending on deviceconfiguration) • Installation material (depending on device...
Page 8 - Using the Manual; The following table serves as a guideline:; Initial Situation; Conventions; Convention; Other Documentation for the SIMATIC Box PC 620
Welcome to your SIMATIC Box PC 620 viii SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Using the Manual You can work with the operating manual in various ways. Either go through thechapters in turn or, depending on the initial situation, read the overview at thebeginning of the chapter to ...
Page 9 - Important Information; Safety Instructions; Caution; Installation; Warning
1-1 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Important Information 1.1 Safety Instructions ! Caution The safety instructions given on the reverse of the title page of this manual mustbe observed. Before adding to the SIMATIC Box PC 620’s functionality byexpanding the hardware configur...
Page 10 - Power Connection
Important Information 1-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Power Connection The device is intended for service in grounded electricity supply systems(TN systems to VDE 0100, part 300, or IEC 364–3). Service in non-grounded or impedance-grounded supply systems (IT systems) isn...
Page 11 - Country-Specific Information; For the United States and Canada:; Repairs
Important Information 1-3 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Country-Specific Information For the United States and Canada: In the United States and Canada USA, a CSA or UL-listed power supply cablemust be used. The male plug is a 5-15 style. For operation with 120 V: Use a UL L...
Page 12 - Battery; Note; Notes on Inserting and Removing Modules; Devices and tools must be free of static electricity.
Important Information 1-4 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Battery There is a battery on the motherboard in this device. Batteries may only beexchanged by technical personnel. Observe the local regulations on disposal of special waste when disposing of deadbatteries. ! Note T...
Page 13 - Certificates, Directives and Declarations; EMC Directive; Field of Application; Emitted Interference; Low Voltage Directive
Important Information 1-5 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 1.2 Certificates, Directives and Declarations Notes on the CE Symbol The following applies to the SIMATIC product described in thisoperating instruction: EMC Directive This product fulfils the requirements for the EC d...
Page 14 - Software License Agreement; Certification for the USA, Canada and Autralia; Security; US
Important Information 1-6 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 ISO 9001 Certificate The quality assurance system for the whole product process (development,production, and marketing) fulfills the requirements of ISO 9001 (corresponds toEN29001: 1987). This has been certified by t...
Page 15 - EMC; Australia
Important Information 1-7 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 EMC USA Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digitaldevice, pursuant to Part 15 of the FCC Rules. The...
Page 17 - Commissioning the SIMATIC Box PC 620; Unpacking and Checking the Scope of Delivery; Unpacking the; Unpack your SIMATIC Box PC 620 programming device as follows:; Recording the Serial Number
2-1 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Commissioning the SIMATIC Box PC 620 2.1 Unpacking and Checking the Scope of Delivery Unpacking the SIMATIC Box PC 620 Unpack your SIMATIC Box PC 620 programming device as follows: 1. Remove the packing. 2. Do not throw the original packing...
Page 18 - Installing the SIMATIC Box PC 620; Please note the following points when installing the PC:
Commissioning the SIMATIC Box PC 620 2-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 2.2 Installing the SIMATIC Box PC 620 The SIMATIC Box PC 620 can be operated in all the usual fitting positions. It isparticularly suitable for fitting in consoles, switch boards and control panels. The...
Page 19 - Instructions for wall and ceiling mounting; Fix the mounting brackets at the housing of the PC.
Commissioning the SIMATIC Box PC 620 2-3 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Depending on the configuration of the device, two mounting brackets are includedin the scope of delivery. You can attach these to the housing with 6 screws (M3x6). M4 thread, max. depth of engagement 5 m...
Page 23 - An inclined position of + 20; Preferred position; Permissible Fitting Positions of the PC with LS120; An inclined position of; Preferred position
Commissioning the SIMATIC Box PC 620 2-7 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Permissible Fitting Positions of the PC with Floppy Disk Drive An inclined position of + 20 _ is allowed in each of the permissible fitting positions. FDD Interfaces Fan Interfaces FDD Interfaces Fan FDD...
Page 24 - Preparing for Operation; Connection to the Power Supply Unit; Equipotential Measures
Commissioning the SIMATIC Box PC 620 2-8 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 2.3 Preparing for Operation Connection to the Power Supply Unit Note The SIMATIC Box PC 620 is equipped with a safety-tested mains cable and mayonly be connected to a grounded grounding outlet. Make sur...
Page 25 - Connecting and Switching on the SIMATIC Box PC 620; Switching off the SIMATIC Box PC 620
Commissioning the SIMATIC Box PC 620 2-9 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Connecting and Switching on the SIMATIC Box PC 620 Before you connect the SIMATIC Box PC 620 to the mains, the keyboard, mouseand display or monitor must be connected. 1. Insert the connector cable of th...
Page 26 - Transport; Transporting; PC
Commissioning the SIMATIC Box PC 620 2-10 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 2.4 Transport Transporting Despite the fact that the SIMATIC Box PC 620 is of rugged design, its internalcomponents are sensitive to severe vibrations or shock. You must therefore protectyour PC from s...
Page 28 - Hardware Components of the SIMATIC Box PC 620; Without TTY for the basic variant of the Box PC
Hardware Components of the SIMATIC Box PC 620 3-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 3.1 Right-Hand Side of the Device (Port Side) Keyboard Ethernet MPI/DP USB VGA LPT1/Printer Mouse COM1/V24/AG COM2 PCI slot PCI/ISA slot PC Card * 1 * 2 Figure 3-1 Right-Hand Side of the Device...
Page 29 - Connections
Hardware Components of the SIMATIC Box PC 620 3-3 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Connections Function VGA VGA port for connecting an external monitor, 15 pins,subminiature Cannon connector, sockets COM1/V24/AG*3 Serial port 1 (V24, via BIOS-Setup can be switched to TTY), 25 ...
Page 30 - Reset Button; Data loss is possible with a hardware reset.
Hardware Components of the SIMATIC Box PC 620 3-4 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 3.2 Left-Hand Side of the Device (Drive Side) Fan Floppy disk drive Cover for front ports Plastic rivet Name plate Reset button Figure 3-2 Left-Hand Side of the Device Connections Function Devi...
Page 31 - Ports; Front Ports; VGA Port
Hardware Components of the SIMATIC Box PC 620 3-5 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 3.3 Ports Front Ports The front ports are located behind the cover below the floppy disk drive. They areused for connection of the following front elements: • I/O port for the connection of fron...
Page 32 - Connecting USB Devices; Plug the USB cable into the port
Hardware Components of the SIMATIC Box PC 620 3-6 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Connecting USB Devices You can connect peripheral devices with USB interfaces to the USB port. • Plug the USB cable into the port The device connected in this way is available as soon as it has...
Page 33 - Connect Ethernet
Hardware Components of the SIMATIC Box PC 620 3-7 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Connect Ethernet The drivers for the Ethernet interface are pre-installed. A wait period of approxima-tely 30 results if no Ethernet cable in inserted or no active node is found during thestartu...
Page 34 - PC Card Port; The following is to be observed when working with cardbus/PC cards:; Otherwise damage could occur.
Hardware Components of the SIMATIC Box PC 620 3-8 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 3.4 PC Card Port Cardbus cards and PCMCIA cards can be operated through the PC card port ofthe SIMATIC Box PC 620. PC card port Type I/II/III Figure 3-4 PC Card Port The following is to be obse...
Page 35 - Peak currents of 650 mA at 5 V based on 3 s are permitted!; Examples of PCMCIA cards connected to PC card interface for; Hard Disk; Installing PC Cards; Note the following when installing these cards:
Hardware Components of the SIMATIC Box PC 620 3-9 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Note Peak currents of 650 mA at 5 V based on 3 s are permitted! Examples of PCMCIA cards connected to PC card interface for Hard Disk 330 mA read/write (Maxtor MXL-131-III) 640 mA spin up 2 s . ...
Page 36 - Drives; Types of Diskette; You can use following diskettes:; double sided high density diskette; Handling Diskettes with the Floppy Disk Drive; The diskette is inserted in the disk drive as shown below:; Risk of loss of data!
Hardware Components of the SIMATIC Box PC 620 3-10 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 3.5 Drives The SIMATIC Box PC 620 is equipped as standard with a 3.5” disk drive or anLS 120 drive and a 3.5” hard disk drive. 3.5.1 Disk Drive (Depending on the Device Configuration) You can ...
Page 37 - Handling Disks with the LS120-Drive
Hardware Components of the SIMATIC Box PC 620 3-11 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 3.5.2 LS120-Drive (Depending on the Device Configuration) The SIMATIC Box PC 620 can be equipped with an LS120 drive as an alternativeto a floppy disk drive. Larger volumes of data can be store...
Page 38 - Information on the LS120-disk drive; Restrictions; P Tools under STEP 5; Settings in Setup; In the “Main” menu under Boot Options:; Usage notes for LS 120 Superdisks; Track density for Superdisks is 10
Hardware Components of the SIMATIC Box PC 620 3-12 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Information on the LS120-disk drive Restrictions P Tools under STEP 5 Data cannot be edited in PCP/M format on the LS120-drive using P Tools underSTEP 5. Authorization with Authors Vx.x In ord...
Page 39 - Recommended Superdisks:
Hardware Components of the SIMATIC Box PC 620 3-13 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Note In order to achieve a reliable operation and high data security, please note thefollowing during use: • Store and transport the Superdisk in the protective cassette included. Doingthis wil...
Page 40 - Hard Disk Drive; Risk of loss of data and damage to the drive!; Opening the Drawer
Hardware Components of the SIMATIC Box PC 620 3-14 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 3.5.3 Hard Disk Drive The hard disk drive is used for the storage of large quantities of data. it is fitted in amounting which is easily exchangeable and damped against vibration. ! Caution Ri...
Page 41 - Closing the Drawer; inserted is defective and cannot be read.
Hardware Components of the SIMATIC Box PC 620 3-15 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Closing the Drawer Push in the drawer until it closes completely. Do not press the eject button. Note The EJECT function offered by various applications for opening theCD-ROM drawer does not wo...
Page 42 - Risk of data loss and damage to the drive!; Emergency Eject
Hardware Components of the SIMATIC Box PC 620 3-16 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 CD-ROM Front Access LED Drawer Eject button Emergency eject Figure 3-7 CD-ROM Front ! Caution Risk of data loss and damage to the drive! CD-ROM drives are sensitive to vibrations and shock. An...
Page 43 - Backup Battery
Hardware Components of the SIMATIC Box PC 620 3-17 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 3.6 Backup Battery A backup battery (3.6 V lithium battery) powers the hardware clock even after theprogramming device is switched off. There is a battery on the motherboard in this device. Bat...
Page 45 - Connecting Peripheral Devices
4-1 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Connection of System Expansions andExternal Devices 4.1 Connecting Peripheral Devices It is possible to expand the SIMATIC Box PC 620’s functionality by installing additionalmodules. Due to the rugged design and the high functionality the d...
Page 46 - Connection of System Expansions and External Devices
Connection of System Expansions and External Devices 4-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04
Page 47 - Setting up the SIMATIC Box PC 620
5-1 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Setting up the SIMATIC Box PC 620 5
Page 48 - Preparing for Start Up; Powering Up the SIMATIC Box PC 620; – Initial start and; Initial Start of the SIMATIC Box PC 620; Installing the Operating System
Setting up the SIMATIC Box PC 620 5-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 5.1 Preparing for Start Up Powering Up the SIMATIC Box PC 620 Both the operating system and system software supplied with theSIMATIC Box PC 620 are preinstalled on the hard disk and are set up by the timey...
Page 49 - Startup under Windows 98
Setting up the SIMATIC Box PC 620 5-3 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Startup under Windows 98 The operating system is set up once you have entered the requisite information.The Welcome to Windows 98 screen helps you to get familiar with the Desktopuser interface. Now the use...
Page 50 - Complete Restart of the SIMATIC Box PC 620; Electronic Manuals; The PC comes with different electronic manuals. You can find:; The Adobe Acrobat Reader
Setting up the SIMATIC Box PC 620 5-4 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 5.3 Complete Restart of the SIMATIC Box PC 620 Overview Once the SIMATIC Box PC 620’s operating system is set up, the user interface ofthe operating system is displayed following system startup every time ...
Page 51 - Chapter Overview
6-1 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Error Diagnosis and Reinstallation Chapter Overview This chapter provides you with tips on how to localize and troubleshoot frequentlyoccurring problems. • Please look up the meaning of operating system error messages in youroperating syste...
Page 52 - Problems When Using Modules from Other Manufacturers; Error Display
Error Diagnosis and Reinstallation 6-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 6.1 Problems When Using Modules from Other Manufacturers Error Display The PC crashes during power up. Cause The following causes are possible: – Double assignment of I/O addresses – Double assignment of ...
Page 53 - The Monitor Remains Dark; Cause and Remedy; The following causes are possible:; The monitor has been switched off.; Switch on the monitor.; The monitor is in “powersave” mode.; Press any key on the keyboard.; The brightness button has been set to dark.; Switch off the monitor and the system unit.
Error Diagnosis and Reinstallation 6-3 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 6.2 The Monitor Remains Dark Cause and Remedy The following causes are possible: The monitor has been switched off. • Switch on the monitor. The monitor is in “powersave” mode. • Press any key on the keybo...
Page 54 - The Screen Display Does not Appear or Drifts; Select the correct screen driver for your user program.; No Mouse Pointer Appears on the Screen; The mouse pointer may not appear for the following reasons:; The mouse driver is not loaded
Error Diagnosis and Reinstallation 6-4 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 6.3 The Screen Display Does not Appear or Drifts Cause and Remedy Either the incorrect line frequency and/or the incorrect resolution is set for thescreen or for the user program. • Stop the user program....
Page 55 - The Clock Time and/or the Date in Your PC Is Incorrect; Remedy; Set the clock time and the date in the setup menu.; An Error Message Appears on the Screen; Error Messages; Error Message on the Screen
Error Diagnosis and Reinstallation 6-5 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 6.5 The Clock Time and/or the Date in Your PC Is Incorrect Remedy Set the clock time and the date in the setup menu. Press <F2> to call setup when booting the computer. Note The battery is dead if th...
Page 56 - No Connection via COM1/TTY Possible
Error Diagnosis and Reinstallation 6-6 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Error Message on the Screen Meaning/Suggestion Incorrect Drive B typeRun SETUP Check the SETUP entries for drive B. Diskette drive A error Error accessing drive A.Contact your technical support team. Disk...
Page 57 - Beeps
Error Diagnosis and Reinstallation 6-7 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 6.8 Diagnostic Messages (Port 80) When the SIMATIC PC is powered up, it runs a self-test (POST = Power OnSelf-Test). If the POST detects a fault, it outputs the sequence of beeps (beepcode) assigned for th...
Page 58 - The POST codes in order of occurrence:; Display
Error Diagnosis and Reinstallation 6-8 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 The POST codes in order of occurrence: Display (hex) Meaning Description 02 TP_VERIFY_REAL Test whether the CPU is in real mode 1C TP_RESET_PIC Reset the interrupt controller 12 TP_RESTORE_CRO Restore the...
Page 61 - Restoring the Hard Disk; Primary Partition
Error Diagnosis and Reinstallation 6-11 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 6.9 Restoring the Hard Disk 6.9.1 Creating Partitions unter Microsoft Windows 98 After installing a new hard disk it is necessary to create partitions with the program“FDisk” when the partitions have erro...
Page 62 - Creating an Extended Partition; Creating Partitions unter Microsoft Windows 2000
Error Diagnosis and Reinstallation 6-12 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Creating an Extended Partition In order to create an extended partition, you have to first boot from the Windows98 CD as described in steps 1 to 4 above. Using ”A:\>FDisk” start the Recovery CD hard d...
Page 63 - Creating an Extended FAT 32 Partition; Create an extended DOS partition for the rest of the disk space.; Creating Partitions under Windows NT; – a partition of with the FAT16 file system with 2045 Mbytes,
Error Diagnosis and Reinstallation 6-13 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 7. To format the partition from the Recovery CD, as described above in steps 1 to 3, reboot and then format drive C: with the “Format” program. Enter:”A:\>Format C:”(A: is the CD-ROM drive). Creating a...
Page 64 - To boot from the Recovery CD proceed as follows: When the message
Error Diagnosis and Reinstallation 6-14 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 To restore the partitions to their original condition, please do the following: Primary Partition 1. To boot from the Recovery CD proceed as follows: When the message Press <F2> to enter Setup appe...
Page 65 - Installation of the Windows Operating System; Installation of the Recovery CD in Microsoft Windows NT; Windows NT Installation Sequence
Error Diagnosis and Reinstallation 6-15 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 6.10 Installation of the Windows Operating System Dependent on the device model, different operating system CDs are shipped: Microsoft Windows NT or Recovery Microsoft Windows NT,Microsoft Windows 98 SE o...
Page 66 - When “Microsoft Windows 98-Startup Menu” is displayed, select; Start the Windows setup program; Installing the Microsoft Windows 98 Operating System; To boot from the Windows 98 CD proceed as follows: When the message
Error Diagnosis and Reinstallation 6-16 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 4. When “Microsoft Windows 98-Startup Menu” is displayed, select “1. Boot for CD-Recovery”. 5. You have to acknowledge the “SIEMENS End User License Agreement” with the F8 function key. Pressing ESC allo...
Page 67 - Installation of the Recovery CD in Microsoft Windows 98; Windows 98 Installation Sequence; Insert the Recovery CD in the CD-ROM drive and reboot the system.
Error Diagnosis and Reinstallation 6-17 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 4. When “Microsoft Windows 98-Startup Menu” is displayed, select “2. Boot from CD-ROM”. 5. In the “Microsoft Windows 98-Start Menu” select “1. Start Windows 98 Setup from CD-ROM” . Installation of the Rec...
Page 68 - Installing the Recovery CD for Microsoft Windows 2000; Windows 2000 Installation Sequence
Error Diagnosis and Reinstallation 6-18 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 8. Confirm the end massage box. 9. Start the Windows setup program LW:\IWIN98\SETUP.exeLW is the drive where the recovery data have been copied. 10.After starting the setup.exe please follow the screen i...
Page 69 - Setting the Language Selection for Windows 2000
Error Diagnosis and Reinstallation 6-19 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Note By default, drive C: is used for the data transfer (Recovery). Ensure that there is an available disk space of approximately 500 MB left on driveC: after the selected recovery data have been copied. ...
Page 70 - Installing Drivers and Software; Place the “Documentation and Drivers” CD in the CD ROM drive.
Error Diagnosis and Reinstallation 6-20 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 6.11 Installing Drivers and Software To install the drivers and software from the “Documentation and Drivers” CDsupplied, proceed as follows: 1. Place the “Documentation and Drivers” CD in the CD ROM dri...
Page 71 - Technical Specifications
7-1 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Technical Specifications 7
Page 72 - Technical Specifications of the SIMATIC Box PC 620
Technical Specifications 7-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 7.1 Technical Specifications of the SIMATIC Box PC 620 GeneralOrder nos. See order documentation Dimensions (w x h x d) 295x265x80 mm, without CD-ROM drive295x265x100 mm, with CD-ROM drive Weight approx. 6kg (13.5 ...
Page 73 - Mechanical Specifications
Technical Specifications 7-3 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Ambient ConditionsTemperature – operation – storage/transport – gradient tested to DIN EN 60068-2-2:1994, DIN IEC 60068-2-1,DIN IEC 60068-2-14, + 5 ° C to +45 ° C - 20 ° C to +60 ° C (Max. speed of temperature chang...
Page 75 - Hotline Services; Customer Support, Technical Support
8-1 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 Hotline Services 8.1 Customer Support, Technical Support Open round the clock, worldwide: Johnson City Nuremberg Singapore SIMATIC Hotline Worldwide (Nuremberg) Technical Support (FreeContact) Local time: Mon.-Fri. 7:00 to 17:00 Phone: +49 ...
Page 76 - SIMATIC Customer Support Online Services; Further Support; Training Center; SIMATIC Documentation on the Internet; You will find the documentation on the internet at:; Service & Support on the Internet; where you will find the following:
Hotline Services 8-2 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 8.2 SIMATIC Customer Support Online Services Further Support If you have questions related to the use of the products which are not answered inthis manual, please consult your Siemens representative in your local agency. h...
Page 77 - Regional Repair Centers
Hotline Services 8-3 SIMATIC Box PC 620 Operating ManualC79000-Z7076-C638-04 8.3 Regional Repair Centers Region Phone Fax Augsburg +49 (821)2595 599 +49 (821)2595 546 Berlin +49 (30)386 34926 +49 (30)386 34933 Bielefeld +49 (521)291 323 +49 (521)291 538 Bremen +49 (421)364 2093 +49 (421)364 2107 Che...
Page 78 - Country
Hotline Services 8-4 SIMATIC Box PC 620 Operating Manual C79000-Z7076-C638-04 Country Phone Fax Argentina +54 (1) 3408400 +54 (1) 3408400 3163 Australia +61 (3) 9420 7274 +54 (3) 9420 7500 Belgium +32 (2) 536 2905 +32 (2) 536 2880 Brazil +55 (11) 7947 1999 ext.3013 +55 (11) 7947 1888 China +86 (21) ...