Siemens C12 - User Manual

Siemens C12

Siemens C12 – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – SITRANS P; Transmitters for level; Introduction; Mode of operation; Parameterization using
  • Page 3 – Technical data; Application
  • Page 4 – Rated operating conditions; Design
  • Page 5 – Displays and controls; Certificates and approvals
  • Page 6 – Communication
  • Page 7 – Example for ordering:; Ordering data; Order code
  • Page 10 – Connection; Please add
  • Page 11 – Dimensional drawings; Connection to ANSI B16.5; Effective diaphragm diameter
Loading the manual

Siemens FI 01 · 2000

1/42

SITRANS P

Introduction

Transmitters for level

Application

The SITRANS P transmitter with mounting flange measures the
level of corrosive and non-corrosive liquids in open and closed
containers. Different spans are possible depending on the ver-
sion.

The nominal mounting flange diameter is DN 80 or DN 100, or
3 or 4 inches.

In the case of level measurements in open containers, the low-
pressure connection of the measuring cell remains open (mea-
surement with respect to atmosphere), while for measurements
in closed containers, this connection must be connected to the
container in order to compensate the static pressure.

The wetted parts are constructed from a variety of materials de-
pending on the degree of corrosion resistance required (see
Technical data).

The output signal is a load-independent direct current of 4 to
20 mA linearly proportional to the level (hydrostatic pressure), or
a digital bus signal.

Transmitters conforming to the type of protection "Intrinsic safe-
ty" and "Explosion-proof" may be installed within potentially ex-
plosive atmospheres (zone 1). The conformity certificate
corresponds to the European standard (CENELEC).

Adjustable spans

Types of protection and conformity certificates

4

Exists

Fig. 1/23 SITRANS P transmitters for level, with built-in analog indicator or digital display

Series

Span in mbar

25

to

5,000

HK

DS

DS (PA)

Measuring cells from 250 to 5,000 mbar

Series

Type of protection

Conformity certificate

Intrinsic
safety

Explosion-
proof

CENELEC

FM/CSA

HK

4

4

DS

4

4

4

DS (PA)

4

4

4

Fig. 1/24 Functional diagram

4

6

9

-

5

7

8

3

2

1

+

10

15

17

00 00000

M

16

,

11

12

13

14

I A U H

C

m

M

16

00000

00

18

17

HK series

DS series

+

Differential pressure

-

as input variable

I

A

Output signal

U

H

Power supply

1 Seal diaphragm of

mounting flange

2 Flange with tube
3 Capillary with filling liquid

of mounting flange

4 Seal diaphragm of meas. cell

5 Measuring cell body
6 Overload diaphragm
7 Silicon pressure sensor
8 O-ring

}

9 Process flange

10 Filling liquid of measuring cell
11 Instrument amplifier
12 Analog-to-digital converter
13 Microcontroller
14 Digital-to-analog converter or

PROFIBUS-PA interface

15 Digital display for

parameterization

16 Keys for parameterization
17 Analog indicator (option)
18 Digital display for parameter-

ization and measured value

HK series

DS series

Fi01_e_K01_S34-43.fm Seite 42 Freitag, 17. Dezember 1999 2:32 14

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SITRANS P; Transmitters for level; Introduction; Mode of operation; Parameterization using

Siemens FI 01 · 2000 1/43 SITRANS P Transmitters for level Introduction ■ Mode of operation The input pressure (hydrostatic pressure) acts on the measuring cell via the seal diaphragm (1, Fig. 1/24) of the mounting flange. The differential pressure present on the measuring cell is ap-plied via the s...

Page 3 - Technical data; Application

Siemens FI 01 · 2000 1/44 SITRANS P Technical data Transmitters for level SITRANS P ■ Technical data *) 0.4 instead of 0.2 and 0.3 instead of 0.15 for 10 < r ˆ 30. HK7MF4620 DS7MF4632 DS with PROFIBUS-PA7MF4632 Application See page 1/42 Mode of operation Measuring principle See page 1/43 Piezo-re...

Page 4 - Rated operating conditions; Design

Siemens FI 01 · 2000 1/45 SITRANS P Transmitters for level Technical data ■ Technical data HK7MF4620 DS7MF4632 DS with PROFIBUS-PA7MF4632 Rated operating conditions Installation conditions • Installation instructions Mounting position dependent on flange Ambient conditions • Ambient temperature (obs...

Other Siemens Models