1/28
SITRANS P
Introduction
Transmitters for differential pressure and flow
■
Application
The transmitter measures
• the differential pressure,
• low pressures above or below atmospheric pressure,
• the flow q ~
(in conjunction with a primary differential
pressure device)
of gases, vapors and liquids. Different spans are possible de-
pending on the version.
The output signal is a load-independent direct current of 4 to
20 mA or a digital bus signal where a linear characteristic (pro-
portional to the differential pressure) or a square-rooted charac-
teristic (proportional to the flow) can be selected.
Transmitters conforming to the type of protection "Intrinsic safe-
ty" and "Explosion-proof" may be installed within potentially ex-
plosive atmospheres (zone 1). The conformity certificate
corresponds to the European standard (CENELEC), the Ameri-
can standard (FM) or the Canadian standard (CSA).
The transmitters can be equipped with various designs of re-
mote seals for special applications such as the measurement of
highly viscous substances.
■
Adjustable spans
■
Types of protection and conformity certificates
Fig. 1/16 SITRANS P transmitters for differential pressure and flow, with built-in analog indicator or digital display
D
p
Series
Span in bar
1
to
30,000
HK
DS
DS (PA)
Measuring cells from 20 mbar to 30 bar
Series
Type of protection
Conformity certificate
Intrinsic
safety
Explosion-
proof
CENELEC
FM/CSA
HK
4
4
DS
4
4
4
4
DS (PA)
4
4
4
o
4
= Exists
o
= In planning
Fig. 1/17 Functional diagram
5
7
1
6
4
3
+
-
2
4
,
8
9
10
11
I A U H
C
12
14
00 00000
M
00000
00
15
M
13
13
m
14
HK series
DS series
+
Differential pressure
-
as input variable
I
A
Output signal
U
H
Power supply
1 Process flange
2 Body of measuring cell
3 Filling liquid
4 Seal diaphragm
5 O-ring
6 Center diaphragm
7 Silicon pressure sensor
8 Instrument amplifier
9 Analog-to-digital converter
10 Microcontroller
11 Digital-to-analog converter or
PROFIBUS-PA interface
12 Digital display for
parameterization
13 Keys for parameterization
14 Analog indicator (option)
15 Digital display for
parameterization
and measured value
}
HK series
DS series with
PROFIBUS-PA
Fi01_e_K01_S22-33.fm Seite 28 Freitag, 17. Dezember 1999 2:35 14
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Siemens FI 01 · 2000 1/29 SITRANS P Transmitters for differential pressure and flow Introduction ■ Mode of operation The differential pressure is applied via the seal diaphragm (4, Fig. 1/17) and the filling liquid (3) to the silicon pressure sensor (7). If the measuring limits are exceeded, the ove...
Siemens FI 01 · 2000 1/30 SITRANS P Technical data Transmitters for differential pressure and flow ■ Technical data HK7MF4420, MF4520 DS7MF4432, 7MF4532 DS with PROFIBUS-PA7MF4432, 7MF4532 Application See page 1/28 Mode of operation Measuring principle See page 1/29 Piezo-resistive Input Measured va...
Siemens FI 01 · 2000 1/31 SITRANS P Transmitters for differential pressure and flow Technical data ■ Technical data HK7MF4420, MF4520 DS7MF4432, 7MF4532 DS with PROFIBUS-PA7MF4432, 7MF4532 Accuracy (continued) Influence of static pressure • On start-of-scale value 0.15 % per 100 bar at max. span; ...