Page 2 - Thank-you for purchasing a; REGENCY FIREPLACE PRODUCT; Keep those; REGENCY FIRES
I1200 Regency Wood Insert 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGE...
Page 3 - TABLE OF CONTENTS
I1200 Regency Wood Insert 3 TABLE OF CONTENTS SAFETY LABEL Safety Label .................................................................. 4 UNIT DIMENSIONS With Standard Flue Adaptor .......................................... 5With Offset Flue Adaptor ..................................................
Page 4 - SAFETY LABEL; CAUTION
I1200 Regency Wood Insert 4 SAFETY LABEL This is a copy of the label that accompanies each I1200S Wood Insert . We have printed a copy of the contents here for your review. LISTED F ACT OR Y BUIL T FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U.S.A. MODEL: I1200S TESTED T O : ULC S628-M93 / UL 1...
Page 5 - UNIT DIMENSIONS; WITH STANDARD FLUE ADAPTOR
I1200 Regency Wood Insert 5 UNIT DIMENSIONS WITH STANDARD FLUE ADAPTOR 6" (152mm) Diameter STANDARD FLUE ADAPTOR (171-932)
Page 6 - WITH OFFSET FLUE ADAPTOR
I1200 Regency Wood Insert 6 UNIT DIMENSIONS WITH OFFSET FLUE ADAPTOR 6" (152mm) Diameter OFFSET FLUE ADAPTOR (171-936)
Page 7 - INSTALLATION; Requirements for Installing
I1200 Regency Wood Insert 7 INSTALLATION CHIMNEY SPECIFICATIONS Before installing, check and clean your chimney system thoroughly. If in doubt about its condi-tion, seek professional advice. Your Regency Insert is designed for installation into a masonry fi replace that is constructed in accordance w...
Page 8 - MASONRY AND FACTORY BUILT FIREPLACE CLEARANCES; Floor Protection
I1200 Regency Wood Insert 8 Clearance diagram for installations INSTALLATION Side and Top facing is a maximum of 1.5" thick. Floor protection must non-combustible, insulative material with an R value of 1.1 or greater. * If the hearth extension is fl ush with the fl oor (F) it must extend 19.5"...
Page 9 - INSTALLING
I1200 Regency Wood Insert 9 INSTALLATION INSTALLING YOUR INSERT SAFETY NOTE: The insert is very heavy and will require two or three people to move it into position. The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges. Be sure to protect ...
Page 10 - INSTALLATION INTO A
I1200 Regency Wood Insert 10 1) Positive Flue Connection with Cleanout INSTALLATION 2) Direct Flue Connection with Cleanout 3a) Full Flue Liner (No Cleanout Required) Note: A c l e a n - o u t d o o r i s s o m e t i m e s required, by your inspector, to be installed when either the Positive fl ue co...
Page 11 - BOTTOM FACEPLATE & FAN SUPPORT INSTALLATION; Optional; Regular/Oversize Bottom Faceplate; If the insert is going to sit on the hearth
I1200 Regency Wood Insert 11 INSTALLATION FACEPLATE, TRIM & OPTIONAL BOTTOM FACEPLATE & FAN SUPPORT INSTALLATION Regular/Oversize Faceplate Installation: 1) Thread the black 1/4" x 3/4" long hex bolts into the faceplate mount-ing bracket as shown in Diagram 1, leaving them approximat...
Page 12 - Regular/Oversize Faceplate Trim Installation:; Fan Support Installation:
I1200 Regency Wood Insert 12 8) Measure the total height of the faceplate assembly and cut both the left and right side trim accordingly using a metal cutting blade. 9) Assemble the left and right side trim to the top trim using the trim clips provided as shown in Diagram 5. 10) Fit the trim assembl...
Page 13 - Completed Faceplate Assembly
I1200 Regency Wood Insert 13 15) Cut the bottom edge of the fan support (using a metal cutting blade) to the length measured in step 14. 16) Remove the fan assembly from the ash lip of the insert and position the fan support to the bottom of the fan assembly. 17) Drill 4 x 5/32" holes to the und...
Page 15 - FIREBRICK ASSEMBLY; DRAFT CONTROL
I1200 Regency Wood Insert 15 BRICK FLUE BAFFLE &SECONDARY AIR TUBE INSTALLATION The fl ue baffl e system located in the upper area of the fi rebox is removable to make cleaning your chimney system easier. The brick baffl es must be installed prior to your fi rst fi re. Smoke spillage and draft problem...
Page 16 - FIRST FIRE
I1200 Regency Wood Insert 16 INSTALLATION FIRST FIRE When your installation is completed and in-spected, you are ready for your fi rst fi re. 1) Open draft control fully. 2) Open fi rebox door and build a small fi re using paper and dry kindling, wait a few minutes for a good updraft in the fl ue to esta...
Page 17 - CREOSOTE; Removal for Cleaning etc.; OPERATING INSTRUCTIONS; FAN OPERATION; ASH DISPOSAL
I1200 Regency Wood Insert 17 15) Do not store any fuel closer than 2 feet from your unit. 16) Do not burn salt drift wood as it will corrode your unit and void the warranty. 17) Do not strike or slam the glass door shut as this may cause the glass to break. 18) Do not operate the unit if the glass i...
Page 18 - MAINTENANCE
I1200 Regency Wood Insert 18 3) Only burn seasoned wood! Avoid burning wet or green wood. Seasoned wood has been dried at least one year. 4) A small hot fi re is preferable to a large smouldering one that can deposit creosote within the system. 5) Check the chimney at least twice a month during the b...
Page 19 - MAIN ASSEMBLY; PARTS LIST
I1200 Regency Wood Insert 19 MAIN ASSEMBLY Part # Description 850-141 Black Door - Complete 850-142 Gold Door - Complete 850-143 Nickel Accent Door - Complete 850-144 Gold Accent Door - Complete 2) 846-302 Glass - Replacement 4) 936-243 7/8" Adhesive Tape Gasket 5) 846-920 Glass Retainer Clips (...
Page 20 - FACEPLATES
I1200 Regency Wood Insert 20 PARTS LIST FACEPLATES Part # Description 171-920 Faceplate & Trim Set - Regular - Black 171-924 Trim Set - Regular Brass 171-922 Faceplate & Trim Set - Oversize - Black 171-926 Trim Set - Oversize Brass 171-928 Bottom Piece and Fan Support - Regular 171-930 Botto...
Page 21 - FIREBRICK
I1200 Regency Wood Insert 21 PARTS LIST FIREBRICK Part # Description 170-960 Complete Brick Set 70) * Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 76) * Brick Partial: 1-1/4" x 2" x 9" 81) * Brick Partial: 1-1/4" x 1-1/4" x 9" 84) * Brick Partial: 1-1/4" x 4-...
Page 22 - NOTES
Page 23 - WARRANTY
I1200 Regency Wood Insert 23 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend th...
Page 24 - Printed in Canada
Printed in Canada Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _______...