Page 2 - INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FIREPLACE PRODUCTS INTERNATIONAL. The G36D is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a w...
Page 3 - TABLE OF CONTENTS; OPERATING INSTRUCTIONS
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 3 TABLE OF CONTENTS OPERATING INSTRUCTIONS Operating ....................................................................34 Instructions ..................................................................34 Lighting Procedure ....................
Page 4 - SAFETY LABEL; Copy of Safety Decal for G36D-NG1; Duplicate
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 4 This is a copy of the label that accompanies each G36D Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, visible when...
Page 5 - INSTALLATION
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 5 INSTALLATION CHECKLIST 1) Check all clearances to combustibles. Refer to the following sections: a) Locating Your Gas Stove b) Clearances c) Mantel Leg Clearances d) Combustible Mantels e) Framing and Finishing f) Hearth Requirement 2) Asse...
Page 7 - Fire hazard is an extreme risk if
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 7 MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram below: FRAMING AND FINISHING 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the fro...
Page 8 - COMBUSTIBLE MANTELS
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 8 INSTALLATION COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be ...
Page 9 - Top Standoff Assembly; VENTING
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 9 "C" Screw Position: For a facing material depth of 1-1/4" (32mm), the top facing support must be reversed. UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be corre...
Page 10 - EXTERIOR VENT TERMINATION LOCATIONS
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 10 INSTALLATION EXTERIOR VENT TERMINATION LOCATIONS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openabl e N L B E B M D F K H j V ertical Termination V V ent terminal Area where terminal is not permited A Air supp...
Page 11 - UltraGlow
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 11 VENTING UltraGlow ® UltraGlow UltraGlow Direct Vent System (Flex) ® ® Horizontal Terminations Only These venting systems, in combination with the G36D Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by...
Page 12 - RIGID PIPE VENTING COMPONENTS LIST
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 12 INSTALLATION FPI 946-506/P Vent Guard (Optional) 510-994 Rigid Pipe Adaptor (Must use with all Rigid Piping) 640-530/P Riser Vent Terminal 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-208/P Vent Guard (Optional) - Riser Vent...
Page 13 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations; Alternate
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 13 Rigid Pipe Adaptor (Part# 510-994) Pipe Length Vertical Terminal Storm Collar (Part # 953) Flashing 943 or 943S Ceiling Firestop (Part # 963) 24" Pipe Length Adj.Pipe Length 11" - 14-5/8" 90 Elbow o Horizontal Termination Cap (...
Page 14 - RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 14 RIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS UltraGlow ® UltraGlow UltraGlow DIRECT VENT SYSTEM (FLEX) ® ® (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminati...
Page 16 - RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 16 RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS (Propane & Natural Gas) The G36D is approved for a maximum 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using two 90 o elbows (two 45 o elbows equal ...
Page 18 - VERTICAL TERMINATION
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 18 INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the full length of the chimney. See the Venting Arrangements on next page for ...
Page 19 - VENTING ARRANGEMENTS - VERTICAL TERMINATIONS; with Co-linear Flex System for both
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 19 INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations.
Page 20 - Below Grade Installation; UNIT INSTALLATION
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 20 6) The arrow on the vent cap should be pointing up. Insure that the 1-1/2" clearances to combustible materials are maintained (Diagram 4). Install the termination cap. NOTE: For Snorkel terminations in ABOVE grade installations, fo...
Page 22 - Offset Chart; for UltraGlow
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 22 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip insid...
Page 23 - G36D-NG1 System Data
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 23 INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to ...
Page 24 - THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 24 CONVERSION KIT #773-969 FROM NG TO LPG FOR G36D-1 USING SIT 820 NOVA GAS VALVE INSTALLATION THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply Shut of Shut of . 2)...
Page 25 - Do not overtighten the screw; Installation of the DC Sparker:
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 25 INSTALLATION 20) Replace yellow "Natural Gas" label with red "Propane" label. WARNING! Do not overtighten the screw Recommended to grip the wrench by the short side. 16) Verify that if the conversion is from V V NG to LPG, ...
Page 27 - LOG SET INSTALLATION
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 27 5) Position Log 02-53 across the cutouts in Logs 02-75 and 02-51 with the notch on the left side of the log fi tting into the 2nd grate tab. Cutouts 2nd Grate Tab LOG SET INSTALLATION Read the instructions below carefully and refer to the d...
Page 30 - Flush Louvers; STANDARD FLUSH; Optional Flush Trim
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 30 Diagram 3 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket. Repeat for 2nd spring. See diagram 3. Diagram 2 Be careful that the glass gasket does not roll up; there must be a gap b...
Page 31 - Thermostat Wire Table; WALL THERMOSTAT; REMOTE CONTROL; CAUTION
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 31 Thermostat Wire Table Option 3: WALL THERMOSTAT A wall thermostat may be installed if desired, connect the wires as per the wiring diagram. Use the table below to determine the maximum wire length. Note: Preferable if the thermostat is ins...
Page 32 - WIRING DIAGRAM; Caution: Ensure that the wires do; CAUTION: Label all wires prior
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 32 WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. (Do not cut the ground terminal off under ...
Page 33 - INSTALLING THE OPTIONAL FAN; To Remove the Fan
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 33 120 Volt AC power is needed for the fan switch and blower. A three wire power cord is provided to be plugged into the receptacle. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. 1) Shut the p...
Page 34 - DO NOT ATTEMPT; IMPORTANT; DO NOT BURN THE APPLIANCE
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 34 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no...
Page 35 - TO TURN OFF GAS APPLIANCE; DO NOT REMOVE THIS INSTRUCTION PLATE
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 35 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs...
Page 36 - MAINTENANCE; General Vent Maintenance; OR BRASS TRIM; Flush Glass Replacement
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 36 MAINTENANCE 4) Make a periodic check of burner for proper position and condition. Visually check the fl ame of the burner periodically, making sure the fl ames are steady; not lifting or fl oating. If there is a problem, call a qualifi ed ...
Page 37 - INSTALLING VALVE; REMOVING VALVE; Verify proper operation
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 37 13) Undo the pilot tube from the valve with a 7/16" wrench. 14) Undo the quick drop out thermocouple nut on the valve with a 9mm (metric) wrench. 15) Remove the Piezo ignitor wire and push button assembly. 16) Undo the "gas out"...
Page 38 - G36D MAIN ASSEMBLY
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 38 G36D MAIN ASSEMBLY Part # Description 1) 948-253 Door Handle 2) 510-026 Hinge Bracket - Left/Right 3) 948-045 Chain 4) 948-115 Spring 6) 430-129 Receptacle Box Mount 7) 910-429 Box - Receptacle 8) 910-428 Duplex Receptacle 9) 910-430 C...
Page 39 - G36D BURNER ASSEMBLY & LOG SET; PARTS LIST
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 39 G36D BURNER ASSEMBLY & LOG SET Part # Description 52) 910-190 Piezo Ignitor & Nut 53) 780-021 Gasket - Valve Access Plate NG/LP 786-574/P Valve Assy - Natural Gas 786-576/P Valve Assy - Propane 56) * Valve Tray - NG/LP 57) 910-378 ...
Page 40 - G36D FLUSH FRONT ASSEMBLY
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace ® ® 40 G36D FLUSH FRONT ASSEMBLY 131) 510-934 Flush Glass Trim (Set) - Brass 510-947 Flush Glass Trim (Set) - Steel 510-932 Flush Glass Trim (Set) - Gold 132) 904-196 Magnet (1" Round) 133) 780-069 Flush Louver - Top - Black 134) 786-520 ...
Page 41 - NOTES
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 41 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ _________________________...
Page 43 - WARRANTY
UltraGlow ® G36D Zero Clearance Direct Vent Gas Fireplace 43 WARRANTY UltraGlow ® UltraGlow UltraGlow products, are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully ® ® inspects each unit thoroughly before it leaves our door. UltraGlow ® in...
Page 44 - Installer: Please complete the following information; Register your UltraGlow
UltraGlow G36D Zero Clearance Direct Vent Gas Fireplace 44 Installer: Please complete the following information Dealer Name & Address: _________________________________________________________________________________________________________________Installer: _____________________________________...