Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 2 To the New Owner: Congratulations!You are the owner of a state-of-the-art Gas Fireplace by REGENCY. The P48-1 hasbeen designed to provide you with all the warmth and charm of a wood fireplace atthe flick of a switch. The model P48-1 has been a...
Page 3 - TABLE OF CONTENTS; Page
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 3 TABLE OF CONTENTS Flush Trim ................................................................. 28Bay Door ................................................................... 29Bay Trim .............................................................
Page 4 - SAFETY LABEL; Copy of Safety Decal for P48-NG1 and P48-LP1
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 4 This is a copy of the label that accompanies eachP48-NG1 and P48-LP1 Zero Clearance DirectVent Gas Fireplace. We have printed a copy ofthe contents here for your review. The safetylabel is located on the front inside base of theunit, visible w...
Page 5 - INSTALLATION
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 5 INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The P48-NG1/P48-LP1 Direct Vent Fireplacemust be installed in accordance with these in-structions. Carefully read all the instructions inthis manual first. Consult the "authority havingjurisd...
Page 7 - Heat Release Kit; CLEARANCES
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 7 INSTALLATION The HeatWave Duct Kitand the Heat ReleaseKit have different clear-ance and framin require-ments, check the Heat-Wave and Heat Releasemanual for details. Heat Release Kit CLEARANCES The clearances listed below are Minimum distances...
Page 8 - MANTELS; MANTEL LEG CLEARANCES
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 8 MANTELS Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from louver areshown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the fra...
Page 9 - IMPORTANT
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 9 INSTALLATION Note: 43" (1092mm) is the minimum height for flex termination and Simpson Dura-Vent terminations. Diagram 1 1 ) Determine the total thickness of facing material (eg. drywall plus ceramic tiles) to allow the finished surface to...
Page 10 - VENTING; UNIT ASSEMBLY; Top Standoff Assembly; Top Facing Support and
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 10 VENTING INTRODUCTION The P48-1 uses the "balanced flue" tech-nology Co Axial system. The inner liner ventsproducts of combustion to the outside while theouter liner draws outside combustion air intothe combustion chamber thereby elimi...
Page 11 - EXTERIOR VENT TERMINATION REQUIREMENTS
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 11 INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D F K H j V ertical T ermination V V ent terminal Area where terminal is not permited A Air supply o...
Page 12 - Regency Direct Vent System (Flex) Horizontal
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 12 VENTING Regency Direct Vent System (Flex) Horizontal Terminations Only These venting systems, in combination with the P48-1 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system byWarnock Hersey. The location o...
Page 13 - Horizontal or Vertical Terminations; Flat Wall Installation; none; Alternate; SIMPSON DURA-VENT VENTING
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 13 INSTALLATION SIMPSON DURA-VENT VENTING Horizontal or Vertical Terminations The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations.Many items are offere...
Page 14 - VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS; SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 14 INSTALLATION VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and REGENCY DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizonta...
Page 15 - Option V; Elbows; Option H; Option H
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 15 INSTALLATION Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 1' Min. 3' Max. B) 2' Min. 4' Max. C) 3' Min. 5' Max. D) 4' Min. 6' Max. E) 5' Min. 7' Max. F) 6' Min. 8' Max. Horizontal Venting with Two (2) 90 o Elbows Option H V ...
Page 16 - Option V
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 16 INSTALLATION Horizontal Venting with Three (3) 90 o Elbows Option V H V + V1 H + H1 A) 2' Min. 1' Max. 3' Min. 4' Max. B) 3' Min. 2' Max. 4' Min. 5' Max. C) 4' Min. 3' Max. 6' Min. 6' Max. D) 5' Min. 4' Max. 8' Min. 7' Max. E) 6' Min. 5 Max. ...
Page 17 - Option V; Option
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 17 INSTALLATION Vertical Venting with Three (3) 90 o Elbows Option V H + H1 V + V1 A) 2' Min. 3' Max. 4' Min. B) 3' Min. 4' Max. 6' Min. C) 4' Min. 5' Max. 7' Min. D) 5' Min. 6' Max. 8' Min. E) 6' Min. 7' Max. 9' Min. F) 7' Min. 8' Max. 10' Min....
Page 18 - VENTING ARRANGEMENTS - VERTICAL TERMINATIONS; SIMPSON DURA-VENT DIRECT VENT GS SYSTEM
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 18 INSTALLATION • Vent must be supported at offsets. • Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles. Note: Must use optional flue adapter when using Simpson Dura-Vent pipe ...
Page 20 - HORIZONTAL
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 20 Diagram 7 Diagram 6 9 ) Install wall thimble in the center of the 11" (279mm) square and attach with woodscrews (Diagram 7). Diagram 5 6 ) The arrow on the vent cap should be pointing up. Insure that the 1-1/4"(32mm)clearances to comb...
Page 21 - VERTICAL; Offset Chart
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 21 INSTALLATION 6 ) Continue to assemble pipe lengths. Note: If an offset is necessary in the attic to avoid obstructions, it is impor-tant to support the vent pipe every3 feet (0.9 meter), to avoid exces-sive stress on the elbows, andpossible s...
Page 22 - for Regency Direct Vent
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 22 INSTALLATION 4 ) Separate the 2 halves of the wall thimble and securely fasten the one with the tabsto the outside wall making sure that the tabsare on top and bottom. Fasten the otherthimble half to the inside wall. The thimblehalves slip in...
Page 24 - BRICK PANELS INSTALLATION
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 24 BRICK PANELS INSTALLATION INSTALLATION 1 ) Unhook the 2 spring loaded hooks from the bottom of the flush door and lift the Flush Front off the unit. 2 ) Unwrap the brick pattern panels from the protective wrapping. Note: The logs must not be ...
Page 25 - LOG SET INSTALLATION
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 25 Read the instructions below carefully and refer to the diagrams.If logs are broken do not use the unit until they are replaced.Broken logs can interfere with the pilot operation. The gas log kit (Part # 370-930) contains the following pieces:...
Page 28 - STANDARD; FLUSH LOUVERS; Optional Flush Trim
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 28 INSTALLATION Diagram 1 Diagram 3 STANDARD FLUSH DOOR The standard flush door comes with a blackframe. To install the frame, simply hook the topdoor flange onto the top of the unit and swingthe door towards the unit, diagram 1. Diagram 2 NOTE:...
Page 29 - BAY LOUVERS; Optional Bay Trim; OPTIONAL BAY DOOR
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 29 BAY LOUVERS 1 ) Install top louver by sliding the two bracket clips into the brackets located on top of thebay door. See below. The fitted louverleaves a small gap between faceplatebottom and louver top. Diagram 4 Diagram 3 Optional Bay Trim ...
Page 30 - OPTIONAL FINISHING TRIM; DOUBLE SCREEN
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 30 OPTIONAL FINISHING TRIM NOTE: Remove both the Flush Louvers or Bay Louvers and the Flush Front or Bay Front priorto installing the Finishing Trim. 1 ) Install the Finishing Trim sides as shown in the diagram, line up the holes in the side tri...
Page 31 - Thermostat Wire Table; WALL THERMOSTAT; REMOTE CONTROL
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 31 Can be used with Option 1 or 3 but not both. 1 ) Run the supplied 15' of wire through the back gas inlet opening. Be careful not todamage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with alonger run, use the Thermo...
Page 32 - WIRING DIAGRAM
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 32 INSTALLATION WIRING DIAGRAM CAUTION: Label all wiresprior to disconnectionwhen servicing controls.Wiring errors can causeimproper and dangerousoperation. No electrical power supply is required for thegas control to operate. 120 Volt AC power ...
Page 33 - INSTALLING THE OPTIONAL FAN; To Remove the Fan
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 33 INSTALLATION INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switchand blower. The fan can be hard wired ifdesired. The receptacle box should be installedon the left hand side of the unit by a qualifiedelectrician. The neu...
Page 34 - CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #370-969
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 34 CONVERSION KIT FROM NATURAL GAS TO PROPANE MODEL #370-969 FOR P48-1 USING SIT 820 NOVA GAS VALVE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 5 ) Pull off the pilot cap to expose thepilot ori...
Page 35 - OPERATING INSTRUCTIONS
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 35 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1 ) Read and understand these instructions before operating this appliance. 2 ) Check to see that all wiring is correct and enclosed to prevent possible shock. 3 ) Check to ensure there are no gas...
Page 36 - Copy of the Lighting Plate Instructions; NORMAL OPERATING
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 36 Copy of the Lighting Plate Instructions NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some soundsfrom your gas appliance. This is perfectlynormal due to the fact that there are variousgauges and types of steel us...
Page 37 - General Vent Maintenance; MAINTENANCE
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 37 LOG REPLACEMENT The unit should never be used with broken logs.Turn off the gas valve and allow the unit to coolbefore opening door and carefully remove thelogs. (The pilot light generates enough heat toburn someone.) If for any reason a log ...
Page 38 - Bay Glass Replacement; DOOR GLASS; GLASS REPLACEMENT; INSTALLING VALVE
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 38 CAUTION: Wear gloves when re-moving damaged or broken glass. Bay Glass Replacement 1 ) Remove the door from the unit and place on a soft surface to prevent scratching. 2 ) Remove the nuts holding the glass clips in place and remove. 3 ) Repla...
Page 39 - REMOVING VALVE
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 39 MAINTENANCE 6 ) Remove the burner by removing the screw on the left side and then slide the burner tothe left and lift out. 7 ) Remove the right and left side deflectors by removing the 2 screws on each deflector. REMOVING VALVE 1 ) Shut off ...
Page 40 - PARTS LIST
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 40 PARTS LIST P48-1 MAIN ASSEMBLY Part # Description Part # Description 1 ) 948-259 Door Handle 3 ) 948-046 Chain 4 ) 948-115 Spring 6 ) 430-129 Receptacle Box Mount 7 ) 910-429 Box - Receptacle 8 ) 910-428 Duplex Receptacle 9 ) 910-430 Cover - ...
Page 45 - NOTES
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 45 NOTES _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ ______________________________...
Page 47 - WARRANTY
Regency P48-1 Zero Clearance Direct Vent Gas Fireplace 47 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects eachunit thoroughly before it leaves our facility. FPI Fireplace Products Internatio...
Page 48 - Installer: Please complete the following information; Printed in Canada