Raypak 1802B - Manual

Raypak 1802B

Raypak 1802B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
Page: / 3
Loading the manual

Catalog No.: 6000.342D

Effective: 9-01-09

Replaces: 6-22-08

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

MBTUH Input:


Sealed Combustion Chamber
100% Factory Fire Tested
Efficiency: 85%
Minimum Non-condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-year Thermal Shock Warranty
Limited Five-year Heat Exchanger Warranty
Full Safety Diagnostics with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-assisted
Non-ferrous Bypass
Patented Burner Security Blanket


Heat Exchanger

ƒ

Brass

Headers

ƒ

ASME Inspected and Stamped

160 PSIG Working Pressure

ƒ

National Board Approved

ƒ

Cupro Nickel Finned Tubing

ƒ

ASME Steel Tube Sheet

ƒ

Silicone High Temp O-Rings

ƒ

125 PSIG ASME Pressure Relief Valve

ƒ

Temperature and Pressure Gauge

ƒ

Water

Connections

Left – Standard
Right – Option A-6

ƒ

Bronze Pump, 120V, 60Hz

ƒ

Non-ferrous Pool Bypass

Controls

ƒ

120V, 60Hz, 1

Power Supply

ƒ

120/24V 60Hz Transformer

ƒ

100%

Shut-off/Lockout

ƒ

Hot Surface Ignition Systems (2)

ƒ

Remote Flame Sensors (2)

ƒ

High Limit Control, Auto Reset

ƒ

On/Off Power Switch

ƒ

Manual Shut-off, Front-mounted

ƒ

Flow

Switch

ƒ

Blocked Vent Pressure Switch

ƒ

Combustion Air Proving Switches

ƒ

Economaster Pump Time Delay

ƒ

Poolstat

ƒ

Diagnostic Panel with LCD Display

2 Lines, 20 Characters


Gas Train

ƒ

Combination

Valves

ƒ

On/Off

Firing

ƒ

Low Gas Pressure Switch, Manual

ƒ

Fuel

Natural Gas
Propane Gas

ƒ

Design Certified ANSI Z21.56/

CSA 4.7 (P models)

ƒ

Design Certified ANSI Z21.10.3/

CSA 4.3 (WHP models)

Burner

ƒ

Ultra-low

NOx:

Less than 20 PPM

Construction

ƒ

Indoor/Outdoor

Construction

ƒ

Enclosed Front Controls

Venting

ƒ

Vent

Location

Top – Standard
Rear – Option D-14

ƒ

Vent Termination Cap

Outdoor – Option D-11
Indoor, Horizontal –

Option D-15

Indoor, Vertical (by others)

ƒ

Combustion

Air

In-Line Filter Kit (TruSeal

only) – Option D-17

Air Intake Elbow –

Option D-16


Options

C-6

Ignition Module, Manual Reset

D-21 TruSeal™ Direct Vent

Right Side

Left Side (Model 1802B

Only)

F-10 Low Water Cut-off, Remote

Probe

P-__ Cold Water Run System

(See Page 3)

S-2

Dual High Gas Pressure
Switches, Manual Reset

X-1

SureRack Kit

X-2

SureRack Kit Above Grade
Add-on (used with X-1)

Y-241 Temperature Controller,

1-4 Stages

Regulatory Agency Requirements

G-1

CSD-1







Hi Delta

®

- Type P

Commercial Pool Heaters

Models 1802B-2342B

Standard “H” Bypass Shown

Patent No. 7,044,124

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Raypak Models

All Raypak Other